Northlake 635(4)-LR001130GEOTECHNICALAND ~ F=;I r'l I I F=~
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
Coppell Tech Center II
1322 Crestside
Coppell, Texas
REPORTED TO:
Bob Moore Construction Co.
1110 N. Watson Road
Arlington, Texas 76011
ATTN: Mr. Ed T. McGuire
REPORT NO. 48
REG PROJECT NO. 7044
SAMPLE DATE: 11-30-00
TECHNICIAN: J. Stuart
Quantity Represented
CONTRACTOR: Bob Moore Construction Co.
Location of Sample
Set Number I Location
1 Piers: A-10.5, A-10 and A-9.5 10/30
Design Information
l Source of Concrete I Mix Identification I Specified Strength p.s.i.
TXI 9505 3000
Test Results
Set CylinderI
No. ID Date Tested
1 1731 12-07-00
1731 12-07-00
1731 12-28-00
1731 12-28-00
Age @ Total Load I Compressive Average
Test lbs.I Strength p.s.i. Strength p.s.i.
7 92020
7 94310
28 132000
28 133590
326O
3340 3300
4670
4730 4700
Concrete Air Ticket
Entrainment Number
Cylinder Data
Set Cylinder I Timeof I
N1o. ID Slump Sample Air Temp. Temp.
1731 4.50 12:15PM 64
68 N/A 2785865
Mail
Distribution: (1)
Bob Moore Construction Co./
Mr. Ed T. McGuire
(1) City of Coppell/Mr. Larry Davis
(1) City of Coppell/Mr. Lee Stone
(1) McHale Consulting Engineering/
Mr. Gary McHale
(1) CMC-Commercial Realty/
Mr. Steve Huff
(1) AECC, Inc./Mr. Chad Stevens
Submitted by:
REED ENGINEERING GROUP, INC.
Original Signed By
Keith Atkins
KEA/je