Northlake 635(4)-LR001129 GEOTECHNICAL AND ENVIRONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Coppell Tech Center II 1322 Crestside Coppell, Texas REPORTED TO: Bob Moore Construction Co. 1110 N. Watson Road Arlington, Texas 76011 ATTN: Mr. Ed T. McGuire CONTRACTOR: Bob Moore Construction Co. Location of Sample Set Number I Location 1 Piers: C-12, C-13, C-14 REPORT NO. 47 REG PROJECT NO. 7044 SAMPLE DATE: 11-29-00 TECHNICIAN: J. Stuart Quantity Represented 10/10 Design Information Source of Concrete TXI Mix Identification Specified Strength p.s.i. 9505 3000 Test Results SetNo. CylinderlID Age @ Date Tested Test 1687 1687 1687 1687 ITotal Load Compressive I Average lbs. Strength p.s.i. Strength p.s.i. 12-06-00 7 105430 3730 12-06-00 7 113560 4020 3880 12-27-00 28 146330 5180 12-27-00 28 144580 5120 5150 Cylinder Data SetI Cylinder 1687 Slump Sample Air Temp. Temp. Entrainment Number 4.75 9:45AM 54 63 N/A N/A Mail Distribution: (1) Bob Moore Construction Co./ Mr. Ed T. McGuire (1) City of Coppell/Mr. Larry Davis (1) City of Coppell/Mr. Lee Stone (1) McHale Consulting Engineering/ Mr. Gary McHale (1) CMC-Commercial Realty/ Mr. Steve Huff (1) AECC, Inc./Mr. Chad Stevens Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Keith Atkins KENcg 2424 STUTZ DR. * SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019