Loading...
SW9701-CS 980318TE(:HNOLOGIES IN(: Maxim Technologies Inc. 2575 Lone Star Dr. · P.O. Box 224227 Dallas, Texas 75222 Telephone: (214) 631-2700 FAX: (214) 920-1891 CLIENT: PROJECT: SERVICES: REPORT OF CONCRETE COMPRESSIVE STRENGTH ABCON CONSTRUCTION Attn: Rusty Whitaker 1045 E. HWY 121 Lewisvilla, TX 75057 Pavement Renovation -Coppall Texas, Various 415 CAMBRIA PAGE I OF i PROJECT NO.: 9710310 REPORT NO.: 131192 DATE OF SERVICE: 3/11/98 AUTHOSIZATION: Rusty 8EPORT DATE: 3/18/98 Sample concrete at location of placement, perform required field tests, prepare and test concrete compressive strength specimens. CONTRACTOR: ABCON CONTRUCTION CONCRETE SUPPLIER: Custom Crete PLANT: #1 SPECIFICATION REQUIREMENTS STRENGTH: 3000psi @ 28 DAYS SLUMP: 3-5" AIR: N/A METHOD OF TEST SAMPLING: ASTM C-172 MOLOING & CURING: ASTM C31 SLUMP: ASTM C143 TEMPERATURE: ASTM CLO64 AIR CONTENT: ASTM C173 UNIT WEIGHT: N/A CAPPING/PADS: ASTM C617 TESTING: ASTM C39 CYLINDER MARKED DATE SET NO. TESTED 1 i 3/18/98 i 2 4/08/98 I 3 4/08/98 i 4 HOLD PROJECT DATA DATE OF PLACEMENT: 3/11/98 TIME SAMPLED: 12: 50PM BY: Joe Henry Jernigan TEMPERATURE (OegF) - AIR: 44 CONCRETE: 62 TRUCK NO: 420 nCKET NO: N/A MEASURED SLUMP (in.): 5 · 00 AIR CONTENT(%): N/A UNIT WEIGHT(pcf): N/A LOCATION OF PLACEMENT: 415 Cambria sidewalk 5 feet from front door. REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS MAXIMUM COMPRESSIVE AGE DIAMETER AREA LOAD STRENGTH {days) (in,) (so.in.) {Ibs. force) (OSi) FRACTURE TYPE 7 6.00 28.27 67050 2370 UNBONDED CAP 28 28 REMARKS Technician: Joe Henry Jernigan Technician Report Distribution: 1ool DY Started: ll:OOAM Stopped: 01:00PM