Loading...
Northlake 635(3)-LR 980428REPORT OF DRILLEIr"3ELLED PIER INSPEC' IO5 Date of Service: 04/17/1998 Report No.: Client No.: 52617000 Project No.: Client: Lincoln Property Company Project: 3300 Lincoln Plaza/Larry Moon 500 North Akard Street Dallas TX 75201-3394 Drilled belled pier inspection. Services: 9810003 43-2452-! Coppell E Belt Line Coppell, On this date, an HBC Engineering technician arrived at the above ref~ jobsite as scheduled for drilled belled pier inspection. See attache recorded data. Technician Time: 6:00am to 6:00pm Technician: Brian Otis Report Distribution: (I } Lincoln Property Company (I) Butler Construction (I) O'Bricn & Associates (I) AECC, Inc. (I) City ofCoppell/Bldg. Insp. (I) City ofCoppell/Constr, lnsp. (I) Mullen & Powell Tochnistructures This report is exclusively for the use of the client indicated above and shall not bc reproduced except in full without tl~ writt 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 ~7 Report Date 04/28/1998 usiness Center II Rd. & Lakeshore Dr. ?exas cenced sheets for ~ E~-'~ring, Inc. Pat ~I D. Smith, P.E. Sen or Project Engineer m approval ofHBC Engimmring, In~. 99MP Page 1 of I REPORT OF DRILLED BELLED PIERS ENGINEERING, INC. Sg01 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Project: Project No.: Coppell Business Center II, Building #A Belt Line Rd. & Lakeshore Dr. Coppell, Texas 43 -2452-97 Report No.: 9810003 Date of Service: 04/17/1998 Technician: Brian Otis Page 1 of 2 Pier Identification Pier Diameter (in.) Bell Diameter (in.) Top of Pier Elevation (ft) Req. Depth From Exist. Grade (ft) Initial Depth of Pier From Existing Grade (ft) Final Depth of Pier From Existing Grade (ft) Depth From Top of Concrete (ft) Condition of Bottom (wet or dry) Plumb Within Tolerance (yes or no) Casing Diameter (in) Cased Depth (fi) Number of Vertical Bars (es,) Reinforcing Bar Size (#) Length of Vertical Bars (ft.) Time Drilling Was Completed Time Concrete Was Placed 11-A 24 11-D 24 11 -D.5 24 11-E 24 10.5-E 24 10,1-E 24 54.0 54.0 60.0 60.0 60.0 54.0 95.0 95.5 95.5 95.5 95.5 95.5 14.0 14.0 14.0 14.0 14,0 14.0 9.5-E 24 54.0 97.5 14.0 9-E 60,0 97.5 14.0 8.5-E 24 54.0 97.5 14.0 14.0 14.0 14.0 14.0 14.3 14~0 14.0 14.0 14.5 14.0 14.1 14.8 14.5 14.4 14.0 14,3 14,3 14.6 13.0 12.1 12.8 14.5 12.4 12.0 13.3 13.3 13.6 DRY DRY DRY DRY DRY DRY DRY DRY DRY YES N/A N/A YES YES N/A N/A 12.0 N/A YES N/A N/A 11.5 YES N/A N/A 11.5 N/A YES N/A N/A 13.0 YES N/A N/A YES N/A N/A 12.8 12.3 12.5 14.0 YES N/A N/A 13.1 24 24 60.0 54.0 97.5 97.5 14.0 14.0 14.4 14.0 14.4 14.0 13.4 13.0 DRY DRY YES YES N/A N/A N/A N/A 6 6 6 6 12.9 12.5 07:55 AM 11:15 AM 08:15 AM : 01:23 AM 08:40 AM 11:30 AM 08:55 AM 11:45 AM 09:15 AM 12:35 PM 09:30 AM 12:44 PM 09:45 AM 12:56 PM 10:30 AM 03:45 PM 10:45 AM 03:50 PM 11:05AM 03:58 PM 11:20 AM 04:10 PM REPORT OF DRILLED BELLED PIERS 8901 Carpenter Frwy., Suite Dallas, Texas 75247 Project: Project No.: Coppell Business Center II, Building #A Belt Line Rd. & Lakeshore Dr. Coppell, Texas 43-2452-97 Report No.: 9801003 Date of Service: 04/17/1998 Technician: Brian Otis Page 2 of 2 Pier Identification 7-E 6.5-E 6-E 5.5-E 1-E Pier Diameter (in.) Bell Diameter (in.) Top of Pier Elevation (ft) Req. Depth From Exist. Grade (ft) Initial Depth of Pier From Existing Grade (fi) Final Depth of Pier From Existing Grade (fi) Depth From Top of Concrete (ft) Condition of Bottom (wet or dry) Plumb Within Tolerance (yes or no) Casing Diameter (in) Cased Depth (fi) Number of Vertical Bars (ea.) Reinforcing Bar Size (#) Length of Vertical Bars (ft.) Time Drilling Was Completed Time Concrete Was Placed 24 24 24 24 24 60.0 54.0 60.0 54.0 60.0 97.5 96.0 96,0 96.0 95.5 14.0 14.0 14.0 14.0 14.0 