Northlake 635(9)-LR 970407 E]RO IECH Inspection & Testing Services, Inc. 2125 W. Pioneer Parkway, Suite E-1 - Grand Prairie, Texas 75051 outside of the DFW Metroplex ( Client: Hooper Engineering Contractor: TAS Construction Project: Marek Brothers Systems, Inc. 1233 Lakeshore Dr. Coppell, TX Subject: Roof deck and steel framing Comments: Field Inspection Report An additional jobsite visit was made on this date to perform visual connections including joist bearing conditions in the high roof s~ Also, roof deck attachment conditions were examined throughou Observations were as follows: Deck puddle welds and side lap screw conditions were satisfactory section. Deck support angles need additional weld to precast panel embe south wall lower level. Vertical legs of notched deck support angles at lower level we~ horizontal legs were not. Due to misalignment with panel embeds, several joist bearing b~ all around. A "minimum amount" clarification is needed for the Phone 972/263-5521 Fax 972/988.-6286 TX/OK/ARJLA) 1-800/549-6696 Report #: 97040701 Date: 04/07/97 Page 1 of 1 xtspections on welded .,ction of roof framing. the low roof section. throughout the lower ds at two locations on 'e splinted. However, ackets are not welded conditions.