Loading...
Northlake 635(9)-LR 970410MEIRO '. IECH Client: Hooper Engineering Contractor: TAS Construction Project: Marek Brothers Systems, Inc. 1233 Lakeshore Dr. Coppell, TX Subject: Roof deck and framing Comments: Inspection & Testing Services, Inc. 2125 W. Pioneer Parkway, Suite E-1 - Grand Prairie, Texas 75051 outside of the DFVV Metroplex ( Field Inspection Report Initial roof deck inspections were completed on this date as was t~ Observations were as follows: 1. Failed, missing or otherwise nonconforming deck attachment pudd with orange paint. Deck panels were not welded adjacent to sk the skylight frames would not let deck bear on joists. 2. Deck angle splices have still not been welded at several locations walls. 3. Notches in deck support angles were splinted by adding a 1/4 enough to span the notch at some locations. These plates were one side only. Some of the notches at panel joints have not beer 4. Joist bottom chord extensions have already been welded prior locations. $. Straight joist bridging has not been anchored to walls at either e~d of building. 6. Size of plate and weld size need to be verified for spandrel connections. connections have been modified, reducing weld lengths. 7. Panel to panel connections are incomplete at several locations tl~ 8. All modified connections must have the approval of a structura2 roof girder beating points at precast panels). Ray Waldro( Phone 972/263-5521 Fax 972/988-6286 TX/OK/AR/LA) 1-800/549-6696 Report #: 97041003 Date: 04/10/97 Page 1 of 1 ~e framing inspection. [e welds were marked llight openings where ,n the north and south 1-1/2" plate just long velded on the end and splinted or spliced. to roof load at some These roughout building. engineer (ie, the low CWI