Loading...
Northlake 635(2)-LR 970502 (3)MA)aM TECHNOLOGIES INC ,^ Tech. a Southwestern Labs Lone Star Dr. a P.O. Box 224227 Dallas. Texas 75222 Telephone: (214) 831 -2700 FAX: (214) 920 -1891 REPORT OF DRILLED PIER INSPECTION CLIENT: Lincoln Property Co. 500 N. AKARD, SUITE 3300 ATTN: LARRY MOON Dallas, TX 75201 PROJECT COPPELL BUSINESS CENTER WRANGLER DR. & BELTLINE RD. COPPELL, TX SERVICES: Perform Drilled Pier Inspection. PROJECT NO.: 0903 505034 REPORT NO.: 1158i 1 DATE OF SERVICE: /25/97 AUTHORIZATION: Ongoing REPORT DATE: 5/q2/97 REPORT OF INSPECTION On this date, a Maxim Technologies representative arrived scheduled to perform a Drilled Pier Inspection. See atta results of the inspection. Technician Time: 8:00 am - 12:30 pm Page 1 of 2 Technician: Rusty Bowers Technician Report Distribution: I II III BU LLe CONSTRUCTION INCORP. MAXIM I 1 BROCKETT- DAVIS- DRAKE. INC. II THE CTY OF COPPELL I 11 THE C OF COPPELL II O'BRIEN ASSOCIATES. INC. 111 A E.C.C. L r G Our letters and reports we 1w the exclusive use of the client to whom they w addroeeed and shag net be i 1099 FR appl without onl oty tlr "mple ioie t wWw inspected. � we rot indicative t gwMitieeo ap w� iden site as report for �. Ae311, D.N. {""". P o je Manager we.nd t r v rf. w product. AAA)am TECHNOLOGIES INC 2575 Lone Star Drive a P.O. Box 224227 a Dallas. Texas 75222 (214) 631 -2700 a Fax (214) 920 -1891 LINCOLN PROPERTY COMPANY Project N Service Date:04 /25/97 DRILLED PIER INSPECTION (STRAIGHT SHAFM hate T)ri1h -d-4 /25/97 ** *0BSERVATION OF DR ELLED FOUNDATION Report N 115891 Page 2 of 2 UCTION * ** Pier identification A.2/8 A.2 /8.4 Pier diameter(in) 18 18 Depth of pier from surface(ft) 36.3 35.4 Depth of bearing stratum from surface(ft) 29.4 29.0 Required penetration(ft) 6.0 6.0 Actual penetration(ft) ` 8.9 6.4 Condition of bottom(wet /dry) DRY DRY Plumb within tolerance(yes /no) YES YES # of bars /Reinforcing bar size( #) 405 4/ #5 Length of reinforcing steel(ft) 34.6 33.4 Time drilling was completed(am /pm) 10:16a 10:36a Time concrete was placed(am /pm) 11:10a 11:30a Depth of pier from top of concrete(ft) 35.1 33.9 Elevation: Surf ace(ft)' • 99.2 99.5 Elevation:Top of pier (ft) ` ` 98.0 98.0 Elevation: Bottom pier (ft) • • 62.9 1 64.1 Elevation:Top of bearing stratum(ft) ' • 69.8 1 70.5 Bearing stratum (Description) Dark gray unweathered shale NOTE: SEE REPORT # 115892 FOR COMPRESSIVE STRENGTH TEST SPECIMENS. ' ADDITIONAL PENETRATION NOT REQUESTED UNLESS NOTED. ELEVATION BY OTHERS TIME: 8:00 A.M. TO 12:30 P.M. Our letters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduc except in full without the approval of the testing laboratory. The use of our name must receive prior written approval of Maxim Technologies, Inc. Letters and reports apply only to the sample tested and /or inspected and are not indicative of the quantity of apparently identical or similar pr ucts. MA)am TECHNOLOGIES INC Maxim Tech. • Southwestern Labs 2575 Lone Star Dr. 0 P.O. Box 224227 Dallas, Texas 75222 Telephone: (214) 631 -2700 FAX: (214) 920 -1891 REPORT OF CONCRETE INSPECTION CLIENT: Lincoln Property Co. 500 N. AKARD, SUITE 3300 ATTN: LARRY MOON Dallas, TX 75201 PROJECT: COPPELL BUSINESS CENTER WRANGLER DR. & BELTLINE RD. COPPELL, TX PAGE 1 OF 1 PROJECT NO.: 090360 034 REPORT NO.: 115798 DATE OF SERVICE: 4/24/97 AUTHORIZATION: Charlie REPORT DATE: 5/02/97 SERVICES: Observe concrete mixture for consistency at placement locat on, perform required field tests, and prepare compressive strength spec mens. PROJECT DATA CONTRACTOR: BUTLER CONSTRUCTION CLASS OF CONCRETE: 4000 SI @ 28 DAYS CONCRETE SUPPLIER: PIONEER DESIGN MIX NUMBER: 9363 PLANT: 74 REPORT OF INSPECTION BATCH PROPORTIONS Cement ASTM C -150 564 Ibs. Slump Range (in.) 5. 0 Air C ntent Range ( %): 4. 