Northlake 635(3)-LR 980812.CONCRETE COMPRr'3SIVE STRENGTH Date of Service: 07/29/1998 Report No.: 981992 Client No.: 52617000 Project No.: 43-245'. Client: Lincoln Property Company Project: 3300 Lincoln Plaza/Larry Moon 500 North Akard Street Dallas TX 75201-3394 Coppel Belt Li~ Coppel Services: Obtain samples of fresh concrete at the placement locations, perform requi compressive strength samples. CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer PLANT: 3 SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi ~ 28 Days SLUMP: 5" AIR: N/A TEST METHOD: ASTM C- 143 ASTM C- 172 ASTM C-39 PROJECT DATA CONCRETE CLASS: 935 l PLACEMENT DATE: 07/29/199~ TIME SAMPLED: 8:45 am BY: WEATHER CONDITIONS: clear TEMPERATURE (F) - AIR 85 F ~ TRUCK NO: 1884 TICK AIR CONTENT (%): N/A U1 PLACEMENT LOCATION: Parking on west side of building D. From thc approach 150'-305'. SAMPLE LOCATION: See below... CYLINDER MARKED SET NO. REPORT OF TESTS MEASURED MAXIMUM SLUMP DATE AGE LOAD (inches) TESTED (days) (lbs. force) 1 1 7.25 08/05/1998 7 86560 I 2 7.25 08/05/1998 7 87980 Average 1 3 7.25 08/26/1998 28 i 4 7.25 08/26/1998 28 Sample Location: 200'N of S approach/125'W of the face of Bldg D. This report is exclnsively lbr the use of the client indicated above and shall not be reproduced except in full without the 01AK Page i of 2 ENGINEERING, INC. 8901 ~rpenter Frwy., Suite #100 Dallas, Texas 75247 -97 Report Date 08/12/1998 Business Center II ~e Rd. & Lakeshore Dr. Texas ed field test and cast BATCH TIME: 8:20 am Eddie Elrod 7ONCRETE: 89 F ET NO: 729248 lit WEIGHT (pc0: N/A e of building to W parking curb and from S UCUMULATIVE YARDS: 230 COMPRESSIVE STRENGTH (psi) 3060 3110 3090 FRACTURE TYPE ritten approval of HBC Engineering, Inc. CONCRETE COMPRi SIVE STRENGTH Date of Service: 07/29/1998 Report No.: 9819921 Client No.: Client: Services: 52617000 Project No.: 43-2452 Lincoln Property Company 3300 Lincoln Plaza/Larry Moon 500 North Akard Street Dallas TX 75201-3394 Project: Coppell Belt Lk Coppell Obtain samples of fresh concrete at the placement locations, perform requi: compressive strength samples. CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer PLANT: 3 SPECIFICATION REQUIREMENTS STRENGTlt: 4000 psi ~ 28 Days PROJECT DATA -97 8901 C~rpenter Frwy., Suite #100 Dallas, Texas 75247 Report Date 08/12/1998 Business Center II e Rd. & Lakeshore Dr. Texas ed field test and cast CONCRETE CLASS: 9351 PLACEMENT DATE: 07/29/1998 TIME SAMPLED: 10:15 am BY: l[ddie EIrod / WEATHER CONDITIONS: clear TEMPERA~URE{F)-AIR 87 F I~ONCRETE: 88 TRUCK NO: 769 TICKI~T NO: 732759 BATCH TIME: 10:00 am F SLUMP: AIR: TEST METHOD: SAMPLE LOCATION: N/A ASTM C- 143 ASTM C- 172 ASTM C-39 See below... AIR CONTENT (%): N/A PLACEMENT LOCATION: See page I REPORT OF TESTS CYLINDER MEASURED MAXIMUM MARKED SLUMP DATE AGE LOAD SET NO. (inches) TESTED (days) (lbs. force) 2 1 8.00 08/05/1998 7 84870 2 2 8.00 08/05/1998 7 85260 Average 2 3 8.00 08/26/1998 28 2 4 8.00 08/26/1998 28 Sample Location: 275'N of S approach and 125'W of the face of Bldg U~ At Technician: Eddie Elrod Report Distribution: (I) Lincoln Property Company ( I ) Butler Construction (I) O'Bricn & Associates ( I ) AECC. Inc. Started: 7:00 am Finished: 12:00 I'~ (1) City ofCoppell/BIdg, insp. (I) City of Coppell/Constr. lnsp. (I) Mullcn & Powell Technistructures This report is exclusively Ibr thc usc of thc client indicated above and shall not be reproduced except in full without the w IT WEIGHT (pcf): N/A 2CUMULATIVE YARDS: 330 COMPRESSIVE STRENGTH (psi) 3000 3010 3010 ~ Engin~~nc. Eugene l~Farbour Vice President FRACTURE TYPE ritten approval of HBC Engineering, lnc, 01AK Page 2 of 2