Loading...
Northlake WE P10A-CS 850513GINN, INC. CONSULTING ENGINEERS May 13, 1985 Don A. Tipton 13600 LBJ Preeway, %301 Garland, Texas 75041 Re: Preliminary Plat Northlake Woodlands East No. 10 Coppell, Texas Gentlemen: Our firm has reviewed the above referenced plat for conformance to the City Subdivision Ordinance, and we-are recommending that this item be placed on the Nay 16, 1985, Planning and Zoning Commission agenda. We have the following comments: 1. Please prepare preliminamy plat in form required by Subdivision Ordinance prior to submittal to City Council. a. Complete names of adjoiner~ b. Locations, names, widths o* existing or platted streets c. Dedications and easements d. Proposed screening wall8 e. Layout, names, and widths of proposed streets Any requested variances g. Preliminary streetscape plan 2. A preliminary layout of water, sewer, and drainage has been submitted separately. Please combine this lnfor~ation with preliminary plat. 3. Please note that the lot and stceet arrangement as shown does not conform to platting requirements~ a. A minimum radius of 425~ lB required on horizontal curves except at approaches to intersections. b. Horizontal curves in sanitary sewers with radii less than 750' are not permitted. c. Block lengths cannot exceed 1200t. Please consult Subdivision and Zoning Ordinances ~nd Streetscape Plan for a ~ore co, leto list of ~equire~ents. Feel free to contact me concerning the above. Sincerely, ohn V. Wankum, P.E. -..-~,C~