Northlake 635(7)-LR 980406CONCRETE COMPRi_ .SIVE STRENGTH TES_ ENGLNEERING, INC. 8901 Carpenter Frwy.. Suite #100 Dallas, Texas 75247 Date of Service: 03/06;:1998 Report No.: 9806633 Report Date 04,/06/1998 Client No.: 71765000 Project No.: 43-2479-97 Client: Prentiss Properties Limited, Inc. Project: Calling Center ~nn~_~~~ Attn: David Glass 3890 W. N.W. Hx~3', Suite 400 Coppell, Texas Dallas TX 75220 Services: Obtain samples of flesh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Butler Construction CONCRETE CLASS: 9351 CONCRETE SCPPLmR: Pioneer Concrete PI, AC£.X~ENT DATE: 03/06/1998 BATCHTIME: 4:00 am PLANT: 19 TIME SAMPLED: 5'00 am BY: Jimmy Atnip SPECIFICATION REQUIREMENTS WEATHERCONOmoNs: Cool, cloudy STRE.NGTm 4000 psi ~ 28 Days TE.XIPERATCR£ (F)- AIR 36 F CONCRETE: 58 F SLUMP: 5" TRUCKXO: 806 TICKETNO: 629339 AIR: 3-6% AIR CONTENT (%): 4.50 UNIT WEIGHT (pcf): N/A TEST METHOD: ASTM C-143 PLACEMENT LOCATION: Paving, southwest Pour 4 ASTM C-172 ASTM C-39 SAMPLE LOCATION: See attached diagram REPORT OF TESTS ACCUMUI.ATIVE YARDS: 60 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SI.UMP DATE AGE I,OAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 1 1 5.00 03/13/1998 7 130640 4620 1 2 5.00 03/13/1998 7 133120 4710 Average 4670 1 3 5.00 04/03/1998 28 157300 5560 1 4 5.00 04.:'03/1998 28 148980 5270 Average 5420 This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the x~Titten approval of HBC Engineering, Inc. 01AK Page 1 of 5 CONCRETE COMPR oSIVE STRENGTH TES. ENGLNEERING, LNC. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 03/06/1998 Report No.: 9806633 Report Date 04/06/1998 Client No.: 71765000 Project No.: 43-2479-97 Client: Prentiss Properties Limited, Inc. Project: Calling Center ~'~.~l~li.4y Attn: David Glass Coppell, Texas ~ 3890 W. N.W. Hx~3,, Suite 400 Dallas TX 75220 Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTILACTOR: Butler Construction CONCRETE CLASS: 9351 CONCRETE SUPPLIER: Pioneer Concrete PLACEMENT DATE: 03/06/1998 BATCH TI.TIE: 5:10 am PLANT: 19 TIttlE SAMPLED: 6:14 am BY: Jimmy Atnip SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Coo1, cloudy STRENGTH: 4000 psi ~ 28 Days TEMPERATL'RE (F)-.AIR 38 F CONCRETE: 65 F S[.UMP: 5" TRUCKNO: 556 TICKETNO: 629353 AER: 3-65'0 .AIR CONTENT (%): N/A t'N'IT WEIGHT (per}: N/A TESI METHOD: ASTM C-143 PLACEMENT LOCATION: See page 1 ASTM C- 172 ASTM C-39 SAMPLE LOCATION: See attached diagram REPORT OF TESTS ACCUMULATI".'E YARDS: 170 CYLINDER MEASURED MAXIML'M COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) {psi) TYPE 2 1 5.00 03/13/1998 7 140880 4980 2 2 5.00 03/13/1998 7 141800 5010 Average 5000 2 3 5.00 04,'03/1998 28 ! 70810 6040 2 4 5.00 04/03/1998 28 165660 5860 Average 5950 This report is exclusively for the use of the client mdicated abox e and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 01AK Page 2 of 5 CONCRF, TE COMPRt__.SIVE STRENGTH TEL_ ENGLNEERI~, INC. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Service: 03/06/1998 Report No.: 9806633 Report Date 04/'06/1998 Client No.: 71765000 Project No.: 43-2479-97 Client: Prentiss Properties Limited, Inc. Project: Calling Center COPY Atto: David Glass Coppell. Texas 3890 W. N.W. H~Lw', Suite 400 Dallas TX 75220 Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CON'I'RACTOR: Butler Construction CONCRETE CLASS: 9351 CONCRETE SUPPLIER: Pioneer Concrete PL.*,C£MENTDATE: 03/06/1998 BATCH TIME: 6:30 am PLANT: 19 T/ME SAMPLED: 7:10 am BY: Jimmy Atnip SPECIFICATION REQUIREMENTS WEATHER CO.XOmONS: Coo1, cloudy STRENGTH: 4000 psi ~ 28 Days TEMPERATURE (F) - AIR 39 E CONCRETE: 60 E SLUMP: 5" TRUCK~O: 513 TICKETNO: 629369 AIR: 3-6% AIR CO.