Northlake 635(2)-LR 970516 (5)Maxi 25' TECHNOLOGIES INC CLIENT: PROJECT: REPORT OF CONCRETE COMPRESSIVE STRENGTH Lincoln Property Co. 500 N. AKARD, SUITE 3300 ATTN: LARRY MOON Dallas, TX 75201 PROJECT NO.: 0903 REPORT NO.: 1155( COPPELL BUSINESS CENTER DATE OF SERVICE: 4 WRANGLER DR. & BELTLINE RD. AUTHORIZATION: Ct COPPELL, TX REPORT DATE: 5/] PAGE 1 Of 8 SERVICES: Test compressive strength specimens prepared in conjunctJ inspection. CONTRACTOR: BUTLER CONSTRUCTION CONCRETE SUPPLIER: PIONEER PLANT: 29 SPECIFICATION REQUIREMENTS STRENGTH: 4000psi @ 28 SLUMP: 5" METHOD OF TEST SAMPLING: ASTM C-172 MOLDING & CURING: ASTM C31 SLUMP: ASTM C143 TEMPERATURE: ASTM C-138 AIR CONTENT: N~A UNIT WEIGHT: N/A CAPPING/PADS: ASTM C617 TESTING: ASTM C39 DAYS CYLINDER MARKED SET NO. 1 1 1 2 1 3 1 4 PROJECT DATA MIX DESIGN NUMBER: 934~. DATE OF PLACEMENT: 4/~ TIME SAMPLED: 05: 15AM TEMPERATURE (DegF) - AIR: TRUCK NO: 133 MEASURED SLUMP (in.): 8. AIR CONTENT(%): N/A LOCATION OF PLACEMENT: A/7.8 to 8 REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X DATE AGE TESTED {days) 4/25/97 7 4/25/97 7 5/16/97 28 5/16/97 28 DIAMETER (in.) 6.00 6.00 6.00 6.00 12 CYLINDERS MAXIMUM COMPRESSIVE AREA LOAD STRENGTH (sq.in.) {lbs. force) (psi) FF 28.27 98410 3480 Cf 28.27 94140 3330 C( 28.27 130080 4600 C( 28.27 126900 4490 ADDITIONAL COMMENTS: Note: Visual check on slump, too high, superintendent elect concrete. Technician: Phillip L. Forrest Technician Report Of Tests Continued On Page 2 Tech. · Southwestern Labs Lone Star Dr. · P.O. Box 224227 Dallas, Texas 75222 Telephone: (214) 631-2700 FAX: (214) 920-1891 505034 8 /18/97 .arlie 6/97 with concrete 8/97 BY: Phillip L. Forrest 8 CONCRETE: 72 TICKET NO: 366815 .0 UNIT WEIGHT(pcf): N/A IACTURE TYPE REMARKS ,NE ,NE ~NE ~NE .ed to place Our otterl and reports are for the exc Lm Ve kme of the client to whom they ate addressed and .hill not be reprodu~ ed except in full without the approval of the te~ting lal3oretory. The cma of ou~ name muir race ye our written approve. Our s' tefs lad reports 1001 LW apply only to the sample ta~ted and/or inspected, and ate not indicative of the quentitiel of apparently identical or e imilat products. Lincoln Property Co. PROJECT NO. 0903605034 DATE OF SERVICE: 4/18/97 REPORT OF CONCRETE COMPRESSIVE STRENGTH (Cont inued) CONTRACTOR: BUTLER CONSTRUCTION CONCRETE SUPPLIER: PIONEER PLANT: 29 SPECIFICATION REQUIREMENTS STRENGTH: 4000psi @ 28 DAYS SLUMP: 5" METHOD OF TEST SAMPLING: ASTM C-172 MOLDING & CURING: ASTM C31 SLUMP: ASTM C143 TEMPERATURE: ASTM C-138 AIR CONTENT: N~A UNIT WEIGHT: N/A CAPPING/PADS: ASTM C617 TESTING: ASTM C39 CYLINDER MARKED DATE SET NO. TESTED PROJECT DATA MIX DESIGN NUMBER: 9349 DATE OF PLACEMENT: 4/1 TIME SAMPLED: 06: 35AM TEMPERATURE (DegF) - AIR: 51 