Northlake 635(4)-LR010126GEOTECHNICALAND J I~ F=l I'-! I I
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
Coppell Tech Center II
1322 Crestside
Coppell, Texas
REPORTED TO:
Bob Moore Construction Co.
1110 N. Watson Road
Arlington, Texas 76011
A'I'TN: Mr. Ed T. McGuire
CONTRACTOR: Bob Moore Construction Co.
Location of Sample
Set Number J Location
REPORT NO. 80
REG PROJECT NO. 7044
SAMPLE DATE: 01-26-01
TECHNICIAN: R. Estep
Quantity Represented
1 Screenwall Piers: 116, 117, 118 and 120 10/15
Design Information
l Source of Concrete I Mix Identification I Specified Strength p.s.i.
TXI 9505 3000
Test Results
Set CylinderI
No. ID Date Tested
1 3208 02-02-01
3208 02-02-01
3208 02-23-01
3208 02-23-01
Age@ Total Load I CompressiveI Average
Test lbs. Strength p.s.i. Strength p.s.i.
7 82220 2910
7 82460 2920 2920
28 128770 4560
28 129870 4600 4580
Cylinder Data
SetI Cylinder I
l NlO. ID Slump
3208 4.75
Time of
Sample
I ConcreteI Air Ticket
Air Temp. Temp. Entrainment Number
1:55PM
56 63 N/A 2815816
Mail
Distribution:
(1) Bob Moore Construction Co./
Mr. Ed T. McGuire
(1) City of Coppell/Mr. Larry Davis
(1) City of Coppell/Mr. Lee Stone
(1) McHale Consulting Engineering/
Mr. Gary McHale
(1) CMC-Commercial Realty/
Mr. Steve Huff
(1) AECC, Inc./Mr. Chad Stevens
Submitted by:
REED ENGINEERING GROUP, INC.
Original Signed By
Keith Atkins
KENje
2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019