14.0 14.0 15.0 15.0 14.2 14.3 14.2 15.0 15.0 14.2 13.3 13.2 14.0 14.0 13.2 DRY DRY DRY DRY DRY YES YES YES YES YES N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 6 6 6 6 6 6 6 6 6 6 12.8 13.0 13.5 13.5 13.0 04:17 PM 04:25 PM 04:37 PM 04:44 PM 04:53 PM ! R PORT OF DRILLEY'3ELLED PIER INSPEC IOI Date of Service: Client No.: Client: Services: 04/20/1998 52617000 Lincoln Property Company 3300 Lincoln Plaza/Larry Moon 500 North Akard Street Dallas TX 75201-3394 Drilled belled pier inspection. Report No.: 9810163 Project No.: 43-2452-! Project: Coppell l~ Belt Line Coppell, On this date, an HBC jobsite as scheduled recorded data. Engineering technician arrived at the above refE for drilled belled pier inspection. See attache Technician Time: 6:00am to 4:30 pm Technician: Brian Otis Report Distribution: (I) Lincoln Property Company (!) Butler Construction (!) O'Bricn & Associates (1) AECC, Inc. This report is exclusively for the use oftbe client indicated above and shall not be r~produced except in full without the writ~ (I) City of Coppcll/Bldg. lnsp. (1) City of Coppell/Constr. lnsp. (I) Mullen & Pow¢ll Technistructures 99MP Page 1 of I 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 ~7 Report Date 04/28/1998 .usiness Center II Rd. & Lakeshore Dr. ?exas fenced sheet for I-]~ En~ring, Inc. Pa,,l D. Smith, P.E. Sen ior Project Engineer ~n approval ofHBC Engineerin~ Inc. REPORT OF DRILLED BELLED PIERS 8901 C~rpenter Frwy., Suite #100 Dallas, Texas 75247 Project: Project No.: Coppell Business Center II-Building C Coppell, Texas 43-2452-97 Report No.: Date of Service: Technician: Page: 9810163 04/20/1998 B. Otis 1 ofl Pier Identification D.5-1 E-1.5 E-6.4 E-9.9 Pier Diameter (in.) 24 24 24 24 60.0 54.0 54.0 Bell Diameter (in.) 60.0 Top of Pier Elevation (ft) 95.5 95.5 Req. Depth From Exist. Grade (ft) 12.0 12.0 Initial Depth of Pier From Existing Grade (ft) Final Depth of Pier From Existing Grade (ft) 14.0 14.0 14.3 14.4 14.1 14.2 Depth From Top of Concrete (ft) Condition of Bottom (wet or dry) DRY DRY Plumb Wlthin Tolerance (yes or no) YES YES Casing Diameter (in) N/A NIA Cased Depth (ft) NIA NIA 96.0 95.5 12.0 12.0 14.5 14.5 14.7 14.5 14.5 14.3 DRY DRY YES' YES N/A N/A N/A N/A Number of Vertical Bare (ea.) 6 6 6 6 Reinforcing Bar Size (#) 6 6 6 6 Length of Vertical Bare (ft.) 13.58 13.67 14.0 13.83 Time Drilllng Was Completed 11:00AM 11:41 AM 12:05 PM 12:15 PM 11:48 AM Time Concrete Was Placed 11:52 AM 12:10 PM 12:20 PM CONCRETE COMPRESSIVE STRENGTH TEST Date of Service: 04/20/1998 Report No.: 981020( Client No.: 52617000 Project No.: 43-2452 Client: Lincoln Property Company Project: 3300 Lincoln PlazafLarry Moon 500 North Akard Street Dallas TX 75201-3394 Coppell Belt Lin Coppell Services: Obtain samples of fresh concrete at the placement locations, perform requi] compress ive strength samples.* * STRENGTH: SLUMP: AIR: TEST METHOD: CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer Concrete PLANT: 16 SPECIFICATION REQUIREMENTS 3500 psi ~ 28 Days 5" N/A ASTM C- 143 ASTM C- 172 ASTM C-39 PROJECT DATA CONCRETE CLASS: 9337 PLACEMENT DATE: 04/20/1998 TIME SAMPLED: 7:50 Rffl BY: WEATHER CONDITIONS: Clear, TEMPERATURE (F) - AIR 68 F ( TRUCK NO: 730 TICK AIR CONTENT (%): N/A ur PLACEMENT LOCATION: Panels 45-60, 64, 65, 69, 70-77 on Building ~ SAMPLE LOCATION: Panel 71 CYLINDER MARKED SET NO. REPORT OF TESTS MEASURED MAXIMUM SLUMP DATE AGE LOAD (inches) TESTED (days) (lin. force) 1 1 5.2-5 04/27/1998 7 127380 1 2 5.25 04/27/1998 7 123260 Average 1 3 5.25 05/18/1998 28 1 4 5.25 05/18/1998 28 This repo~ is exclusively for the use of the client indicated above and shall not be reproduced except in full without the 01AK Page 1 of 3 