TRUCK NO: 756 MEASURED SLUMP (in.): 5.0 AIR CONTENT(%): N/A LOCATION OF PLACEMENT: B.5/8.5 REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS MAXIMUM COMPRESSIVE AGE DIAMETER AREA LOAD STRENGTH {days) {in.) {sq.in.) (lbs. force), (psi) FF 2 1 4/25/97 2 2 4/25/97 2 3 5/16/97 2 4 5/16/97 7 6.00 28.27 126670 4480 C¢ 7 6.00 28.27 127290 4500 CC 28 6.00 28.27 165000 5840 CC 28 6.00 28.27 153120 5420 CC Technician: Phillip L. Forrest Technician Report Of Tests Continued On Page 3 REPORT NO. 115568 PAGE 2 OF 8 SET NO. 2 3/97 BY: Phillip L. Forrest CONCRETE: 70 TICKET NO: 366834 UNIT WEIGHT(pcf): N/A ~CTURE TYPE REMARKS NE NE NE NE ~ters eld reports fu I without the approval of the te~t:r~ laooretory, the u~s o.. o~-? ,,,,,,= '"'~3' .... '= "-'-:--' -- ;imilar products. 1001 LW apply only to the sample te~ted and/or tr~pected, al3d ars not H3dlcatlVe ot t~t~ quantities or app~renzly Io~lnuua u. Lincoln Property Co. PROJECT NO. 0903605034 DATE OF SERVICE: 4/18/97 REPORT OF CONCRETE COMPRESSIVE STRENGTH (Continued) CONTRACTOR: BUTLER CONSTRUCTION CONCRETE SUPPLIER: PIONEER PLANT: 29 SPECIFICATION REQUIREMENTS STRENGTH: 4000psi @ 28 DAYS SLUMP: 5" METHOD OF TEST SAMPLING: ASTM C-172 MOLDING & CURING: ASTM C31 SLUMP: ASTM C143 TEMPERATURE: ASTM C-138 AIR CONTENT: N/A UNIT WEIGHT: N/A CAPPING/PADS: ASTM C617 TESTING: ASTM C39 CYLINDER MARKED DATE SET NO. TESTED PROJECT DATA MIX DESIGN NUMBER: 9349 DATE OF PLACEMENT: 4/1 TIME SAMPLED: 08:40AM TEMPERATURE (DegF) - AIR: 5 TRUCK NO: 760 MEASURED SLUMP (in.): 5.2 AIR CONTENT(%): N/A LOCATION OF PLACEMENT: D/6.3 REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS MAXIMUM COMPRESSIVE AGE DIAMETER AREA LOAD STRENGTH [days) {in.) [sq.in.I (lbs. force) (psi) FI~ 3 1 4/25/97 7 3 2 4/25/97 7 3 3 5/16/97 28 3 4 5/16/97 28 6.00 28.27 127480 4510 CC 6.00 28.27 127270 4500 CC 6.00 28.27 155670 5510 CC 6.00 28.27 147200 5210 CC ADDITIONAL COMMENTS: Eight gallons of water added at site. Technician: Phillip L. Forrest Technician Report Of Tests Continued On Page 4 REPORT NO. 115568 PAGE 3 OF 8 SET NO. 3 8/97 BY: Phillip L. Forrest CONCRETE: 73 TICKET NO: 366863 UNIT WEIGHT(pcf): N/A ACTURE TYPE REMARKS NE NE NE NE Our lettare ~ reports are for the exclusive use of the client to whom they e.-e addressed end shall not bo reproduc IKI except in full without the approval of I:he te~ting laboratory. The use ofoqr name must receive, our .written app¢~v, al.. O,ur iet :era and reports 1001 LW eppty or~ly to the sample teated and/or inspected, and are not indicative of the quantities or apparently ioentlcal or s miler pr(.:lucca, Lincoln Property Co. PROJECT NO. 0903605034 DATE OF SERVICE: 4/18/97 REPORT OF CONCRETE COMPRESSIVE STRENGTH (Continued) CONTRACTOR: BUTLER CONSTRUCTION CONCRETE SUPPLIER: PIONEER