Loading...
Northlake 635(7)-CS 980518H Iff Associate ENGINEERS · ARCHITECTS · SCIENTISTS PLANNERS · SURVEYORS May 18, 1998 AVO 16800 Mr. Kenneth Griffin c/o Michael Martin City of Coppell 255 Parkway Boulevard P.O. Box 478 Coppell, Texas 75019-4409 Dear Mr. Griffin, Halff Associates, Inc. would like to submit an alternative pavement design for Coppell Call Center in Northlake 635 Business Park. For the parking area, the alternative design is 5 inch thick 4000 PSI compressive strength concrete with #3 bars, 18 inch O.C.E.W. on compacted subgrade in lieu of the 5 inch thick 3000 PSI compressive strength concrete with #3 bars, 24 inch O.C.E.W. on 6 inch lime stabilized subgrade as shown in Appendix C of the City of Coppell Subdivision Ordinance. For the fire lane. the alternative design is 6 inch thick 4000 PSI compressive strength concrete with #3 bars, 18 inch O.C.E.W. on compacted subgrade in lieu of the 6 inch thick 3000 PSI compressive strength concrete with #3 bars, 24 inch O.C.E.W. on 6 inch lime stabilized subgrade shown in Appendix C of the City of Coppell Subdivision Ordinance. If you have any questions or require any additional information, please contact Pat Acker or myself. Sincerely, HALFF ASSOCIATES, INC. Todd Jackson cc: Steve Huff Ray Garrison DALLAS * FORT WORTH · HOUSTON · McALLEN TRANSPORTATION · WATER RESOURCES · LAND DEVELOPMENT o MUNICIPAL · ENVIRONMENTAL ° STRUCTURAL MECHANICAL · ELECTRICAL · SURVEYING ° GEOGRAPHIC INFORMATION SYSTEMS ARCHITECTURE ° LANDSCAPE ARCHITECTURE o PLANNING