Northlake 635(2)-LR 970305Maxi~
25]
TECHNOLOGIES INC
CLIENT:
PROJECT:
SERVICES:
REPORT OF
CONCRETE COMPRESSIVE STRENGTH
Lincoln Property Co.
500 N. AKARD, SUITE 3300
ATTN: LARRY MOON
Dallas, TX 75201 PROJECT NO.: 0903(
REPORT NO.: 11224
COPPELL BUSINESS CENTER DATE OF SERVICE: 2
WRANGLER DR. & BELTLINE RD. AUTHORIZATION:
COPPELL, TX REPORT OATE: 3/0
Test compressive strength specimens prepared in conjuncti
inspection.
PROJECT DATA
CONTRACTOR: RUTLER CONSTRUCTTON MIX DESIGN NUMBER: 9339
CONCRETE SUPPLIER: PIONEER DATE OF PLACEMENT: 2/0
PLANT: 22 TIME SAMPLED: 04: 30AM
SPECIFICATION REQUIREMENTS TEMPERATURE (°F) - AIR: 37
STRENGTH: 3000psi @ 28 DAYS TRUCK NO: 136
SLUMP: 5" AIR CONTENT(%): 5.5
AIR: 3-6% LOCATION OF PLACEMENT:
METHOD OFTEST: ASTM C-39 40' South X 30' West
of building "C" park
REPORT OF TESTS
CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS
CYLINDER MEASURED MAXIMUM
MARKED SLUMP DATE AGE DIAMETER AREA LOAD
SET NO. (inches) TESTED (days) (in.) (sq.in.~ (lbs. force)
i i 5.00 2/12/97 7 6.00 28.27 107020
I 2 5.00 3/05/97 28 6.00 28.27 129440
i 3 5.00 3/05/97 28 6.00 28.27 128170
I 4 HOLD HOLD
CI
Technician: Abdullah Ethem
Technician
Report Of Tests Continued On Page 2
1001 LW
n Tach. · Southwestern Labs
5 Lone Star Dr. · P.O. Box 224227
Dallas, Texae 75222
Telephone: (214) 631-2700
FAX: (214) 920-1891
~05034
IO5/97
5/97
3n with concrete
5/97
BY: Abdullah Ethem
CONCRETE: 44
TICKET NO: 340749
from northwest corner
Lng lot
)MPRESSIVE
~TRENGTH
(osi)
3780
4580
4530
REMARKS
Ou~ Iottem and rel;~rtl ere f~ the a~clu.ive ule cf ~ ~ to w~m t~y ~e ~dr~ ~ ~MI ~ ~ re~ ] ex~ in
f~l wit~ ~ ~provM of t~ t~tl~ IlboritoW, T~ a of ~nlme m~t receive o~ wr~ ipprovm, u~ le~ ~ ~ r~
Lincoln Property Co.
PROJECT NO. 0903605034
DATE OF SERVICE: 2/05/97
REPORT OF
CONCRETE COMPRESSIVE STRENGTH
(Continued)
CONTRACTOR: BUTLER CONSTRUCTION
CONCRETE SUPPLIER: PIONEER
PLANT: 22
SPECIFICATION REQUIREMENTS
STRENGTH: 3000psi @ 28 DAYS
SLUMP: 5"
AIR: 3-6%
METHOD OF TEST: ASTM C-39
PROJECT DATA
MIX DESIGN NUMBER: 9339
DATE OF PLACEMENT: 2/0
TIME SAMPLED: 08:00AM
TEMPERATURE ( I F) - AIR: 41
TRUCK NO: 296
AIR CONTENT(%): 5.0
LOCATION OF PLACEMENT:
45' North X 25' east
corner of building"
CYLINDER MEASURED
MARKED SLUMP DATE
SET NO. (inches) TESTED
2 1 5.00 2/12/97
2 2 5.00 3/05/97
2 3 5.00 3/05/97
2 4 HOLD
REPORT OF TESTS
CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS
MAXIMUM
AGE DIAMETER AREA LOAD
(days) (in.) (sq.in.) (lbs. force)
7 6.00 28.27 198820
28 6.00 28.27 129440
28 6.00 28.27 130360
HOLD
ADDITIONALCOMMENTS:
Ten (10) gallons of water added
Technician: Abdullah Ethem
Technician
Report Distribution: MAXIM TEC~
(1) Lincoln Proper~y Co. (1) A.E.C.C.
(~ .UT,E. CO. ST.UCT,O. ~.C0...
(1) BR0CEETT-0AVIS-DRAKE, [NC. ~
(1) THE CITY OF COPPELL ' '- -
T.E C,TY OF C0.PELL /
¢~) 0',,,E. ,SS0C~**ES. mc. / / --
1001 LW Our ]ettem and rel=or~ we fa the e.xctusive use of the client to whom the~F'-er~-"a~'~rd eased and. ~h~l ~. re~r~l. _u~
fu# without the approval of the teStl~ laboratory. The use of ourna~e must receive our Wrlttefl
~ply ~y to t~ s~ple t~ ~ i~ct~, ~ me ~{ i~icl~ve of t~ qu~titi~ of
REPORT NO.
PAGE 2
SET NO. 2
112241
5/97
BY: Abdullah Ethem
CONCRETE: 48
TICKET NO: 340773
from southeast
B" parking lot
~)MPRESSIVE
~TRENGTH
(psi)
3850
4580
4610
REMARKS
LABS
~ ~c~ ~n, B.S. Ch.E.
anager
d except in
r~ and rep~
nil,.' I~cduc~.