Northlake 635(3)-CS 971121Todd Abbott Albert H. Halff Associates 8616 Northwest Plaza Drive Dallas, Texas 75225 RE: Northlake 635 Business Park Lot 1, Block l(Coppell Business Center) / Ct 'Dear Mr. Abbott: P.O. Box 478 Coppell, Texas 75019 214-462-0022 November 21, 1997 instruction Plans Michael A. Martin, E.I.T. Assistant City Engineer The City of Coppell has received and reviewed the referenced plans and has the folio ring corjmae, nt§ to offer: /1 Provide easement for water vaults · · · . .~ ~.~'r~.~d¢~.~'-- ~~.e.~ ~.t~.~e A2% slope must maintained from the property line to the back of curb n ~e']rigt~t-o~e, zp~. · ~'3, Provide additional gate valves as indicated on the water and sanitary sewer p---~ -- '"ans,~ . ,~. All Fire Department connections must be approved by the Fire Marshal. ~-- /5. Storm sewer line "A' should be turned into the direction of flow in the chanhel. /c/v r'? ,, 5.~' ~ Provide the architectural detail for the proposed guard railings on the box ~-~erts. -- ,.~. Provide a drainage profile for the proposed channel on the south side of the ~levelopment. ~'8. How will proposed wheel stops at the proposed curb opening affect the draidage (see sheet STM -2)? /9. Provide concrete rip rap a~ eqtran, ce~ of ~e 48" J~CP~in ttje. dqli~nag~e channel ~ocated on the south side of the development. ,~ &,/er~ ff~'t ~,~ ~ / . a,~0. ~' Show the location of all water and sanitary sewer crossings in the storm server profile. --tl Provide concrete caps at all storm sewer pipe size changes./7~/L2~2Y-~ ~ 7~, /12:~/' Show the 100 year hydraulic grade line in all storm sewer profiles. ~4'3. Provide storm sewer profiles for all storm sewer laterals. [,~5 J,'~ ~ ~14./The maximum allowable manhole spacing for sanitary sewer line is 500'. tneremre, an additional ~ manhole will be required on sanitary sewer line "A". /15.~/'The minimum slope for 8" sanitary sewer line is 0.34%. /16.,/"On the drainage area map show the location of the proposed drainage systerr s. /17. -~On the left turn lane detail, Sheet DD-1, the proposed pavi.n~g thickness must nl atch the thickness of Belt · /r , ' - , / 18. The proposed southern median opening on Belt Line Road may need to be b~gl;er. Please use a WB-40 dthout running over the turning radius template to determine !f a Semi-truck can turn into the site ~ median 7 to install ballard§ between the driveway and the sout channel? There are various other minor comments throughout these plans. Once the: comments have been addressed, the marked up plans along with two revised sets of plans should be re,, ubmitted to the City for review. If you should have any questions concerning these comments, please feel tee to contact me at your convenience.