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 97 Report Date 04/28/1998 Business Center II e Rd. & Lakeshore Dr. Texas 'ed field test and cast BATCH TIME: 7:20 am ~ddie Elrod lnny :ONCRETE: 72 F ST NO: 702532 'IT WEIGHT (pcf): N/A CUMULATIVE YARDS: COMPRF, SSWE STRENGTH (psi) 4500 4360 4430 290 TYPE itten approval of HBC Engineering, Inc. CONCRETE COMPRL SIVE STRENGTH Date of Service: 04/20/1998 Report No.: Client No.: 52617000 Project No.: Client: Lincoln Property Company Project: 3300 Lincoln Plaza/Larry Moon 500 North Akard Street Dallas TX 75201-3394 9810201 43 -2452 Coppell Belt Lin Coppell Services: Obtain samples of fresh concrete at the placement locations, perform requi: compressive strength samples.** SLUMP: AIR: TEST METHOD: CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer Concrete PLANT: 16 SPECIFICATION REQUIREMENTS STRENGTH: 3500 psi ~ 28 Days 5" N/A ASTM C- 143 ASTM C- 172 ASTM C-39 PROJECT DATA CONCRETE CLASS: 9337 PLACEMENT DATE: 04/20/1998 TIME SAMPLED: 8:45 am BY: WEATHER CONDITIONS: Clear, TEMPERATURE (F) - AIR 70 F TRUCK NO: 752 TICKI AIR CONTENT (%): N/A UN PLACEMENT LOCATION: See page 1 SAMPLE LOCATION: Panel 74 CYLINDER MARKED SET NO. REPORT OF TESTS MEASURED MAXIMUM SLUMP DATE AGE LOAD (inches) TESTED (days) (lb~. force) 2 I 5.50 04/27/1998 7 113880 2 2 5.50 04/27/1998 7 109400 Average 2 3 5.50 05/18/1998 28 2 4 5.50 05/18/1998 28 A( This report is exclusively for the usc of thc client indicated above and shall not be reproduced except in full without thc wr 01AK Page 2 of 3 -97 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Report Date 04/28/1998 Business Center II e Rd. & Lakeshore Dr. Texas ed field test and cast BATCHTIME: 8:41 am ~die Elrod ~nny ONCRETE: 74 F :T NO: 702540 IT WEIGHT (pcf): N/A :CUMULATIVE YARDS: 370 COMPRESSIVE STRENGTH (psi) 4030 '38'70 3950 FRACTURE TYPE tten approval of HBC Engineering, Inc. ' CONCRETE COMPRI ,SIVE STRENGTH Date of Service: 04/20/1998 Client No.: 52617000 Report No.: 981020~ Project No.: 43-2452 -97 ENGINEERING, INC. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Report Date 04/28/1998 Client: Services: SLUMP: AIR: TEST METHOD: Lincoln Property Company Project: Coppell 3300 Lincoln Plaza/Larry Moon Belt Li~ 500 North Akard Street Dallas TX 75201-3394 Coppell Obtain samples of fresh concrete at the placement IDeations, perform requi] compressive strength samples.** Butler Construction Pioneer Concrete 16 CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUIREMENTS STRENGTH: 3500 psi ~ 28 Days 5" N/A ASTM C- 143 ASTM C- 172 ASTM C-39 SAMPLE LOCATION: Panel 76 DATE TESTED 04/27/1998 04/27/1998 Business Center II e Rd. & Lakeshore Dr. Texas ed field test and cast CYLINDER MEASURED MARKED SLUMP SET NO. (inches) 3 I 5.75 3 2 5.75 PROJECT DATA CONCRETE CLASS: 9337 PLACEMENT DATE: 04/20/1998 BATCH TIME: 9:10 am TIME SAMPLED: 9:25 am BY: ;ddie Elrod WEATHER COmmONS: Partly oudy TEMPERATURE (F) - AIR 72 v ¢ONCRETE: 72 v TRUCK NO: 556 TICm:T NO: 702546 AIR CONTENT (%): N/A tm IT WEIGHT (pet): N/A PLACEMENT LOCATION: See page I REPORT OF TESTS Az iCUMULATIVE YARDS: 430 MAXIMUM COMPRESSIVE AGE LOAD STRENGTH (days) (lbs. force) (psi) 7 122660 4340 7 116890 4130 Average 4240 3 3 5.75 3 4 5.75 Technician: Eddie Eirod Report Distribution: (1) Lincoln Property Company { 1) Butler Construction (l) O'Brien & Associates (1) AECC, Inc. 05/18/1998 28 05/18/1998 28 Started: 6:00 am Finished: 11:00 FRACTURE TYPE (1) City of Coppell/Bldg. Insp. (1) City of CoppelllConstr. Insp. (1) Mullen & Powell Teclmistructures This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the w~ Engineerin ~ugene Harbour Vice President tten approval of HBC Engineering, Inc. 01AK Page 3 of 3