Northlake WE P10A-CS 850513GINN, INC. CONSULTING ENGINEERS
May 13, 1985
Don A. Tipton
13600 LBJ Preeway, %301
Garland, Texas 75041
Re: Preliminary Plat
Northlake Woodlands East No. 10
Coppell, Texas
Gentlemen:
Our firm has reviewed the above referenced plat for conformance
to the City Subdivision Ordinance, and we-are recommending that
this item be placed on the Nay 16, 1985, Planning and Zoning
Commission agenda. We have the following comments:
1. Please prepare preliminamy plat in form required by
Subdivision Ordinance prior to submittal to City Council.
a. Complete names of adjoiner~
b. Locations, names, widths o* existing or platted streets
c. Dedications and easements
d. Proposed screening wall8
e. Layout, names, and widths of proposed streets
Any requested variances
g. Preliminary streetscape plan
2. A preliminary layout of water, sewer, and drainage has been
submitted separately. Please combine this lnfor~ation with
preliminary plat.
3. Please note that the lot and stceet arrangement as shown
does not conform to platting requirements~
a. A minimum radius of 425~ lB required on horizontal
curves except at approaches to intersections.
b. Horizontal curves in sanitary sewers with radii less
than 750' are not permitted.
c. Block lengths cannot exceed 1200t.
Please consult Subdivision and Zoning Ordinances ~nd
Streetscape Plan for a ~ore co, leto list of ~equire~ents.
Feel free to contact me concerning the above.
Sincerely,
ohn V. Wankum, P.E.
-..-~,C~