Loading...
Northlake 635(4)-LR010518 GEOTECHNICALAND J ~ F~ J~] U F:a ENVIRONMENTAL CONSULTANTS I CONCRETE CYLINDER TEST REPORT Coppell Tech Center II 1322 Crestside Coppell, Texas REPORTED TO: Bob Moore Construction Co. 1110 N. Watson Road Arlington, Texas 76011 ATTN: Mr. Ed T. McGuire REPORT NO. 111 REG PROJECT NO. 7044 SAMPLE DATE: 05-18-01 TECHNICIAN: D. French J Quantity Represented CONTRACTOR: Bob Moore Construction Co. Location of Sample r S et Number J Location 1 Sidewalk: 2'S, 390'E of S.W. building corner 10/70 Design Information J Source of Concrete J Mix Identification J Specified Strength p.s.i. TXI 8204 3000 Test Results Set Cylinderr No. ID Date Tested 1 7862 05-25-01 7862 06-15-01 7862 06-15-01 7862 Hold Age@ TotalLoad J Compressive J Average Test lbs. Strength p.s.i. Strength p.s.i. 7 28 28 H 98420 3480 Cylinder Data Set Cylinder J Time of No. ID J Slump Sample I 7862 4.50 11:00AM J Concrete J Air Ticket Air Temp. Temp. Entrainment Number 79 92 N/A 2893519 Mail Distribution: (1) Bob Moore Construction Co./ Mr. Ed T. McGuire (1) City of Coppell/Mr. Larry Davis (1) City of Coppell/Mr. Lee Stone (1) McHale Consulting Engineering/ Mr. Gary McHale (1) CMC-Commercial Realty/ Mr. Steve Huff (1) AECC, Inc./Mr. Chad Stevens Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Keith Atkins KEA/je 2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019