6 Coarse Aggr.: ASTM C -33 1840 Ibs. Range of Fresh Concrete Wt. /Cu. Ft.: /A Fine Aggr.: ASTM C -33 1268 Ibs. Air Temp. Range (DegF): 66 Conc. Temp. Range (DegF): 75 -78 Total Water: 252.0 lbs. Weather Conditions: cloudy /wind Water /Cement Ratio: 0.45 LB /LB Placement Location: Entrance between building B and C off Wrangler paving approach No. Cu. Yds. Placed: 88 No. Test Spec.: 4 Technician: Phillip L. Forrest Time - Started 03:30PM Stopped 07:OOPM SUMMARY OF INSPECTION: The technician observed the concrete mixture at placement location. The concrete was checked for proper mixing, and a visual estimate of slump was made. Also, the concrete was observed for workability, consistency, and uniformity. Samples of concrete were obtained for the required field tests and preparation of compressive strength specimens for laborat ry testing. Test results appear on Report of Concrete Compressive Strength. Technician: Phillip L. Forrest Technician Report Distribution: iii euTiER cONSTR INCORP. MAXIM TECH. SOUTHWES 11) BROCKETT - DAMS- DRAKE, INC. 11) THE CTY OF COPPELL (1) THE C OF COPPELL 11) 0 BRIEN ASSOCIATES, INC. 111 A.E.C.C. e cen, B.S. of ct Manager Our letters and reports are for the exclusive use of the client to whom they are dressed and shall not be reproduced ex e t in full without the approval of the testing laboratory. The use of our name must receive our written approval. Our letters a reports 1003 LW apply only to the sample tested and /or inspected, and are not indicative of the quantities of apparently identical or similar products. MA)C&M TECHNOLOGIES INC Maxim Tech. • Southwestern Labs 2575 Lone Star Dr. • P.O. Box 224227 Dallas, Texas 75222 Telephone: (214) 631 -2700 FAX: (214) 920 -1891 REPORT OF CONCRETE COMPRESSIVE STRENGTH CLIENT: Lincoln Property Co. 500 N. AKARD, SUITE 3300 ATTN: LARRY MOON Dallas, TX 75201 PROJECT: COPPELL BUSINESS CENTER WRANGLER DR. & BELTLINE RD. COPPELL, TX PAGE 1 OF 1 PROJECT NO.: 0903605034 REPORT NO.: 115798 DATE OF SERVICE: 4/241/97 AUTHORIZATION: Charlie REPORT DATE: 5/02/97 SERVICES: Test compressive strength specimens prepared in conjunction inspection. CONTRACTOR: BUTLER CONSTRUCTION CONCRETE SUPPLIER: PIONEER PLANT: 74 LOAD STRENGTH SPECIFICATION REQUIREMENTS (days STRENGTH: 4000psi @ 28 DAYS SLUMP: 4-5" (psi) FRACT AIR: 3 -6% METHOD OF TEST 6.00 28.27 SAMPLING: ASTM C -172 MOLDING & CURING: ASTM C31 SLUMP: ASTM C143 TEMPERATURE: ASTM C -138 AIR CONTENT: ASTM C231 UNIT WEIGHT: N/A CAPPING /PADS: ASTM C617 TESTING: ASTM C39 CYLINDER MARKED SET NO. 1 1 1 2 1 3 1 4 with concrete PROJECT DATA MIX DESIGN NUMBER: 9363 CLASS OF CONCRETE: 4000 PSI @ 28 DAYS DATE OF PLACEMENT: 4/24/97 TIME SAMPLED: 03:35PM Y: Phillip L. Forrest TEMPERATURE (DegF) - AIR: 66 CONCRETE: 78 TRUCK NO: 499 ICKET NO: 357095 MEASURED SLUMP fin.): 5.00 AIR CONTENT( %): 4.6 L NIT WEIGHT(pcf): LOCATION OF PLACEMENT: N/A 25 South of Wrangler, 5 east of west curb REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS MAXIMUM COMPRESSIVI DATE AGE DIAMETER AREA LOAD STRENGTH TESTED (days (in.) (sq.in.) (Ibs. force) (psi) FRACT 5/01/97 7 6.00 28.27 125360 4430 CONE 5/01/97 7 6.00 28.27 122490 4330 CONE 5/22/97 28 5/22/97 28 ADDITIONAL COMMENTS: Eight (8) gallons of water added at site. Technician: Phillip L. Forrest REMARKS Technician Report Distribution: I1) Su C NNS RUCTION INCORP. MAXIM TECH. • OUTHWES E (1) BROCKETT- DA1/IS•DRAKE, INC. (11 THE CITY OF COPPELL (11 THE CITY OF COPPELL (1) O'BRIEN ASSOCIATES, INC. (1) A.E.C.C. B acken, B.S. Ch.E. Proj ct Manager Our letters and reports are for the ex elusive use of the client to whom they are addressed and shall not be reproduced exc opt in full without the approval of the testing laboratory. The use of our name must receive our written approval. Our letters v d reports 1001 LW apply only to the sample tested and /or inspected, and are not indicative of the quantities of apparently identical or similar 3roducts.