Loading...
Northlake 635(4)-LR010320 GEOTECHNICAL AND ENVIRONPIENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Coppell Tech Center II 1322 Crestside Coppell, Texas REPORTED TO: Bob Moore Construction Co. 1110 N. Watson Road Arlington, Texas 76011 ATTN: Mr. Ed T. McGuire REPORT NO. 95 REG PROJECT NO. 7044 SAMPLE DATE: 03-20-01 TECHNICIAN: F. Steadman CONTRACTOR: Bob Moore Construction Co. Location of Sample l S et Number I Location 1 Slab leaveout: A-1 to B-1 and A-1 to A-4 20/70 Design Information l Source of Concrete I Mix Identification I Specified Strength p.s.i. TXI 45 3000 Quantity Represented Test Results Set Cylinder Age @ No. ID Date Tested Test Total Load I CompressiveI Average lbs. Strength p.s.i. Strength p.s.i. 1 4814 03-27-01 7 80480 2850 4814 04-17-01 28 4814 04-17-01 28 4814 Hold H Cylinder Data Set Cylinder I TimeofI I Concrete Air TicketI N1o. ID Slump Sample Air Temp. Temp. Entrainment Number 4814 5.00 8:45AM 39 58 N/A 2844110 Mail Distribution: (1) Bob Moore Construction Co./ Mr. Ed T. McGuire (1) City of Coppell/Mr. Larry Davis (1) City of Coppell/Mr. Lee Stone (1) McHale Consulting Engineering/ Mr. Gary McHale (1) CMC-Commercial Realty/ Mr. Steve Huff (1) AECC, Inc./Mr. Chad Stevens Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Keith Atkins KEA/je 2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 ,, TEL [214] 350 5600" FAX [214] 350 0019