Northlake 635(4)-LR010405 (2) GEOTECHNICALAND J ~ F~l I-~ I I F~
ENVIRONt4ENTAL CONSULTANTS
I
CONCRETE CYLINDER TEST REPORT
Coppell Tech Center II
1322 Crestside
Coppell, Texas
REPORTED TO:
Bob Moore Construction Co.
1110 N. Watson Road
Arlington, Texas 76011
A'I'TN: Mr. Ed T. McGuire
CONTRACTOR: Bob Moore Construction Co.
Location of Sample
Set Number I Location
REPORT NO. 102
REG PROJECT NO. 7044
SAMPLE DATE: 04-05-01
TECHNICIAN: H. Johnson
Quantity Represented
1 Sidewalk: 10'S, 330'E of S.W. corner of west wing 10/30
of building
Design Information
I Source of Concrete I Mix Identification I Specified Strength p.s.i.
TXI 8204 3000
Test Results
No.Set CylinderlID
1 5462
5462
5462
Age@ Total Load I CompressiveI Average
Date Tested Test lbs. Strength p.s.i. Strength p.s.i.
04-12-01 7 84580 2990
05-03-01 28 110890 3920
05-03-01 28 116820 4130
4O3O
Cylinder Data
SetI Cylinder I
l N~. ID Slump
5462 5.00
Time of Concrete
Sample Air Temp. Temp.
12:40PM 70 74
Air I Ticket
Entrainment Number
3.8 2856196
Mail
Distribution:
(1) Bob Moore Construction Co./
Mr. Ed T. McGuire
(1) City of Coppell/Mr. Larry Davis
(1) City of Coppell/Mr. Lee Stone
(1) McHale Consulting Engineering/
Mr. Gary McHale
(1) CMC-Commercial Realty/
Mr. Steve Huff
(1) AECC, Inc./Mr. Chad Stevens
Submitted by:
REED ENGINEERING GROUP, INC.
Original Signed By
Keith Atkins
KEA/je
2424 STUTZ DR. · SUITE 400 * DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019