Loading...
Northlake 635(4)-LR010126GEOTECHNICALAND J I~ F=l I'-! I I ENVIRONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Coppell Tech Center II 1322 Crestside Coppell, Texas REPORTED TO: Bob Moore Construction Co. 1110 N. Watson Road Arlington, Texas 76011 A'I'TN: Mr. Ed T. McGuire CONTRACTOR: Bob Moore Construction Co. Location of Sample Set Number J Location REPORT NO. 80 REG PROJECT NO. 7044 SAMPLE DATE: 01-26-01 TECHNICIAN: R. Estep Quantity Represented 1 Screenwall Piers: 116, 117, 118 and 120 10/15 Design Information l Source of Concrete I Mix Identification I Specified Strength p.s.i. TXI 9505 3000 Test Results Set CylinderI No. ID Date Tested 1 3208 02-02-01 3208 02-02-01 3208 02-23-01 3208 02-23-01 Age@ Total Load I CompressiveI Average Test lbs. Strength p.s.i. Strength p.s.i. 7 82220 2910 7 82460 2920 2920 28 128770 4560 28 129870 4600 4580 Cylinder Data SetI Cylinder I l NlO. ID Slump 3208 4.75 Time of Sample I ConcreteI Air Ticket Air Temp. Temp. Entrainment Number 1:55PM 56 63 N/A 2815816 Mail Distribution: (1) Bob Moore Construction Co./ Mr. Ed T. McGuire (1) City of Coppell/Mr. Larry Davis (1) City of Coppell/Mr. Lee Stone (1) McHale Consulting Engineering/ Mr. Gary McHale (1) CMC-Commercial Realty/ Mr. Steve Huff (1) AECC, Inc./Mr. Chad Stevens Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Keith Atkins KENje 2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019