Northlake 635(5)-LR000615CONCRETE COMPREoSIVE STRENGTH TESs' Date of Service: Client No.: Client: 05/17/2000 85229000 Transwestem Property Company Attn: James Gaspard 12221 Merit Drive, g450 Dallas TX 75251 Report No.: 0013072 Project No.: 9499145 Project: Coppell ~ 1221 S. l Coppell, Services: Obtain samples of fresh concrete at the placement locations, perform requin compressive strength samples. SLUMP: AIR: TEST METHOD: CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer PLANT: 22 SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi @ 28 Days 5.0" Max N/A ASTM C- 143 ASTM C-172 ASTM C-39 SAMPLE LOCATION: P- 110 PROJECT DATA MIX I.D.: 9349 PLACEMENT DATE: 05! ! 7/2000 TIME SAMPLED: 5:00am BY: S WEATHER CONDITIONS: Cloudy,, TEMPERATURE (F) - AIR 72 F c, TRUCK NO: 1824 TICKE AIR CONTENT (%): N/A UNI PLACEMENT LOCATION: Panels- 78, 76, 77, 112, 111, 72, 60-70, 53-59, Sample taken from truck. REPORT OF TESTS AC CYLINDER MARKED SET NO. MEASURED MAXIMUM SLUMP DATE AGE LOAD (inches) TESTED (days) (lbs. force) 1 I 5.50 05/24/2000 7 86850 I 2 5.50 05/24/2000 7 89900 Average 1 3 5.50 06/14/2000 28 135960 I 4 5.50 06/14/2000 28 137950 Average This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the writ 0ILL Page 1 of 3 a division of'lfefrac~ 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Report Date 06/15/2000 ommerce Center ~eltline (Bldg. A) Texas field test and cast BATCH TIME: 4:15am :eve Campbell ¥indy )NCRETE: 78 F r NO: 567704 r WEIGHT (pcf): N/A 107, 108 2UMULATIVE YARDS: 10 2OMPRESSIVE STRENGTH (psi) 3070 3180 3130 4810 4880 4850 FRACTURE TYPE approval of HBC Engineering, Inc. CONCRETE COMPR oSIVE STRENGTH TES" Date of Service: Client No.: Client: Services: 05/17/2000 Report No.: 85229000 Project No.: Transwestem Property Company Project: Attn: James Gaspard 12221 Merit Drive,//450 Dallas TX 75251 0013072 9499145, Coppell 1221S. Coppell Obtain samples of fresh concrete at the placement locations, perform requin compressive strength samples. SLUMP: AIR: TEST METHOD: CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer PLANT: 22 SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi @ 28 Days 5.0" Max N/A ASTM C- 143 ASTM C-172 ASTM C-39 SAMPLE LOCATION: P-19 PROJECT DATA M~X I.i).: 9349 PLACEMENT DATE: 05/17/2000 TIME SAMPLED: 6:45am BY: S WEATHER CONDITIONS: TEMPERATURE (F) - AIR TRUCK NO: 108 AIR CONTENT (%): N/A PLACEMENT LOCATION: See page I Cloudy,' 72 F o TICKE UN! Sampled form truck. REPORT OF TESTS AC CYLINDER MARKED SET NO. MEASURED MAXIMUM SLUMP DATE AGE LOAD (inches) TESTED (days) (lbs. force) 2 1 7.50 05/24/2000 7 87670 2 2 7.50 05/24/2000 7 86560 Average 2 3 7.50 06/14/2000 28 113740 2 4 7.50 06/14/2000 28 116180 Average This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the writ 0ILL Page 2 of 3 a division 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 Report Date 06/15/2000 ommerce Center eltline (Bldg. A) Texas :d field test and cast BATCH TIME: 5:25am ieve Campbell vindy )NCRETE: 85 F rNO: 567714 r WEIGHT (pcf): N/A ~UMULATIVE YARDS: 10 :OMPRESSIVE STRENGTH (psi) 3100 3060 3080 4020 4110 4070 FRACTURE TYPE ~en approval of HBC Engineering, Inc. CONCRETE COMPRE" " SIVE STRENGTH TES_ Date of Service: 05/17/2000 Client No.: 85229000 Client: Transwestem Property Company Attn: James Gaspard 12221 Merit Drive, #450 Dallas TX 75251 Report No.: 0013072 Project No.: 9499145~ Project: Coppell 1221 S. ] Coppell, Services: Obtain samples of fresh concrete at the placement locations, perform requir{ compressive strength samples. SLUMP: AIR: TEST METHOD: CONTRACTOR: Butler Construction CONCRETE SUPPLIER: Pioneer PLANT: 22 SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi @ 28 Days 5.0" Max N/A ASTM C-143 ASTM C-172 ASTM C-39 SAMPLE LOCATION: P-23 PROJECT DATA MIX LO.: 9349 PLACEMENT DATE: 05/17/2000 TIME SAMPLED: 7:20am BY: SI WEATHER CONDITIONS: TEMPERATURE (F) - AIR TRUCK NO: AIR CONTENT (%): N/A PLACEMENT LOCATION: See page I Cloudy, 72 V C{ TICKE UNI Sampled from truck. REPORT OF TESTS AC, CYLINDER MARKED SET NO. MEASURED SLUMP (inches) 3 1 6.00 3 2 6.00 3 3 6.00 3 4 6.00 MAXIMUM DATE AGE LOAD TESTED (days) (lbs. force) 05/24/2000 7 111930 05/24/2000 7 108870 Average 06/14/2000 28 133300 06/14/2000 28 131450 Average Technician: Steve Campbell Report Distribution: (1) Trauswestem Property Company (1) O'Brion & Associates (1) Technistructures, Inc. (1) Butler Construction Started: 3:00am Finished: 10:00am ~ (1) City of Coppell (1) City of Coppell This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the wr a division of'lrew'~m~ 8901 Carpenter Frwy., Suite #I00 Dallas, Texas 75247 Report Date 06/15/2000 ommerce Center eltline (Bldg. A) texas I field test and cast BATCH TIME: 6:40am :ve Campbell vindy }NCRETE: 83 }~ rNO: 567718 WEIGHT (pc0: N/A UMULATIVE YARDS: 10 ~OMPRESSIVE STRENGTH (psi) 3960 3850 3910 4710 465O 4680 FRACTURE TYPE ~ugene Harbour Vice President ~en approval of HBC Engineering, Inc. 0ILL Page 3 of 3