REPORT OF
CONCRETE COMPRESSIVE STRENGTH
Lincoln Property Co.
500 N. AKARD, SUITE 3300
ATTN: LARRY MOON
Dallas, TX 75201
COPPELL BUSINESS CENTER
WRANGLER DR. & BELTLINE RD.
COPPELL, TX
SERVICES: Test compressive strength specimens
inspection.
PROJECT NO.: 0903~
REPORT NO.: 11224
DATE OF SERVICE: 2
AUTHORIZATION:
REPORT DATE: 2/1
prepared in conjuncti
CONTRACTOR: BUTLER CONSTRUCTION
CONCRETE SUPPLIER: PIONEER
PLANT: 22
SPECIFICATION REQUIREMENTS
STRENGTH: 3000psi @ 28 DAYS
SLUMP: 5"
AIR: 3-6%
METHOD OF TEST: ASTH C-39
PROJECT DATA
MIX DESIGN NUMBER: 9339
DATE OF PLACEMENT: 2/0
TIME SAMPLED: 04: 30AM
TEMPERATURE (°F) - AIR: 37
TRUCK NO: 136
AIR CONTENT(%): 5.5
LOCATION OF PLACEMENT:
40' South X 30' West
of building "C" park
CYLINDER MEASURED
MARKED SLUMP
SET NO. {inches)
1 1 5.00
1 2
1 3
1 4
REPORT OF TESTS
CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS
MAXIMUM
DATE AGE
TESTED {days)
2/12/97 7
3/05/97 28
3/05/97 28
DIAMETER AREA LOAD
{in.) (sq.in.) (lbs. force)
6.00 28.27 107020
HOLD HOLD
Technician: Abdullah Ethem
Technician
Report Of Tests Continued On Page 2
1001 LW
Tech. ·Southwestem Labs
Lone Star Dr. · P.O. Box 224227
Dallas, Texas 75222
Telephone: (214) 631-2700
FAX: {214) 920-1891
i05034
1
/05/97
4/97
on with concrete
/97
BY: Abdullah Ethem
CONCRETE: 44
TICKET NO: 340749
from northwest corner
ng lot
DMPRESSIVE
STRENGTH
Ipsi)
3780
REMARKS
Our letters end reports are for the exclusive u~e of the client to whom they are addressed er~cl shell not be repreduc~ d except in
full without the approval of the testing leboretol7. The ule of ourname must receive ou~ written approval. Our left; ri ~ reports
apply only to the sample tested and/or inspected, and are not indicative of the quantities of apparently identical or nilar ~3roducts.
Lincoln Property Co.
PROJECT NO. 0903605034
DATE OF SERVICE: 2/05/97
REPORT OF
CONCRETE COMPRESSIVE STRENGTH
(Cent i nued)
CONTRACTOR: BUTLER CONSTRUCTION
CONCRETE SUPPLIER: PIONEER
PLANT: 22
SPECIFICATION REQUIREMENTS
STRENGTH: 3000psi @ 28 DAYS
SLUMP: 5"
AIR: 3-6%
METHOD OF TEST: ASTM C-39
PROJECT DATA
MIX DESIGN NUMBER: 933:.
DATE OF PLACEMENT: 2/0
TIME SAMPLED: 08:
TEMPERATURE ( I F) - AIR: 41
TRUCK NO: 296
AIR CONTENT(%): 5.0
LOCATION OF PLACEMENT:
45' North X 25' east
corner of building
CYLINDER MEASURED
MARKED SLUMP DATE
SET NO. {inches) TESTED
REPORT OF TESTS
CONCRETE COMPRESSIVE STRENGTH - 6 X '12 CYLINDERS
MAXIMUM
AGE DIAMETER AREA LOAD
{days) (in.) (sq.in.) {lbs. force)
2 1 5.00 2/12/97 7
2 2 3/05/97 28
2 3 3/05/97 28
2 4 HOLD HOLD
6.00 28.27 198820
ADDITIONALCOMMENTS:
Ten (10) gallons of water added
Technician: Abdullah Ethem
Technician
Report Distribution: MAXIM TEC
(1) Lincoln Property Co.
(1) BUTLER CONSTRUCTION [NCORP.
(1) BROCKETT-DAVIS-DRAKE, [NC.
(1) THE CITY OF COPPELL
(1) THE CITY OF COPPELL
(1) O'BRIEH ASSOCIATES, INC.
1001 LW O~ le~l Ind reports Ire for tM excl~ivs ~.e of t~ client to whom t~y ire Mdre~4d end lh~l net ~ rescue
f~l witho~ tM ~proval of tM teati~ labora~ow. T~ use of ourname m~! receive our wri~en approval. O~
apply only to the sample test~ a~/or inspected, and are no! i~ica~ive of the quantities of apparently identical or
REPORT NO.
PAGE 2
SET NO. 2
112241
/97
BY: Abdullah Ethem
CONCRETE: 48
TICKET NO: 340773
from southeast
B" parking lot
OMPRESSIVE
STRENGTH
(psi)
REMARKS
3850
LABS
<B~a~cken, B.S. Ch.E.
eject Manager
~d ex~,t in
miler products.