Northlake 635(4)-LR010131GEOTECHNICAL AND [:~ F:=J I'-1 ENVIRONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Coppell Tech Center II 1322 Crestside Coppell, Texas REPORTED TO: Bob Moore Construction Co. 1110 N. Watson Road Arlington, Texas 76011 ATTN: Mr. Ed T. McGuire CONTRACTOR: Bob Moore Construction Co. REPORT NO. 81 REG PROJECT NO. 7044 SAMPLE DATE: 01-31-01 TECHNICIAN: R. Estep Location of Sample ISet Number I Location I Quantity Represented 1 Screenwall piers: 101A, 101 and 102 10/16 Design Information l Source of Concrete I Mix Identification I Specified Strength p.s.i. TXI 9505 3000 Test Results Set Cylinder I No. ID Date Tested 1 3329 02-07-01 3329 02-07-01 3329 02-28-01 3329 02-28-01 Age@ Total Load I CompressiveI Average Test lbs. Strength p.s.i. Strength p.s.i. 7 6687O 2370 7 71930 2550 2460 28 135820 4810 28 133080 4710 4760 Cylinder Data Set Cylinder [ I Timeof No. ID Slump Sample I 3329 5.50 J Concrete Air J Ticket Air Temp. Temp. Entrainment Number 12:05PM 48 55 N/A 2817649 Mail Distribution: (1) Bob Moore Construction Co./ Mr. Ed T. McGuire (1) City of Coppell/Mr. Larry Davis (1) City of Coppeil/Mr. Lee Stone (1) McHale Consulting Engineering/ Mr. Gary McHale (1) CMC-Commercial Realty/ Mr. Steve Huff (1) AECC, Inc./Mr. Chad Stevens Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Keith Atkins KENje 2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019