Northlake 635(3)-LR 980623.CONCRETE COMPI:L " SIVE STRENGTH Date of Service: 06/09/1998 Report No.: 981481 Client No.: 52617000 Project No.: 43-2452 Client: Lincoln Property Company Project: 3300 Lincoln Plaza/Larry Moon 500 North Akard Street Dallas TX 75201-3394 Coppell Belt Lit Coppell Services: Obtain samples of fresh concrete at the placement locations, perform requi compressive strength samples. SLUMP: AIR: TEST METHOD: CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer Concrete PLANT: 16 SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi ~ 28 Days 5" 3-5% ASTM C- 143 ASTM C- 172 ASTM C-39 PROJECT DATA CONCRETE CLASS: 9351 PLACEMENT DATE: 06/09/1998 TIME SAMPLED: 6:15 am BY: WEATHER CONDITIONS: Partly TEMPERATURE (F) - AIR 78 F ( TRUCK NO: 803 TICK3 AIR CONTENT (%): 3.0 Ur PLACEMENT LOCATION: Paving, south side of Building C SAMPLE LOCATION: 200'E/W from SEC of bldg., 25'S/N CYLINDER MARKED SET NO. REPORT OF TESTS MEASURED MAXIMUM SLUMP DATE AGE LOAD (inches) TESTED (days) (lbs. force) I 1 5.00 06/16/1998 7 110180 1 2 5.00 06/16/1998 7 106630 Average 1 3 5.00 07/07/1998 28 1 4 5.00 07/07/1998 28 Al This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the n 01AK Page I of 5 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 -97 Report Date 06/23/1998 Business Center II e Rd. & Lakeshore Dr. Texas ed field test and east BATCH TIME: 5:59 am ?erry L. Smith oudy :ONCRETE: 81 F ~TNO: 712509 IT WEIGHT (pc0: N/A .~CUMULATIVE YARDS: 60 COMPRESSIVE STRENGTH (psi) 3900 3770 3840 FRACTURE TYPE 'itten approval of HBC Engineering, Inc. ,CONCRETE COMP1Lr' SIVE STRENGTH Date of Service: 06/09/1998 Report No.: Client No.: 52617000 Project No.: Client: Lincoln Property Company Project: 3300 Lincoln Plaza/Larry Moon 500 North Akard Street Dallas TX 75201-3394 981481 43-245~ Coppell Belt Lin Coppell Services: Obtain samples o£ £resh concrete at the placement locations, perform requi~ compressive strength samples. SLUMP: AIR: TEST METHOD: CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer Concrete PLANT: 16 SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi ~ 28 Days 5" 3-5% ASTM C-143 ASTM C- 172 ASTM C-39 PROJECT DATA CONCRETE CLASS: 9351 PLACEMENT DATE: 06/09/1998 TIME SAMPLED: 7:35 am BY: ~l WEATHER CONDITIONS: Partly cl TEMPERATURE (F) - AIR 81 F C TRUCK NO: 849 TICK[ AIR CONTENT (%): 3.2 UN PLACEMENT LOCATION: See page 1 SAMPLE LOCATION: 120'E/W, 15'S/N from SEC of bldg. CYLINDER MARKED SET NO. REPORT OF TESTS MEASURED MAXIMUM SLUMP DATE AGE LOAD (inches) TESTED (days) (lbs. force) 2 1 6.50 06/16/1998 7 110390 2 2 6.50 06/16/1998 7 109210 Average 2 3 6.50 07/07/1998 28 2 4 6.50 07/07/1998 28 A£ This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the wri 01AK Page 2 of 5 ENGINEERING, INC. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Report Date 06/23/1998 -97 Business Center II e Rd. & Lakeshore Dr. Texas ed field test and cast BATCH TIME: N/A 'erry L. Smith ~udy DNCRETE: 83 F TNO: 712533 !T WEIGHT (pcf): N/A CUMULATIVE YARDS: COMPRESSIVE STRENGTH (psi) 3900 3860 3880 170 FRACTURE TYPE tten approval of HBC Engineering, inc. .CONCRETE COMPR? SIVE STRENGTH TE? Date of Service: 06/09/1998 Report No.: Client No.: 52617000 Project No.: Client: Lincoln Property Company Project: 3300 Lincoln Plaza/Larry Moon 500 North Akard Street Dallas TX 75201-3394 981481 43-2455 Coppell Belt Lip Coppell Services: Obtain samples of fresh concrete at the placement locations, perform requi compressive strength samples. CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer Concrete PLANT: 16 SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi @ 28 Days SLUMP: 5" AIR: 3-5% TEST METHOD: ASTM C- 143 ASTM C- 172 ASTM C-39 SAMPLE LOCATION: 165'W/E, 45'S/N from SWC of bldg. CYLINDER MEASURED MARKED SLUMP DATE SET NO. (inches) TESTED 3 1 6.50 06/16/1998 3 2 6.50 06/16/1998 PROJECT DATA CONCRETE CLASS: 9351 PLACEMENT DATE: 06/09/1998 TIME SAMPLED: 9:35 am BY: WEATHER CONDITIONS: Clear, TEMPERATURE (F) - AIR 84 F TRUCK NO: 849 TICK~ AIR CONTENT (%): 3.5 V~ PLACEMENT LOCATION: See page I REPORT OF TESTS MAXIMUM AGE LOAD (days) (lbs. force) 7 102700 7 98460 Average 3 3 6.50 07/07/1998 28 3 4 6.50 07/07/1998 28 At This report is exclusively for the use of the client indicated above aud shall not be reproduced except in full without the x 01AK Page 3 of 5 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Report Date 06/23/1998 -97 Business Center II e Rd. & Lakeshore Dr. Texas ed field test and cast BATCH TIME: 9:26 am ?erry L. Smith ~nny :ONCRETE: 82 F :.T NO: 712520 IT WEIGHT (pc0: N/A 2CUMULATIVE YARDS: 240 COMPRESSIVE STRENGTH (psi) 3630 3480 3560 FRACTURE TYPE 'itten approval of HBC Engineering, Inc. ,CONCRETE COMPR? SIVE STRENGTH Date of Service: 06/09/1998 Report No.: Client No.: 52617000 Project No.: Client: Lincoln Property Company Project: 3300 Lincoln Plaza/Larry Moon 500 North Akard Street Dallas TX 75201-3394 981481~ 43 -2452 Coppell Belt Lin Coppell Services: Obtain samples of fresh concrete at the placement locations, perform requi~ compressive strength samples. CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer Concrete PLANT: 16 SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi ~ 28 Days SLUMP: 5" AIR: 3-5% TEST METHOD: ASTM C- 143 ASTM C- 172 ASTM C-39 SAMPLE LOCATION: 90'W/E, 10'S/N from SWC of bldg. PROJECT DATA CONCRETE CLASS: 9351 PLACEMENT DATE: 06/09/1998 TIME SAMPLED: 10:50 am BY: WEATHER CONDITIONS: Sunny, TEMPERATURE (F) - AIR 90 F TRUCK NO: 843 TICK] AIR CONTENT (%): 3.2 UN PLACEMENT LOCATION: See page 1 REPORT OF TESTS CYLINDER MEASURED MAXIMUM MARKED SLUMP DATE AGE LOAD SET NO. (inches) TESTED (days) (lbs. force) 4 1 5.00 06/16/1998 7 108300 4 2 5.00 06/16/1998 7 112030 Average 4 3 5.00 07/07/1998 28 4 4 5.00 07/07/1998 28 A( This report is exclusively for thc use of thc client indicated above and shall not be reproduced except in full without the wr 01AK Page 4 of 5 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Report Date 06/23/1998 .97 Business Center II e Rd. & Lakeshore Dr. Texas 'ed field test and cast BATCH TIME: N/A 'erry L. Smith lear ONCRETE: 89 F ;TNO: 712545 IT WEIGHT (pcf): N/A !CUMULATIVE YARDS: 400 COMPRESSIVE STRENGTH (psi) 3830 3960 3900 FRACTURE TYPE tten approval of HBC Engineering, Inc. CONCRETE COMPRI SIVE STRENGTH TE "7 Date of Service: Client No.: Client: 06/09/1998 52617000 Lincoln Property Company 3300 Lincoln Plaza/Larry Moon 500 North Akard Street Dallas TX 75201-3394 Report No.: 9814811 Project No.: 43-2452 Project: Coppell Belt Li~ Coppell Services: Obtain samples of fresh concrete at the placement locations, perform requi~ compressive strength samples. CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer Concrete PLANT: 16 SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi ~ 28 Days SLUMP: 5" AiR: 3 -5o//0 lEST METHOD: ASTM C- 143 ASTM C- 172 ASTM C-39 SAMPLE LOCATION: 60'W/E, 45'S/N from SWC of bldg. CYLINDER MARKED SET NO. MEASURED SLUMP (inches) 5 1 5.00 5 2 5.00 5 3 5.00 5 4 5.00 PROJECT DATA CONCRETE CLASS: 9351 PLACEMENT DATE: 06/09/1998 TIME SAMPLED: 12:00 pm BY: WEATHER CONDITIONS: Sunny, TEMPERATURE (F)-AIR 92 F TRUCK NO: 725 TICm AIR CONTENT (%): 3.0 UN PLACEMENT LOCATION: See page I REPORT OF TESTS MAXIMUM DATE AGE LOAD TESTED (days) (lbs. force) 06/16/1998 7 104240 06/16/1998 7 106580 Average 07/07/1998 28 07/07/1998 28 Al Technician: Terry L. Smith Report Distribution: (1) Lincoln Property Company (1) Butler Construction (l) O'Brien & Associates (I) AECC, Inc. Started: 4:00 am Finished: 2:30 pm ~ (1) City ofCoppell/Bldg. Insp. (1) City ofCoppell/Constr. Insp. (1) Mullen & Powell Technistructures This repor~ is exclusively for the use of the client indicated above and shall not be reproduced except in full without the w~ ENGINEERING, INC. 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 -97 Report Date 06/23/1998 Business Center II e Rd. & Lakeshore Dr. Texas ed field test and cast BATCH TIME: 11:40 am 'erry L. Smith ',lear ONCRETE: 91 F :TNO: 712552 IT WEIGHT (pcf}: N/A ~CUMULATIVE YARDS: COMPRESSIVE STRENGTH (psi) 3690 3770 3730 470 FRACTURE TYPE J Eng., Inc. Eugene Harbour Vice President itten approval of HBC Enginccring, Inc. 01AK Page 5 of 5