PLANT: 29 SPECIFICATION REQUIREMENTS STRENGTH: 4000psi @ 28 DAYS SLUMP: 5" METHOD OF TEST SAMPLING: ASTM C-172 MOLDING & CURING: ASTM C31 SLUMP: ASTM C143 TEMPERATURE: ASTM C-138 AIR CONTENT: N/A UNIT WEIGHT: N/A CAPPING/PADS: ASTM C617 TESTING: ASTM C39 CYLINDER MARKED DATE SET NO. TESTED PROJECT DATA MIX DESIGN NUMBER: 934! DATE OF PLACEMENT: 4/i TIME SAMPLED: 09: 32AM TEMPERATURE (DegF) - AIR: TRUCK NO: 100 MEASURED SLUMP (in.): 5. AIR CONTENT(%): N/A LOCATION OF PLACEMENT: E/6.3 to E/6.7 REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS MAXIMUM COMPRESSIVE AGE DIAMETER AREA LOAD STRENGTH {days) {in.) (sq.in.) (lbs. force) (psi) F 4 1 4/25/97 7 6.00 28.27 107970 3820 C~ 4 2 4/25/97 7 6.00 28.27 114320 4040 C~ 4 3 5/16/97 28 ~ 6.00 28.27 138440 4900 C~ 4 4 5/16/97 28 6.00 28.27 137480 4860 C~ ADDITIONALCOMMENTS: Five (5) gallons of water added at site. Technician: Phillip L. Forrest Technician Report Of Tests Continued On Page 5 REPORT NO. 115568 PAGE 4 OF 8 SET NO. 4 .8/97 BY: Phillip L. Forrest ,7 CONCRETE: 74 TICKET NO: 344150 [5 UNIT WEIGHT(pcf): N/A {ACTURE TYPE REMARKS )NE )NE )NE )NE Our le~;tem and reports are for the exclusive ues of the client to whom they ere addre~ed and shall not be, re?.~od~ ced except in full without the approval of the testing laboratory. The use of our name mu~t receive our written approval, uur ittar$ ~ reports 1001 LW apply only to the sample tested and/or inspected, arx:l are not indicative of the quantities of apparently identical or simitar products. Lincoln Property Co. PROJECT NO. 0903605034 DATE OF SERVICE: 4/18/97 REPORT OF CONCRETE COMPRESSIVE STRENGTH (Cont i nued) CONTRACTOR: BUTLER CONSTRUCTION CONCRETE SUPPLIER: PIONEER PLANT: 29 SPECIFICATION REQUIREMENTS STRENGTH: 4000psi @ 28 DAYS SLUMP: 5" METHOD OF TEST SAMPLING: ASTM C-172 MOLDING & CURING: ASTM C31 SLUMP: ASTM C143 TEMPERATURE: ASTM C-138 AIR CONTENT: N/A UNIT WEIGHT: N/A CAPPING/PADS: ASTM C617 TESTING: ASTM C39 PROJECT DATA MIX DESIGN NUMBER: 934cj DATE OF PLACEMENT: 4/1 TIME SAMPLED: 10: 30AM TEMPERATURE (DegF) - AIR: 7 TRUCK NO: 551 MEASURED SLUMP (in.): 4, AIR CONTENT(%): N/A LOCATION OF PLACEMENT: E.5/7.0 REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH SET NO. TESTED (days) {in.) (sq.in.) (lbs. force) (psi) F 5 1 4/25/97 7 6.00 28.27 115840 4100 C( 5 2 4/25/97 7 6.00 28.27 118480 4190 C( 5 3 5/16/97 28 6.00 28.27 137980 4880 ' C( 5 4 5/16/97 28 6.00 28.27 140520 4970 C( ADDITIONALCOMMENTS: Five (5) gallons of water added at site. Technician: Phillip L. Forrest Technician Report Of Tests Continued On Page 6 REPORT NO. 115568 PAGE 5 OF 8 SET NO. 5 8/97 BY: Phillip L. Forrest 0 CONCRETE: 74 TICKET NO: 344159 5 UNIT WEIGHT(pcf): N/A :ACTURE TYPE REMARKS ,NE ,NE ~NE ~NE Our lette~ and report~ are for