Loading...
Northlake 635(7)-LR 980629CONCRETE COMPRE._.SIVE STRENGTH TES_ ENGINEERING, INC. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 05/29/1998 Report No.: 9813837 Report Date 06/29/1998 Client .No.: 71765000 Project No.: 43-2479-97 Client: Prentiss Properties Limited, Inc. Project: Calling Center COp~y Attn: David Glass Coppell, Texas 3890 W. N.W. H~3~, Suite 400 Dallas TX 75220 Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Butler Construction CONCRETE CLASS: 9337 CONCRETE SUPPLIER: Pioneer Concrete PLACEMENT DATE: 05."29/1998 BATCH TIME: 10;40 am PLANT: 22 TIME SAMPLED: 11:18 am BY: Brian Otis SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Clear, hot STRENGTH: 3000 psi ~ 28 Days TE.Xn'ERATCRE {F)- AIR 93 F CONCRETE: 102 l: SLU_MP: 5" TRUCK NO: 841 TICKET NO: 711035 AIR: N/A AIR CONTENT (%): N.'"A L-NIT WEIGHT (po0: N/A TEST METHOD: ASTM C- 143 PLACEMENT LOCATION: Piers ^STM C-172 ASTM C-39 SA.MPLE LOCATION: 0-D.4, 0-D.6, 0-D.8, 0-E.6 REPORT OF TESTS ACCUMULATIVE YARDS: 10 CYLINDER .MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FIL4,CTI..IRE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 1 1 5.75 06/05/1998 7 76270 2700 1 2 5.75 06/05/1998 7 76890 2720 Average 2710 1 3 5.75 06.-"26..."1998 28 111440 3940 1 4 5.75 06/26/1998 28 113990 4030 Average 3990 lqote: Contractor r.o~ified of high ccncre~e ~er.~era~ure. 25 gallons of wa~er added to this load. Technician time cn reporz 9813~36. Technician: Brian Otis Started: Finished: ~ Engineering, Inc. Report Distribution: (1) Prentiss Properties Limited. Inc. (1) Halff Assoc~a:es, Inc. (I) Butler Construction (1) City of Coppell Eugene Harbour (1) Alliance Architects, Inc. (1) Evert:'Butler Const. Vice President (1) Brockette Davis Drake, Inc. (1) HBC Engineering; Sir. Eugene l larbour This report is exclusively t'or thc use of tee client indicated above and shall not be reproduced except in l'ull without the written approval of liBC Engineering, Inc. 01AK Page i of 1 CONCRETE COMPRL. SIVE STRENGTH TES_ F-\'GINEERING, LNC. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 05/29/1998 Report No.: 9813866 Report Date 06/29/1998 Client No.: 71765000 Project No.: 43-2479-97 Client: Prentiss Properties Limited, Inc. Project: Calling Center COPY Attn: David Glass Coppell, Texas 3890 W. N.W. Hx;-y, Suite 400 Dallas TX 75220 Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Butler Construction CONCRETE CLASS: 53 CONCRETE SUPPLIER: Lattimore Materials PLACEMENT DATE: 05/29/1998 BATCH TIME: 1:32 pm PLANT: 7 TIME SAMPLED: 2:00 pm BY: Brian Otis SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Clear, hot STRENGTH: 3000 psi ~! 28 Days TEMPERATURE (F)-AIR 100 F CONCRETE: 94 F SLUMP: 5" TRUCK NO: 611 TICKET N'O: 7052003 AIR: N/A AIR CONTENT (%): N/A UNIT WEIGHT (pet): N/A TEST METHOD: ASTM C- 143 PLACEMENT LOCATION: Piers ASTM C- 172 ASTM C-39 SAMPLE LOCATION: 0-D.I, 0.5-D.1, 0-C.6 REPORT OF TESTS ACCUMULATIVE YARDS: 10 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SI.UMP DATE AGE I.OAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. Ibrce) (psi) TYPE 1 1 6.75 06/05/1998 7 82290 2910 1 2 6.75 06/05/1998 7 84530 2990 Average 2950 1 3 6.75 06/26/1998 28 129000 4560 1 4 6.75 06/26/1998 28 133520 4720 Average 4640 No.ze: 10 gallo, ns of water added ~c ~his load. Technician time cn reDor~ 9813865. Technician: Brian Otis Started: Finished: ~ Engineering, Inc. Report Distribution: (1) Prentiss Properties Limited, Inc. (1) l lalff Associates, Inc. { I ) Butler Construction (1) City of Coppell Eugene Harbour (I) Alliance Architects, Inc. (1) Evcrt~Butler Const. Vice President (1) Brockette Davis Drake, Inc. (1) H BC Engineering; Mr. Eugene Harbour This report is exclusively for thc use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 01AK Page I of 1