Loading...
Northlake 635(2)-LR 970130 (5)Ma~ 2; TECHNOLOGIES INC REPORT OF DRILLED PIER INSPECTION CLIENT: Lincoln Property Co. 500 N. AKARD, SUITE 300 ATTN= LARRY MOON Dallas, TX 75201 PROJECT: COPPELL BUSINESS CENTER WRANGLER DR. & BELTLINE RD. COPPELL, TX PROJECT NO.: 090~ REPORT NO.: 1117 DATE OF SERVICE: AUTHORIZATION: REPORT DATE: 1 / SERVICES: Perform Drilled Pier Inspection. REPORT OF INSPECTION On this date, a Maxim Technologies representative arrived scheduled to perform a Drilled Pier Inspection. See attach the inspection. Time: 6:00 am - 4:00 pm Technician: Abdullah Ethem Technician im Tech. ·Southwestem Labs ;75 Lone Star Dr. · P.O. Box 224227 Dallas, Texas 75222 Telephone: (214} 631-2700 FAX: (214) 920-1891 ,605034 30/97 =n site as sd for results of Report Distribution: MAXIM T__EC~J::Fr~N LABS (1) Lincoln Property Co. 1 Our attars ~d rel~ort8 ~re for the ex ' ' . · elot ~v .....' / TS'CH I10 LO'~ I lES INC LINCOLN PROPERTY COMPANY Project Na:0903605034 Service Date: 1/27/97 !* Dali, 2575 Lone Star Drive · P.O. Box 224227; · (214) 631-2700 * Fax (214) 920-189 D1HLLEI) PIER INSPECTION (STRAIGHT SHAFD Texas 75222 Report N~: 111708 Page 2 of 4 NOTE: SEE REPORT # 111709 FOR COMPRESSIVE STRENGTH TEST SPECIMENS. · ADDITIONAL PENETRATION NOT REQUESTED UNLESS NOTED. * · ELEVATION BY OTHERS TIME: 6:00 A.M. TO 4:00 P.M. Our letter~ and report, are for the exclusive u~e of the client to whom they are addreased and shall not be reproduced exce~ laboratory. The u~e of our name muat receive prio~ writtan approve) of Maxim Technologies. Inc. Let/em and report~ apply and are not indicative of the quantity of apparently identical or similar p~oduct~. t in full without the epprovei of the te~tlng ~nly to the ,anqfle te~ted and/or in~pected Pier identification D/5.0 D/6.0 C/4.0 C/5.0 CI6.0 C/7.0 BI8.0 Pier diameter(in)/Type 24 24 24 24 24 24 24 Depth of pier from surface(ft) 34.7 36.0 34.0 34.2 35.0 34.9 31.4 Depth bearing stratum from surface(ft) 28.0 29.9 27.9 27.7 28.7 28.0 25.3 Required penetration(ft} 6.0 6.0 6.0 6.0 6.0 6.0 6.0 Actual penetration(ft)* 6.7 6.1 6.1 6.5 6.3 6.9 6.1 Condition of bottom(wet/dry) DRY DRY DRY DRY DRY DRY DRY Plumb within tolerance(yes/no) YES YES YES YES YES YES YES # of bars/Reinforcing bar size(#) 61#6 61#6 6/#6 6/#6 6/#6 6/#6 6/#6 Length of reinforcing steel(ft) 33.3 34.7 32.4 33.0 33.8 33.8 30.2 Time drilling was completed(am/pm) 8:25a 8:40a 9:00a 9:25a 9:45a 10:00a 10:20a Time concrete was placed(am/pm) 9:00a 9:15p 9:30a 9:40a 9:55a 10:10a 10:30a Depth of pier from top of concrete(ft) 34.2 35.5 33.5 33.7 34.5 34.4 30.9 Elevation:Top of pier (ft}** 99.0 99.0 99.0 99.0 99.0 99.0 99.0 Elevation:Bottom pier (ft)** 64.8 63.5 65.5 65.3 64.5 64.6 68.1 Elevation: Top of bearing stratum(ft)** 71.5 69.6 71.6 71.8 70.8 71.5 74.2 Bearing stratum (Description) DARK GRAY SHALE Date Drilled: 1/27/97***OBSERVATION OF DRIIJ~Er} FOUNDATION CO: ~STRUCTION*** TIECN N tlLOIIEJ LINCOLN PROPERTY COMPANY Project N~:0903605034 Service Date: 1/27/97 2575 Lone Star Ddva · P.O. Box 224227 * Dallas (214) 631-2700 * Fax (214) 920-189 DRILLED PW.R INSPECTION (STRAIGHT SHAFT) Texas 75222 Report Na: 111708 Page 3 of 4 Date Drilled: 1/27/97***OBSERVATION OF DRILLED FOUNDATION COl ~STRUCTION*** Pier identification B/7.0 BI6.0 BI5.0 BI4.0 CI8.0 Fl1.3 FI2.1 Pier diameter(in)/Type 24 24 24 24 24 24 24 Depth of pier from surface(ft) 38.3 33.4 35.2 34.2 