Loading...
Northlake 635(4)-LR001207G£OTECNNICALAND ~ F~ r~l I I p ENVIRONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Coppell Tech Center II 1322 Crestside Coppell, Texas REPORTED TO: Bob Moore Construction Co. 1110 N. Watson Road Arlington, Texas 76011 ATTN: Mr. Ed T. McGuire REPORT NO. 57 RE(:; PROJECT NO. 7044 SAMPLE DATE: 12-07-00 TECHNICIAN: D. Williams CONTRACTOR: Bob Moore Construction Co. Location of Sample ISet Number I Location 1 Piers: D.1-18.7, D.1-4.7, D-4.2 and D-3.7 10/30 Design Information I Source of Concrete I Mix Identification I Specified Strength p.s.i. TXI 9505 3000 I Quantity Represented Test Results Set CylinderI No. ID Date Tested 1 2030 12-14-00 2030 01-04-01 2030 01-04-01 2030 Hold Age@ Total Load I CompressiveI Average Test lbs. I IStrength p.s.i. Strength p.s.i. 7 77480 2740 28 122610 4340 28 124250 4400 H 4370 Cylinder Data Set ID Slump Sample Air Temp. Temp. 2030 4.50 2:05PM 63 62 Air Ticket Entrainment Number N/A 2792288 Mail Distribution: (1) Bob Moore Construction Co./ Mr. Ed T. McGuire (1) City of Coppell/Mr. Larry Davis (1) City of Coppell/Mr. Lee Stone (1) McHale Consulting Engineering/ Mr. Gary McHale (1) CMC-Commercial Realty/ Mr. Steve Huff (1) AECC, Inc./Mr. Chad Stevens Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Keith Atkins KEA/je 2424 STUTZ DR. * SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019