Northlake 635(4)-LR010131GEOTECHNICAL AND [:~ F:=J I'-1
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
Coppell Tech Center II
1322 Crestside
Coppell, Texas
REPORTED TO:
Bob Moore Construction Co.
1110 N. Watson Road
Arlington, Texas 76011
ATTN: Mr. Ed T. McGuire
CONTRACTOR: Bob Moore Construction Co.
REPORT NO. 81
REG PROJECT NO. 7044
SAMPLE DATE: 01-31-01
TECHNICIAN: R. Estep
Location of Sample
ISet Number I Location I Quantity Represented
1 Screenwall piers: 101A, 101 and 102 10/16
Design Information
l Source of Concrete I Mix Identification I Specified Strength p.s.i.
TXI 9505 3000
Test Results
Set Cylinder I
No. ID Date Tested
1 3329 02-07-01
3329 02-07-01
3329 02-28-01
3329 02-28-01
Age@ Total Load I CompressiveI Average
Test lbs. Strength p.s.i. Strength p.s.i.
7 6687O 2370
7 71930 2550 2460
28 135820 4810
28 133080 4710 4760
Cylinder Data
Set Cylinder [ I Timeof
No. ID Slump Sample
I
3329 5.50
J Concrete Air J Ticket
Air Temp. Temp. Entrainment Number
12:05PM 48
55 N/A 2817649
Mail
Distribution:
(1) Bob Moore Construction Co./
Mr. Ed T. McGuire
(1) City of Coppell/Mr. Larry Davis
(1) City of Coppeil/Mr. Lee Stone
(1) McHale Consulting Engineering/
Mr. Gary McHale
(1) CMC-Commercial Realty/
Mr. Steve Huff
(1) AECC, Inc./Mr. Chad Stevens
Submitted by:
REED ENGINEERING GROUP, INC.
Original Signed By
Keith Atkins
KENje
2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019