Northlake 635(2)-LR 970122 (5)Mm
2;
TECHNOLOGIES INC
CLIENT:
PROJECT:
SERVICES:
REPORT OF
WATER INJECTION INSPECTION
Lincoln Property Co.
500 N. AKARD, SUITE 300
ATTN= LARRY MOON
Dallas, TX 75201
COPPELL BUSINESS CENTER
WRANGLER DR. & BELTLINE RD.
COPPELL, TX
PROJECT NO.: 090,'
REPORT NO.: 1111
DATE OF SERVICE:
AUTHORIZATION:
REPORT DATE: 1/
Perform Water Injection Inspection.
REPORT OF INSPECTION
On this date, a Maxim Technologies representative performs
Injection Inspection. The result of this inspection is att
Time= 7:30 am - 9:00 am
10:00 am - 3:30 pm
Technician: David King
Technician
Report Distribution: MAXIM TEl
(1) Lincoln Property Co.
(1) BUTLER CONSTRUCTION [NCORP.
(1) 8ROC~ETT-DAV[S-DRAKE, INC.
(1) THE CITY OF COPPELL
(1).THE C]TY 0F C0PPELL
1099 FR Our lettem end reports me for the e~(clu~ive u~ of the client to whom they ~'1 ad.dressed I~nd .h~| net b? re/~rod, u
:im Tech. · Southwestern Labs
;75 Lone Star Dr. · P.O. Box 224227
Dallas, Texas 75222
Telephone: (214) 631-2700
FAX: (214) 920-1891
1605034
83
t/16/97
22/97
~ a Water
ached.
TECNMOLQGIES iNC
LINCOLN PROPERTY CO.
Project N°:0903605034
Service Date:01 / 16/97
2575 Lone Star Ddve · P.O. Box 224227 · Della B, Texas 75222
(214) 631-27OO · Fax (21'4) 920-18!~1
On January 16, 1997 a representative of MAXIM TECHNOLOGIES, IN(
injection of water into the building subgrade for compliance with project speci
was observed.
Report Ne: 111183
Page 2 of 2
observed the pressure
fications. The following
of rigs probes (ea) Number
1. Injection depth intervals marked on rig.
2. Surfactant added to each load.
3. Injection pressure maintained between 50 and 200 PSI.
4. Probes forced downward in 12 to 18 inch intervals until
refusal.
5. Total depth required on injection 10 feet.
6. Spacing for injection @ a five feet maximum.
For explanation of any NO response, see REMARKS below.
Additional injection for Building A at the request of GEOTECH Lab Maxim
See attached diagraphm.
TIME: 7:30 am to 9:00 am
10:00 am to 3:30 pm
Technician: David King
Our letters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduce
of the te~ting laboratory. The use of our name rnuet receive prior written approval of Maxim Technologies, Inc.
;ample tested and/or inepected and are not indicative of the quantity of apparently identical or ein~lar producte.
NO
NO
YES
YES
Technologies Inc.
except in full without the approval
~ter~ ,nd raport~ apply m~l¥ to the
W
Zw
_~Z
W
W
w
V
w
W~
7w
r3
I