~TENI (%): N/A t'NIT WEIGHT (pcO: N/A TEST METHOD: ASTM C- 143 PLACEMENT LOCATION: See page 1 ASTM C- 172 ASTM C-39 SAMPLE LOCATION: See attached diagram REPORT OF TESTS ACCI_'MULATIVE YARDS: 260 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 3 1 5.00 03/13/1998 7 123090 4350 3 2 5.00 03/13/1998 7 121080 4280 Average 4320 3 3 5.00 04/03/1998 28 150740 5330 3 4 5.00 04;03/1998 28 146160 5170 Average 5250 This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, [nc. 01AK Page 3 of 5 CONCRETE COMPRL_$1VE STRENGTH TE >_ EN'GLNEERING, [NC. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Date of Sel~'ice: 03/06/1998 Report No.: 9806633 Report Date 04;'06/1998 Client No.: 71765000 Project No.: 43-2479-97 Client: Prentiss Properties Limited, Inc. Project: Calling Center COPY Attn: David Glass Coppell, Texas 3890 W. N.W. Hx~2~, Suite 400 Dallas TX 75220 Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Butler Construction CONCRETE CLASS: 9351 CONCRETE SUPPI.IER: Pioneer Concrete PLACEMENTDAT£: 03/06/1998 BATCU TreE: 8:00 am PLANT: 19 TIME SAMPLED: 8:45 am BY: Jimmy Arnip SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Cool, cloudy STRENGTH: 4000 psi ~ 28 Days TEMPERATURE (F)- AIR 38 F CONCRETE: 62 F SLUMP: 5" TRUCKNO: 752 TICKETNO: 651953 AIR: 3-6% AIR CO.~TENT (%): N/A VNIT WEIGHT (pcD: N/A TEST METHOD: ASTM C-143 PLACEMENT LOCATION: See page 1 ASTM C- 172 ASTM C-39 SAMPLE LOCATION: Sec attached diagram REPORT OF TESTS ACCI_;MULATIVE YARDS: 370 CYLINDER MEASURED MAXlML'M CO.MPRESSD,'E MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 4 I 5.25 03/13/1998 7 123360 4360 4 2 5.25 03/13/1998 7 118620 4190 Average 4280 4 3 5.25 04/03/I 998 28 134620 4760 4 4 5.25 04.."03/1998 28 128350 4540 Average 4650 This report is exclusively for the use of the client indicated aboxe and shall not be reproduced except in ful! with. out the written approval of HBC Engineering, Inc. 01AK Page 4 of 5 ENGINEERING, INC 8901 Carpenter Frwy. Suite #100 Dallas, Texas 75247 Date of Service: 03/06./1998 Report No.: 9806633 Report Date 04/06./1998 Client No.: 71765000 Project No.: 43-2479-97 Client: Prentiss Properties Limited, Inc. Project: Calling Center Attn: David Glass 3890 W. N.W. HwT, Suite 400 Coppell; Texas Dallas TX 75220 Services: Obtain samples of fi-esh concrete at the placement locations, perform required field test and cast compressive strength samples. PROJECT DATA CONTRACTOR: Butler Construction CONCRETE CLASS: 9351 CONCRETE SL'PPLIER: Pioneer Concrete PLACEMENT DATE: 03."06./1998 BATCH TIME: 9:10 am PLANT: 19 TIME SAMPLED: 9:45 am BY: Jimmy Atnip SPECIFICATION REQUIREMENTS WEATHER CONDITIONS: Cool, cloudy STRENGTH: 4000 psi ~' 28 Day.,s TEMPERATURE (F)- AIR 40 F CONCRETE: 60 F SLUMP: 5" TRUCKNO: 768 TICKETNO: 629401 AIR: 3-6% AIR CONTENT (%): N/A UNIT WEIGHT (pcf): N/A TEST METHOD: ASTM C- 143 PLACEMENT LOCATION: See page [ ASTM C- 172 ASTM C-39 SAMPLE LOCATION: See attached diagram REPORT OF TESTS ACCt.:MrLATlVE YARDS: 460 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLL'MP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 5 1 5.00 03/13/1998 7 114860 4060 5 2 5.00 03/13/1998 7 116870 4130 Average 4100 5 3 5.00 04/03/1998 28 139730 4940 5 4 5.00 04/03/1998 28 141920 5020 Average 4980 Technician: Jimmy Atnip Started: 3:00 am Finished: 1 1:00 ~ Engineering, Inc. Report Distribution: (1) Prentiss Properties Limited, Inc. (1) HaltTAssociates, Inc. (1) Butler Construction ( 1 ) City of Coppel! Eugene Harbour (l) Alliance Architects, Inc. (1) EverVButier Coast. Vice President (1) Brockette Davis Drake, Inc. (l) IIBC Engineering; Mr. Eugene Harbour This report is exclusively for the use of the client indicated abox e and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 01AK Page 5 of 5