Loading...
Northlake 635(4)-LR010221GEOTECHNICAL AND G F=~ r-'l I I F~ ENVIRONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Coppell Tech Center II 1322 Crestside Coppell, Texas REPORTED TO: Bob Moore Construction Co. 1110 N. Watson Road Arlington, Texas 76011 ATTN: Mr. Ed T. McGuire REPORT NO. 85 REG PROJECT NO. 7044 SAMPLE DATE: 02-21-01 TECHNICIAN: E. Beacham CONTRACTOR: Bob Moore Construction Co. Location of Sample Set Number I Location Quantity Represented 1 2 3 4 5 Paving: 38'S, 50'E of S.W. corner of building Paving: 72'S,93'E of S.W. corner of building Paving: 150'S,93'E of S.W. corner of building Paving: 5'S,230'E of S.W. corner of building Paving: 5'S,336'E of S.W. corner of building 110/570 210/570 3OO/57O 420/570 530/570 Design Information Source of Concrete TXI Mix Identification 8273 Specified Strength p.s.i. 4000 Test Results Set CylinderI No. ID Date Tested 1 4003 02-28-01 4003 03-21-01 4003 03-21-01 4003 Hold Age @ Test Total Load lbs. 7 96340 28 28 H 2 4004 02-28-01 7 4004 03-21-01 28 4004 03-21-01 28 4004 Hold H 3 4005 02-28-01 7 4005 03-21-01 28 4005 03-21-01 28 4005 Hold H 4 4006 02-28-01 7 4006 03-21-01 28 4006 03-21-01 28 4006 Hold H I Compressive I Average Strength p.s.i. Strength p.s.i. 3410 93730 3320 1O479O 3710 98310 3480 2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019 Test Results Set Cylinder No. ID Date Tested Age @ Test Total Load J Compressive lbs.I Strength p.s.i. Average Strength p.s.i. 5 4007 02-28-01 4007 03-21-01 4007 03-21-01 4007 Hold 7 28 28 H 98060 3470 Cylinder Data Set Cylinder No. ID 1 4003 2 4004 3 4005 4 4006 5 4007 Slump Sample Air Temp. Temp. Entrainment Number 6.00 6:20 AM 67 75 4.1 2829005 6.00 7:40 AM 63 72 4.4 2829088 6.00 8:45 AM 62 69 4.4 2829198 6.00 9:30 AM 63 73 4.1 2829369 6.00 12:00 PM 61 74 4.3 2829522 Mail Distribution: (1 (1 ) Bob Moore Construction Co./ Mr. Ed T. McGuire ) City of Coppell/Mr. Larry Davis ) City of Coppell/Mr. Lee Stone ) McHale Consulting Engineering/ Mr. Gary McHale ) CMC-Commercial Realty/ Mr. Steve Huff ) AECC, Inc./Mr. Chad Stevens Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Keith Atkins KEA/mm