34.1 31.2 31.0 Depth bearing stratum from surface(ft) 32.0 27.0 28.7 28.0 28.0 25.0 25.0 Required penetration(fi) 6.0 6.0 6.0 6.0 6.0 6.0 6.0 Actual penetration(ft)* 6.3 6.4 6.5 6.2 6.1 6.2 6.0 Condition of bottom(wet/dry) DRY DRY DRY DRY DRY DRY DRY Plumb within tolerance(yes/no) YES YES YES YES YES YES YES # of bars/Reinforcing bar size(//) 6/#6 6///6 61//6 6/#6 6///6 6///6 6///6 Length of reinforcing steel(ft) 37.1 32.2 34.0 33.0 33.0 30.4 30.5 Time drilling was completed(am/pm) 12:20p 1:15p 1:00p 12:40p 1:20p 2:00p 2:15p Time concrete was placed(am/pm) 12:30p 1:25p 1:05p 12:50p 1:35p 2:15p 2:25p Depth of pier from top of concrete(ft) 37.8 32.9 34.7 33.7 33.6 31.2 31.0 Elevation:Top of pier (ft)'' 99.0 99.0 99.0 99.0 99.0 95.5 95.5 Elevation:Bottom pier (~)°' 61.2 66.1 64.3 65.3 65.4 64.3 64.5 Elevation: Top of bearing stratum(ft)** 67.5 72.5 70.8 71.5 71.5 70.5 70.5 Bearing stratum (Description) DARK GRAY SHALE NOTE: TIME: SEE REPORT # 111709 FOR COMPRESSIVE STRENGTH TEST SPECIMENS. ADDITIONAL PENETRATION NOT REQUESTED UNLESS NOTED. ELEVATION BY OTHERS 6:00 A.M. TO 4:00 P.M. Our letters and reports are for the exclusive tm. of the client to whom they .are addre~ed.ancl.shal! not be ,el~. oduc .ed ex.c~ laboratory. The uae of our name must receive prior written a~orovai of Max~m Technologm~, inc. Lettem an~ reporm apply and are not indicative of the quantity of apparently identical o~ similar product~. t in full without the approval of the tearing only to the sample te~ted and/or inspected TECNMGLO&IES IM¢ LINCOLN PROPERTY COMPANY Project N°:0903605034 Service Date: 1/27/97 2575 Lone Star Drive · P.O. Box 224227 · Dallal Texas 75222 (214) 631-2700 * Fax (214} 920-189 DRII~LED plle~R INSPECTION (STRAIGHT SHAFT) Report N°: 111708 Page 4 of 4 Date Drilled: 1/27/97***OBSERVATION OF DRILLED FOUNDATION CO ~STRUCTION*** Pier identification F/2.7 eE. 1/6.4 eE.216.4 eE.3/6.4 eE.4/6.4 Pier diameter(in)/Type 24 18 18 18 18 Depth of pier from surface(ft) 31.2 30.4 32.0 31.1 32.6 Depth bearing stratum from surface(ft) 24.0 24.0 25.4 24.2 26.4 Required penetration(ft} 6.0 6.0 6.0 6.0 6.0 Actual penetration(ft}* 7.2 6.4 6.6 6.9 6.2 Condition of bottom(wet/dry) DRY DRY DRY DRY DRY Plumb within tolerance(yes/no} YES YES YES YES YES //of bars/Reinforcing bar size(//) 6///6 41//5 4I//5 4///5 4/#5 Length of reinforcing steel(ft) 30.8 29.3 31.0 30.0 31.7 Time drilling was completed(am/pm} 2:20p 8:20a 8:40a 9:00a 9:25a Time concrete was placed(am/pm) 2:25p 8:45p 9:00a 9:10a 9:35a Depth of pier from top of concrete(ft} 31.2 29.9 31.5 30.6 32.1 Elevation:Top of pier (ft)'* 95.5 95.5 95.5 95.5 95.5 Elevation:Bottom pier (ft)° ° 64.3 65.6 64.0 64.9 63.4 Elevation: Top of bearing stratum(ft} · · 75.5 72.0 70.6 71.8 69.6 Bearing stratum (Description) DARK GRAY SHALE NOTE: SEE REPORT # 111709 FOR COMPRESSIVE STRENGTH TEST SPECIMENS. * ADDITIONAL PENETRATION NOT REQUESTED UNLESS NOTED. * * ELEVATION BY OTHERS TIME: 6:00 A.M. TO 4:00 P.M. eBUILDING "C' SCREEN WALL Our letters and reports are for the exclusive use of the client to whom they are acldre~$ed end shall not be reproduced exc~ laboratory. The u.e of our name nn~st receive prior written approval of Maxim Technclogie~, Inc. Let/em end'reports appl and are not indicative of the quantity of apparendy identical or similar product,. ~t in full without the epproval of the tearing only to the sample tested and/or in~Rected