Northlake 635(4)-LR001208 GEOTECHNICAL AND J J:~ F=;J I'-'1 L.J F~
ENVIRONHENTAL CONSULTANTS
I
CONCRETE CYLINDER TEST REPORT
Coppell Tech Center II
1322 Crestside
Coppell, Texas
REPORTED TO:
Bob Moore Construction Co.
1110 N. Watson Road
Arlington, Texas 76011
ATTN: Mr. Ed T. McGuire
CONTRACTOR: Bob Moore Construction Co.
Location of Sample
Set Number J Location
Piers: D.4-4.4, C.3-1, B.7-1 and B.2-1
REPORT NO. 60
REG PROJECT NO. 7044
SAMPLE DATE: 12-08-00
TECHNICIAN: D. Williams
J Quantity Represented
10/24
Design Information
Source of Concrete
Mix Identification
Specified Strength p.s.i.
TXI 9505 3000
Test Results
SetNo. CylinderlID
1 2104
2104
2104
2104
Age @
Date Tested Test
12-15-00 7
01-05-01 28
01-05-01 28
Hold H
Total Load J Compressive J Average
lbs. Strength p.s.i. Strength p.s.i.
73890 2610
119400 4230
129010 4570
44OO
Cylinder Data
Set Cylinder
J Concrete Air Ticket
Air Temp. Temp. Entrainment Number
J Time of
ID Slump Sample
2104 5.00 3:00PM
60 65 N/A 2793738
Mail
Distribution:
(1) Bob Moore Construction Co./
Mr. Ed T. McGuire
(1) City of Coppell/Mr. Larry Davis
(1) City of Coppell/Mr. Lee Stone
(1) McHale Consulting Engineering/
Mr. Gary McHale
(1) CMC-Commercial Realty/
Mr. Steve Huff
(1) AECC, Inc./Mr. Chad Stevens
Submitted by:
REED ENGINEERING GROUP, INC.
Original Signed By
Keith Atkins
KEA/je
2424 STUTZ DR. · SUITE 400 * DALLAS, TX 75235 · TEL [214] 350 5600 * FAX [214] 350 0019