Northlake 635(4)-LR001211 (3) GEOTECHNICAL AND J ~ Jc~J I"'1 U F~ ENVlRONHENTAL CONSULTANTS I CONCRETE CYLINDER TEST REPORT Coppell Tech Center II 1322 Crestside Coppell, Texas REPORTED TO: Bob Moore Construction Co. 1110 N. Watson Road Arlington, Texas 76011 ATTN: Mr. Ed T. McGuire CONTRACTOR: Bob Moore Construction Co. REPORT NO. 61 REG PROJECT NO. 7044 SAMPLE DATE: 12-11-00 TECHNICIAN: J. Stuart Location of Sample Set Number I Location I Quantity Represented 1 Pier # D.1-0.8 18/18 Design Information Is°urce °f c°ncrete ITXl Mix Identification 9505 J Specified Strength P's'i' Test Results Set CylinderI No. ID Date Tested 1 2193 12-18-00 2193 12-18-00 2193 01-08-01 2193 01-08-01 J Age @ J Total Load I Compressive Average Test lbs. Strength p.s.i. Strength p.s.i. 7 69390 2460 7 64050 2270 2370 28 135040 4780 28 125720 4450 4620 Cylinder Data Set Cylinder I Time of No. ID SlumpI Sample I 2193 5.00 11:00AM I Concrete Air Ticket Air Temp. Temp. Entrainment Number 35 51 N/A 2794291 Mail Distribution: (1) Bob Moore Construction Co./ Mr. Ed T. McGuire (1) City of Coppell/Mr. Larry Davis (1) City of Coppell/Mr. Lee Stone (1) McHale Consulting Engineering/ Mr. Gary McHale (1) CMC-Commercial Realty/ Mr. Steve Huff (1) AECC, Inc./Mr. Chad Stevens Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Keith Atkins KEA/je 2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019