Loading...
SW9701-CS 980226 Maxim Technologies Inc. 2575 Lone Star Dr. · P.O. Box 224227 Dallas, Texas 75222 T i C H N O L O 0 1 E S I N C Telephone: (214) 531-2700 FAX: (214) 920,-1891 REPORT OF CONCRETE COMPRESSIVE STRENGTH CLIENT: ABCON CONSTRUCTION Attn: Rusty Whltaker PAGE 1 OF 1 1045 E. HWY 121 Lewisville, TX 75057 PROJECT NO.: 9710310 REPORT NO.: 130325 PROJECT: Pavement Renovation -Coppell DATE OF SERVICE: 2/19/98 Texas, Various AUTHORIZATION: Rusty 119 HEARTZ REPORT DATE: 2/26/98 SERVICES: Sample concrete at location of placement, perform required field tests, prepare and test concrete compressire strength specimens. PROJECT DATA CONTRACTOR: ABCON CONTRUCTION CLASS OF CONCRETE: N/A CONCRETE SUPPLIER: Custom Crete DATE OF PLACEMENT: 2/19/98 PLANT: #1 11ME SAMPLED: 10: 20AM BY: Joe Henry Jernigan SPECIFICATION REQUIREMENTS TEMPERATURE (OegF) - AIR: 56 CONCRETE: 64 STRENGTH: 3000psi @ 28 DAYS TRUCK NO: 462 TICKET NO: N/A SLUMP: N/A AIR: N/A MEASURED SLUMP (in.}: 3.00 METHOD OF TEST AIR CONTENT(%): N/A UNIT WEIGHT(puff: N/A SAMPLING: ASTM C-172 LOCATION OF PLACEMENT: MOLDING & CURING: ASTM C31 SLUMP: ASTM C143 119 Heartz, 2 feet west of curb on sidewalk TEMPERATURE: ASTM C1064 leading up to the house. AIR CONTENT: ASTM C173 UNIT WEIGHT: N/A CAPPING/PADS: ASTM C617 TESTING: ASTM C39 REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH SET NO. TESTED {days) {in.) ~sq.in.) {Ibs. forcs) .. {psi) .FRACTURE TYPE REMARKS 1 1 2/26/98 7 6.00 28.27 92050 3260 UNBONDED CAP i 2 2/26/98 7 6.00 28.27 91570 3240 UNBONDED CAP i 3 3/19/98 28 i 4 3/19/98 28 Technician: Joe Henry Jernigan Started: 09:00AM Stopped: ll:OOAM . Technician