Loading...
Northlake 635(2)-LR 961224 (3)MaX 25 TECHNOLOGIES INC: CLIENT: PROJECT: SERVICES: REPORT OF WATER INJECTION INSPECTION Lincoln Property Co. 500 N. AKARD, SUITE 300 ATTN: LARRY MOON Dallas, TX 75201 COPPELL BUSINESS CENTER WRANGLER DR. & BELTLINE RD. COPPELL, TX PROJECT NO.: 0903 REPORT NO.: 1102~ DATE OF SERVICE: 1; AUTHORIZATION: REPORT DATE: 12/; PERFORM WATER INJECTION INSPECTION. REPORT OF INSPECTION ON THIS DATE, MAXIM TECHNOLOGIES REPRESENTATIVE PERFORMED INSPECTION AS SCHEDULED. SEE ATTACHED REPORT FOR RESULTS INSPECTION. TECHNICIAN TIME: 6:30AM TO 6:30PM Technician: Daniel Hernandez Technician Report Distribution: MAXIM TE{ (1) LincoLn Property Co. (1) BUTLER CONSTRUCTION IHCORP. (1) BROCI(ETT-DAVI S-DRAKE, C1) THE CITY OF COPPELL (1) THE CITY OF COPPELL // 1098 DY Our lettem m~d re~rt~ ~re fro' the exgl,,~ve u~e ~ ~ cJien~ .to wh~l ttmy ~re ~ddremed m~d. ~ not I~. fdl without 1~4 NN~ovd o/the te~ting !~tOrlf. ! ne ~me ~. ~ mu~t recew? .o~ written ~lxoym. uur ~N;4y aflly to the ~ tested ~r~oc ~N~t~, md Jo no~ indir.~e of the clu~tJe~ of ~)~rently ider, t~r~ at l m Tech. · Southwestern Labs 75 Lone Star Dr. · P.O. Box 224227 Dallas, Texoe 75222 Telephone: (214) 631-2700 FAX: (214) 920-1891 605034 :/23/96 :4/96 WATER INJECTION ~F THE H. eSOUTHWES_IEia~,N LABS --B~acken, B. S. Ch. E. oject Manager ~rs mci reporm TECHNOLOGIES INC LINCOLN PROPERTY CO. Project N~:0903605034 Service Date: 12/23/96 2575 Lone Star Ddve * P.O. Box 224227 * Daila~ (214) 631-2700 * Fax (214) 920-189 REPORT OF WATER INJECTION INSPECTION Texas 75222 Report Nu: 110236 Page 2 On December 23, 1996, a representative of MAXIM TECHNOLOGIF. S, INC. c injection of water into the building subgrade for compliance with project specific observed. 2. 3. 4. bserved the pressure ations. The following was 2 4 B Injection depth intervals marked on rig. Surfactant added to each load. Injection pressure maintained at 50 PSI. Probes forced downward in 12 to 18 inch intervals until refusal. Total depth required on injection l0 feet. Spacing for injection @ a five feet maximum. REMARKS: See attached diagram. TIME: 6:30 am to 6:30 pm Our Iotter~ and rel~ort, are for the exclusive use of the client to whom they are addressed and shall not be reprod; aOprovd of the tusting laborato~. The use of our name rn~t receive prior written .otorovei of Maxim Technologi, only to the .an~le teoted and/or ir~peoted and are not indicative of the quantity of ~9orentJy klenticd or similar iced except in full without the I. Inc. Lettar~ and reoort~ aOIdy toduct..