Northlake 635(3)-LR 980529REPORT OF STRUC 'RAL STEEL INSPEC N
Date of Service: 05/20/1998
Client No.: 52617000
Client: Lincoln Property Company
3300 Lincoln Plaza/Larry Moon
500 North Akard Street
Dallas TX 75201-3394
Report No.: 981336,
Project No.: 43-2452
Project: Coppell
Belt Lk
Coppell
Services: Structural steel inspection.
On this date, an HBC Engineering representative arrived at the abov~
jobsite as scheduled for roof decking inspection on Building C. Th~
items have been visually inspected.
Between Grid Lines 1 to 4 and A to N, an inspection of the roe
conducted. 5/8" puddle . welds attached the roof to the perim(
6" centers and to the joists on 12" centers.
Side lap screws were attached in each span between joists. Dx
general notes denoted Hilti fasteners should be used. The get
contractor was in the process of checking to see if 5/8" pudd]
would be acceptable.
Technician: MetroTech
Report Distribution:
( I } Lincoln Propo~y Company
( I ! Butler Construction
( I } O'Brien & Associates
( I ) AECC, Inc.
(1) City of Coppell/BIdg insp.
(1) City of Coppoll/Constr. Insp.
(1) Mullen & Powell Technistructures
This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the va
Pal~e 1 of I