Loading...
Northlake 635(5)-CS 990709COPPELL, TEXAS 75019 Mr. Todd Abbott, E.I.T. HalffAssociates, Inc. 8616 Northwest Plaza Dallas, TX 75225 P.O. Box 478 Coppell, Texas 75019 972-462-OO22 July 9, 1999 FILE RE: Northlake 635 Business Park, Block D Lot 1 - Coppell Commerce Center Dear Mr. Abbott: The City of Coppell has received and reviewed the referenced plans and has the following comments to offer. 1. The paving thickness and subgrade stabilization need to meet the requirements of the City Subdivision Ordinance. Variances to this ordinance can be requested via letter to the City Engineer. 2. Provide A.D.A. ramps at all driveways. 3. Clarify on all sheets the locations/boundaries of the protected areas per the Corps of Engineers 404 Permit. 4. The proposed retaining wall in the northwestern portion of the property needs to be located outside the limits of the sanitary sewer easement. Also, if this wall is being constructed with the site work (paving, grading, utilities) then the wall detail needs to be included in the plans. 5. Show all utility crossings in the storm drain profiles (use a symbol, not just text). 6. Storm sewer manholes need to be provided at 1000' spacing or less. The preferred location would be at pipe size changes to localize minor energy losses. 7. On the water and sanitary sewer plan, indicate which line goes over at all crossings. 8. Consider locating the water tap near the drive in the southeast portion of the property to keep the vault out of the slope of the swale. 9. On the left-mm lane detail: provide top of curb elevations, show double row of white reflective buttons on 30" centers for the lane markings, show roll-down curbs, provide signing for the right- turn lane and provide a caution note that a fiber optic cable is located in the median of Beltline Road. 10. Provide a traffic control plan for any work to be done in Beltline Road. Refer to the TMUTCD for guidance. There are various other comments throughout the plans. Once these comments have been addressed, these marked plans and two sets of revised plans should be submitted to the City for review. If you have any questions concerning these comments, contact me at (972) 304-7019. Sincerely, Kent M. Collins, E.I.T. Graduate Engineer