Loading...
Northlake 635(3)-LR 980309CONCRETE COMPR . SIVE STRENGTH TES. Date of Service: 02/27/1998 Client No.: 52617000 Client: Lincoln Property Company 3300 Lincoln Plaza/Larry Moon 500 North Akard Street Dallas TX 75201-3394 Report No.: 9806082 Project No.: 43-2452- Project: Coppell Belt Lin, Coppell, Services: Obtain samples of fresh concrete at the placement locations, perform requir~ compressive strength samples.** SLUMP: AIR: TEST METHOD: CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer Concrete PLANT: 22 SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi ~ 28 Days 5" N/A ASTM C- 143 ASTM C- 172 ASTM C-39 PROJECT DATA CONCRETE CLASS: 9349 PLACEMENT DATE: 02/27/1998 TIME SAMPLED: 9:23 am BY: g WEATHER CONDITIONS: Clear, mi TEMPERATURE (F) - AIR 58 F C( TRUCK NO: 410 XICm~' AIR CONTENT (%): N/A UNr PLACEMENT LOCATION: Building A slab, llAto I1C, llAto HA, IlC SAMPLE LOCATION: 9.5 at A.5 CYLINDER MARKED SET NO. REPORT OF TESTS MEASURED MAXIMUM SLUMP DATE AGE LOAD (inches) TESTED (days) (lbs. force) 1 1 5.50 03/06/1998 7 110090 I 2 5.50 03/06/1998 7 105840 Average I 3 5.50 03/27/1998 28 1 4 5.50 03/27/1998 28 AC Note: Concrete placement was shut down by Owner and contractor becau subgrade was too wet. Note: Due to location of pump truck, samples were taken from concret This report is exclusively tbr the use of the client indicated above and shall not be reproduced except in full without the writl 01AK Page I of 2 8901 Carpenter Frwy., Suite gl{H} Dallas, Texas 75247 97 Report Date 03/09/1998 3usiness Center II Rd. & Lakeshore Dr. Texas :d field test and cast BATCH TIME: 8:20 am · ian Otis Id ~NCRETE: 64 g NO: 634073 'WEIGHT (oct3: N/A ~ 8C ~UMULATIVE YARDS: :OMPRESSIVE STRENGTH (psi) 3890 3740 3820 70 FRACTURE TYPE se the e trucks, en approval of HBC Engineering, Inc. 'CONCRETE COMPR . SIVE STRENGTH Date of Service: 02/27/1998 Client No.: 52617000 Client: Lincoln ProPerty Company 3300 Lincoln Plaza/Larry Moon 500 North Akard Street Dallas TX 75201-3394 Report No.: 9806082 Project No.: 43-2452. Project: Coppell Belt Lin Coppell, Services: Obtain samples of fresh concrete at the placement locations, perform requiv compressive strength samples.** SLUMP: AIR: TEST METHOD: CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer Concrete PLANT: 22 SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi ~ 28 Days 5" N/A ASTM C- 143 ASTM C- ! 72 ASTM C-39 SAMPLE LOCATION: 7.5 at B.5 CYLINDER MEASURED MARKED SLUMP SET NO. (inches) 2 I 5.00 2 2 5.00 2 3 5.00 2 4 5.00 PROJECT DATA CONCRETE CLASS: 9349 PLACEMEWr DATE: 02/27/1998 TIME SAMPLED: 10:00 am BY: B WEATHER CONDITIONS: Clear, mi TEMPERATURE (F) - AIR 58 F TRUCK NO: 802 TICKE AIR CONTENT (%): N/A UN! PLACEMENT LOCATION: See page I REPORT OF TESTS ·. MAXIMUM DATE AGE LOAD TESTED (days) (lbs. force) 03/06/1998 7 94360 03/06/1998 7 90440 Average 03/27/1998 28 03/27/1998 28 AC Note: See page 1 Technician: Brian Otis Report Distribution: (I) Lincoln Property Company (I) Butler Construction { I) O'Brien & Associates (I) AECC, Inc. Started: 7:30 am Finished: 12:00 I--~ (l) City of Coppell/BIdg. insp. ( I ) City of Coppell/Constr. insp. This report is exclusively tbr tile usc of the client indicated above and shall not be reproduced except in thll without the wi ENGINEERING, INC. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 97 Report Date 03/09/1998 3usiness Center II :Rd. & Lakeshore Dr. Texas ~d field test and cast BATCH TIME: 9:15 am rian Otis Id )NCRETE: 66 V rNO: 634080 r WEIGHT (pcO: N/A 2UMULATIVE YARDS: 2OMPRESSIVE STRENGTH (psi) 3340 3200 3270 170 FRACTURE TYPE :~ugene Harbour Vice President ten approval of HBC Engineering, Inc. 01AK Page 2 of 2