Loading...
Northlake 635(7)-CS 980804Halff Associates FAX i214:, 739-0005 ENGINEERS ARCHITECTS · SCIE. IISlS PLANNERS · SURVEYORS August 4, 1998 AVO 16984 Mr. Kenneth Griffin c/o Michael Martin City of Coppell :~)~ ~~/ ~/~q 255 Parkway Boulevard P.O. Box478 ~ ' \ Coppell, Texas 75019-4409 Dear Mr. Griffin, Halff Associates, Inc. would like to submit an alternative pavement design for Coppell Call Center in Northlake 635 Business Park. For the parking area, the alternative design is 5 inch thick 4000 PSI compressive strength concrete with #3 bars, 24 inch O.C.E.W. on compacted subgrade in lieu of the 5 inch thick 3000 PSI compressive strength concrete with #3 bars, 24 inch O.C.E.W. on 6 inch lime stabilized subgrade as shown in Appendix C of the CiD' of Coppell Subdivision Ordinance. For the fire lane, the altemative design is 6 inch thick 4000 PSI compressive strength concrete with #3 bars, 24 inch O.C.E.W. on compacted subgrade in lieu of the 6 inch thick 3000 PSI compressive strength concrete with #3 bars, 24 inch O.C.E.W. on 6 inch lime stabilized subgrade shown in Appendix C of the City of Coppell Subdivision Ordinance. If you have any questions or require any additional information, please contact Pat Acker or myself. Sincerely, HALFF ASSOCIATES, INC. Todd Jackson DALLAS · FORT WORTH ° HOUSTON ° McALLEN TRANSPORTATION · WATER RESOURCES - LAND DEVELOPMENT · MUNICIPAL ° ENVIRONMENTAL ° STRUCTURAL MECHANICAL · ELECTRICAL ° SURVEYING · GEOGRAPHIC INFORMATION SYSTEMS ARCHITECTURE · LANDSCAPE ARCHITECTURE ° PLANNING