Loading...
Northlake 635(5)-CS 990616lll · ,, Halff Associates ill ENGINEERS · ARCHITECTS · SCIENTISTS PLANNERS · SURVEYORS 8616 NORTHWEST PLAZA DRIVE DALLAS, TEXAS 75225 (214) 346-6200 FAX (214) 739-0095 06-17-99Al1:02 RCVD June 16, 1999 AVO 17695 Mr. Kent M. Collins, E.I.T. City of Coppell, Engineering Dept. P.O. Box 478 Coppell, Texas 75019 RE: Northlake 635 Business Park, Lotl, Block D Dear Mr. Collins: Please find attached revised drawings for the above referenced project. For your convenience, I am providing a list of your comments and our responses. 1. Include a paving plan that should include paving dimensions and paving design (thickness, subgrade, etc) Please reference Sheet SC-1 as provided. The detailed dimensions are provided in the architectural site plan as referenced in Note 6. 2. Consider providing storm drain stub-outs to the south such that future phases can tie into the proposed system without tearing up existing concrete paving. Due to the uncertainty of the site plan for Phase II of this project, drainage tie in points have not been set. We have designed the storm system to remain flexible for future development to the south by maintaining an oversize portion of the pipe along the possible future connection points. The storm drain line has also been placed along the south side of the paving so that the impact to the existing facilities may be minimized. 3. Include profiles and all appropriate information for all sections of storm drain pipe. Please reference sheet STM-4. 4. For erosion control purposes at storm drain outfalls, consider using rock rip-rap instead of the proposed curlex blanket. DALLAS · FORT WORTH · HOUSTON · McALLEN TRANSPORTATION · WATER RESOURCES · LAND DEVELOPMENT · MUNICIPAL · ENVIRONMENTAL · STRUCTURAL MECHANICAL ° ELECTRICAL · SURVEYING · GEOGRAPHIC INFORMATION SYSTEMS ARCHITECTURE · LANDSCAPE ARCHITECTURE · PLANNING ,,, Halff Associates ENGINEERS · ARCHITECTS · SCIENTISTS PLANNERS · SURVEYORS Mr. Kent M. Collins, E.I.T. City of Coppell, Engineering Dept. June 16, 1999 Page 2 The storm drain outfalls are to be constructed using both rock rip-rap for energy dissipation and high velocity curlex blankets for the erosion protection of the disturbed areas. 5. Indicate protected areas on the plan as per the 404 wetland permit. Jurisdictional waters of the United States are referenced on Sheets 6. As per the Dallas Drainage Design Manual, concrete drainage pipe will be installed on a minimum of 0.30% grade. As discussed with Mike Martin on May 26, the 0.20% slope is a requirement resulting from the existing flow lines of the north drainage channel. The slope has been maximized for the current conditions. 7. All pipe size changes require a concrete collar. Please reference note added to Sheets STM-2, STM-3, and STM-4. 8. All fire hydrant locations need to be approved by the Fire Marshal, Travis Crump. He can be reached at (972) 304-3053. A copy of the Sheet WS-1 has been forwarded to Mr. Crump with this second submittal. 9. Show the location of the stabilized construction entrance on the erosion control plan. Please reference Sheet EC-1. 10. For the proposed left-turn lane, brick pavers need to be provided in the median noses per City Standards. Please reference Sheet LT-1. 11. The paving depth for the left-turn lanes should match the adjacent concrete paving. ,,, Halff Associates ENGINEERS · ARCHITECTS · SCIENTISTS PLANNERS ° SURVEYORS Mr. Kent M. Collins, E.I.T. City of Coppell, Engineering Dept. June 16, 1999 Page 3 The note on Sheet LT-1 instructs the contractor to match the adjacent paving thickness, with a minimum thickness of 8 inches. 12. Any work in or adjacent to Beltline Rd. will be conducted between the hours of 9am and 3pm. Please reference Sheet LT-1, Note 3. If you have any questions or require and additional information, please contact me at (214) 346- 6248. Sincerely, HALFF ASSOCIATES, INC. Todd Abbott, E.I.T. cc: Jim Gaspard, Transwestern Property Company Richard Nordyke, O'Brien & Associates