Loading...
Northlake 635(4)-LR010328 (3) I GEOTECHNICALAND I ~ F:~ I'-1 I I p ENVIRONMENTAL CONSULTANTS REPORT OF SIEVE ANALYSIS Coppell Tech Center II 1322 Crestside Coppell, Texas REPORTED TO: CONTRACTOR: Bob Moore Construction Co. 1110 N. Watson Road Arlington, Texas 76011 ATTN: Mr. Ed T. McGuire Bob Moore Construction Co. REPORT NO. 88 REPORT DATE: 03-28-01 REG PROJECT NO. 7044 DATE SAMPLED: 03-16-01 TECHNICIAN: B. Pitts PAGE: 1 of 1 Material Description: Gravel Proposed Usage: Roof Ballast Reference Standard: ASTM D-1863-86 Size 67A U.S. Std. J Cumulative Sieve Size I Percent Passing Specification Percent Finer 1' 100 100 3/4" 100 90 - 100 3/8" 31 20-55 No. 4 1.0 0-10 No. 8 0.2 0 - 5 The sample conforms to the referenced specifications. Mail Distribution: (1) Bob Moore Construction Co./ Mr. Ed T. McGuire (1) City of Coppell/Mr. Larry Davis (1) City of Coppell/Mr. Lee Stone (1) McHale Consulting Engineering/ Mr. Gary McHale (1) CMC-Commercial Realty/ Mr. Steve Huff (1) AECC, Inc./Mr. Chad Stevens Submitted by: REED ENGINEERING GROUP, INC. Original Signed By James F. Phipps, P.E. AE/mm 2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019