Loading...
Northlake 635(4)-LR001130GEOTECHNICALAND ~ F=;I r'l I I F=~ ENVIRONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Coppell Tech Center II 1322 Crestside Coppell, Texas REPORTED TO: Bob Moore Construction Co. 1110 N. Watson Road Arlington, Texas 76011 ATTN: Mr. Ed T. McGuire REPORT NO. 48 REG PROJECT NO. 7044 SAMPLE DATE: 11-30-00 TECHNICIAN: J. Stuart Quantity Represented CONTRACTOR: Bob Moore Construction Co. Location of Sample Set Number I Location 1 Piers: A-10.5, A-10 and A-9.5 10/30 Design Information l Source of Concrete I Mix Identification I Specified Strength p.s.i. TXI 9505 3000 Test Results Set CylinderI No. ID Date Tested 1 1731 12-07-00 1731 12-07-00 1731 12-28-00 1731 12-28-00 Age @ Total Load I Compressive Average Test lbs.I Strength p.s.i. Strength p.s.i. 7 92020 7 94310 28 132000 28 133590 326O 3340 3300 4670 4730 4700 Concrete Air Ticket Entrainment Number Cylinder Data Set Cylinder I Timeof I N1o. ID Slump Sample Air Temp. Temp. 1731 4.50 12:15PM 64 68 N/A 2785865 Mail Distribution: (1) Bob Moore Construction Co./ Mr. Ed T. McGuire (1) City of Coppell/Mr. Larry Davis (1) City of Coppell/Mr. Lee Stone (1) McHale Consulting Engineering/ Mr. Gary McHale (1) CMC-Commercial Realty/ Mr. Steve Huff (1) AECC, Inc./Mr. Chad Stevens Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Keith Atkins KEA/je 2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019