Loading...
Northlake 635(3)-LR 980218 (2)OF "RILLE ELLED PIER INSPEC' IO Date of Service: 02/10/1998 Report No.: 9804692 Client No.: 52617000 Project No.: 43-2452 Client: Lincoln Property Company Project: Coppell 3300 Lincoln Plaza/Larry Moon Belt Lin, 500 North Akard Street Dallas TX 75201-3394 Coppell, Drilled belled pier inspection. Services: On this date, an HBC Engineering technician arrived at the above ref jobsite as scheduled for drilled belled pier inspection. See attach recorded data. Technician Time: 6:00 am to 12:00 pm T~ehnician: Del Ratliff Report Distribution: (I) Lincoln Property Company (1) City of Coppell/Bldg. [nsp. {I) Butler Construction (I) City of Coppell/Constr. Insp. (I) O'Bricn & Associates (I) AECC, Inc. This report is cxclusivcly for thc usc of thc clicnt indicated abovc and shall not be reproduced cxcept in full without the wr~ 99SS Page 1 of 1 4747 Irving Blvd., Suite #206 Dallas, Texas 75247 .97 Report Date 02/18/1998 Business Center II ~ Rd. & Lakeshore Dr. Texas ~renced ~d sheet for Se nior Project Engineer tten approval of HBC Engincering, Inc. REPORT OF DRILLED BELLED PIERS Project: Project No.: Coppell Business Center II Belt Line Rd. & Lakeshore Dr., Coppell, Texas 43 -2452-97 4747 Irving Boulevard, Suite 206 Dallas, Texas 75247 Report No.: 9804692 Date of Service: 02/10/98 Technician: D. Ratliff Page: 1 of l Pier Identification Pier Diameter (in.) Bell Diameter (in.) Top of Pier Elevation (ft) Req. Depth From Exist. Grade (fi) Initial Depth of Pier From Existing Grade (ft) Final Depth of Pier From Existing Grade (ft) Depth From Top of Concrete (ft) Condition of Bottom (wet or dry) Plumb Within Tolerance (yes or no) Casing Diameter (in) Cased Depth (ft) PI5 24 O/5 24 N/5 24 MI5 24 K/5 Id2 [-/3 24 24 24 1_/4 24 54 54 54 95.6 95.6 16.0 16.0 15.6 15.7 16.0 16.2 13.0 13.2 Dry Dry Yes Yes N/A N/A N/A N/A 6 6 15.5 15.7 54 54 54 54 54 95.6 9~1'6 95.6 95.6 95.6 95.6 16.0 16.0 16.0 16.0 16.0 16.0 15,5 15.7 15.6 15.2 15.6 15.4 16.0 16.1 15.8 15.7 15.9 15.8 13.0 13.1 12.8 12.7 12.9 12.8 Dry Dry Dry Dry Dry Dry Yes Yes Yes Yes Yes Yes N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Reinforcing Bar Size (#) 6 6 6 6 6 6 15.5 Length of Vertical Bars (ft.) Time Drilling Was Completed 15.6 15.6 15.0 15.7 15.6 7:50 am 8:15 am 8:30 am Time Concrete Was Placed 24 24 54 54 95,6 95.6 16.0 16.0 15.7 15.6 16.0 15,9 13.0 12,9 Dry Dry Yes Yes N/A N/A N/A N/A 6 6 15,7 15.6 9:15 am 9:20 am 9:25 am 8:45 am 9:00 am 8:00 am 9:30 am 11:30 am 9:35 am 8:20 am 8:40 am 9:00 am 9:15 am 9:54am : 11:00am 11:10ami 11:20am