the exclusive u~e of the client to whom they era ~¢ldressed and shall not be reprodu :ed except in i'uil without the approval of the i:esting laboratory The u~e of our name mL~t receiv~ our written approval.. Our la ctere end reports 1001 LW apply only to the sample tested and/or inspected, and are not indicative of the quantl~lee of apparent y identical or limilar products, Lincoln Property Co. PROJECT NO. 0903605034 OATE OFSERVICE: 4/18/97 REPORT OF CONCRETE COMPRESSIVE STRENGTH (Cont i hued) CONTRACTOR: BUTLER CONSTRUCTION CONCRETE SUPPLIER: PIONEER PLANT: 29 SPECIFICATION REQUIREMENTS STRENGTH: 4000psi @ 28 DAYS SLUMP: 5" METHOD OF TEST SAMPLING: ASTM C-172 MOLDING & CURING: ASTM C31 SLUMP: ASTM C143 TEMPERATURE: ASTM C-138 AIR CONTENT: N~A UNIT WEIGHT: N/A CAPPING/PADS: ASTM C617 TESTING: ASTM C39 CYLINDER MARKED DATE S ET N O. TESTED PROJECT DATA MIX DESIGN NUMBER: 9349 DATE OF PLACEMENT: 4/1 TIME SAMPLED: 11: 30AM TEMPERATURE (DegF) - AIR: 7 TRUCK NO: 731 MEASURED SLUMP (in.): 7.0 AIR CONTENT(%): N/A LOCATION OF PLACEMENT: F/7.8 REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS MAXIMUM COMPRESSIVE AGE DIAMETER AREA LOAD STRENGTH {days) (in.) (sq.in.) (lbs. force) (psi) FR 6 1 4/25/97 7 6.00 28.27 101230 3580 CO 6 2 4/25/97 7 6.00 28.27 105550 3730 CO 6 3 5/16/97 28 6.00 28.27 127020 4490 CO 6 4 5/16/97 28 6.00 28.27 137620 4870 CC ADOITIONALCOMMENTS: Note: Notified contractor of high slump on concrete. Technician: Phillip L. Forrest Technician Report Of Tests Continued On Page 7 REPORT NO. 115568 PAGE 6 OF 8 SET NO. 6 8/97 BY: Phillip L. Forrest CONCRETE: 78 TICKET NO: 344166 UNIT WEIGHT(pcf): N/A ACTURETYPE REMARKS NE NE NE NE Our letters and reporta are for the exclusive uae of the client to whom they are addreesed and shall not be reproduc. ,:1 except in full without the agprovai of the testing laboratory. The use of our name must receive our written approval. Ou~ let era and reports 1001 LW apply only to the sample tested and/or inspected, and are not indicative of the quantities of apparently identical or s, miler products. Lincoln Property Co. PROJECT NO. 0903605034 DATE OF SERVICE: 4/18/97 REPORT OF CONCRETE COMPRESSIVE STRENGTH (Continued) CONTRACTOR: BUTLER CONSTRUCTION CONCRETE SUPPLIER: PIONEER PLANT: 29 SPECIFICATION REQUIREMENTS STRENGTH: 40OOpsi @ 28 DAYS SLUMP: 5" METHOD OF TEST SAMPLING: ASTM C-172 MOLDING & CURING: ASTM C31 SLUMP: ASTM C143 TEMPERATURE: ASTM C-138 AIR CONTENT: N/A UNIT WEIGHT: N/A CAPPING/PADS: ASTM C617 TESTING: ASTM C39 CYLINDER MARKED DATE SET NO. TESTED PROJECT DATA MIX DESIGN NUMBER: 9349 DATE OF PLACEMENT: 4/1 TIME SAMPLED: 01: 12PM TEMPERATURE (DegF) - AIR: 8 TRUCK NO: 287 MEASURED SLUMP (in.): 6.0 AIR CONTENT(%): N/A LOCATION OF PLACEMENT: G/6.5 to 8.5 REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS MAXIMUM COMPRESSIVE AGE DIAMETER AREA LOAD STRENGTH (dayst {in.) (sq.in.I {lbs. force) (psi) FR 7 1 4/25/97 7 6.00 28.27 103270 3650 CO 7 2 4/25/97 7 6.00 28.27 99510 3520 CO 7 3 5/16/97 28 6.00 28.27 129880 4590 CO 7 4 5/16/97 28 6.00 28.27 116530 4120 CO ADDITIONALCOMMENTS: Note: Notified contractor of high slump on concrete. Technician: Phillip L. Forrest Technician Report Of Tests Continued On Page 8 REPORT NO. 115568 PAGE 7 OF 8 SET NO. 7 B/97 BY: Phillip L. Forrest CONCRETE: 82 TICKET NO: 366919 UNIT WEIGHT(pcf): N/A ,CTURE TYPE REMARKS ~E NE Our totters an4 rol;orts are for the exclusive u~e of the client to whom they sro ad, respa4 and shall not be repro(luc~ d except in full without the approval of the testing laboratory. The use of ou~ name must receive our written al~provel. Our let1 art and re~ort~ 1001 LW apply only to the sample tested and/or inspected, and are not indicative of the quantities of apparently identical or nilar p~'oducts. Lincoln Property Co. PROJECT NO. 0903605034 DATE OF SERVICE: 4/18/97 CONTRACTOR: BUTLER CONSTRUCTION CONCRETE SUPPLIER: PIONEER PLANT: 29 SPECIFICATION REQUIREMENTS STRENGTH: 4000psi @ 28 DAYS SLUMP: 5" METHOD OF TEST SAMPLING: ASTM C-172 MOLDING & CURING: ASTM C31 SLUMP: ASTM C143 TEMPERATURE: ASTM C-138 AIR CONTENT: N/A UNIT WEIGHT: N/A CAPPING/PADS: ASTM C617 TESTING: ASTM C39 REPORT OF CONCRETE COMPRESSIVE STRENGTH (Cont ~ nued) PROJECT DATA MIX DESIGN NUMBER: 9349 DATE OF PLACEMENT: 4/1 TIME SAMPLED: 02:05PM TEMPERATURE (DegF) - AIR: 8 TRUCK NO: 297 MEASURED SLUMP (in.): 4. AIR CONTENT(%): N/A LOCATION OF PLACEMENT: H/6.3 to 6.5 REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH SET NO. TESTED (days) (in.) {sq.in.) Ilbs. force) {psi) F 8 1 4/25/97 7 6.00 28.27 120570 4260 CC 8 2 4/25/97 7 6.00 28.27 124990 4420 CC 8 3 5/16/97 28 6.00 28.27 151320 5350 CC 8 4 5/16/97 28 6.00 28.27 147700 5220 CC REPORT NO. 115568 PAGE 8 OF 8 SET NO. 8 8/97 BY: Phillip L. Forrest CONCRETE: 80 TICKET NO: 366931 UNIT WEIGHT(pcf): N/A ACTURETYPE REMARKS NE NE NE NE Technician: Phillip L. Forrest Technician Report Distribution: ~~ (1) Lincoln Property Co. (1) BUTLER CONSTRUCTION INCORP. (I) BROCKETT-DAV1S-DRAKE, INC. (1) THE CITY OF COPPELL / (1) THE CITY OF COPPELL (1) O'8RIEN ASSOCIATES. INC. <~)A.E.C.C. / t~_ dken, B.S. ~~ P~oject Manager Our letters and reports ere for the exclusive uae of the client to whom they m'e addre~ed snd shall ~ be reprodu4ed except in Our le full without the approval of the testir~ laboratory. The u~e of out name mu~t receive our written approval. Keri and reportl of apparently identical or ! products. 1001 LW apply only to the sample tested end/or inspected, and are not indicative of the quantities ~imil~r :~N LABS Ch. E.