Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
121 BP Phase 1-LR000209
I:=R E~: ~" 'r'~ E~: r-i r-~ i r-i l~: i~:: i==1 i i--i E~ GEOTECHNICAL AND J ENVIRONMENTAL CONSULTANTS REPORT OF BUILT-UP ROOFING OBSERVATION 121 Business Park - Buildings B-D 601,651,701 and 751 Canyon Drive Coppell, Texas REPORTED TO: The Industrial Group REPORT NO. 158 P.O. Box 802047 REPORT DATE: 02-09-00 Dallas, Texas 75380-2047 REG PROJECT NO. 5607 A'I'TN: Mr. John Welsh DATE OBSERVED: 02-04-00 TECHNICIAN: T. Belew PAGE: 1 of 1 J General':.c'6ntractor: J Westcliffe, Inc. JWeather ContlitionS:.:J Clear/Windy JRoofing:Contra~or:J U & G Roofing Temperature RAnge: J 38°/54© J LocatiOn.of Work: J Bldg 4-Line A to F from 10 to 20 Bldg 5-Line A to F from 1 to 11 J Operations Observed::: J Bldg 4-detail work around perimeter of roof and around penetrations in roof. Bldg 5-application of a flood coat of hot asphalt covered with gravel ballast. Items observed: . ... - .Yes:" No Items Observed: .... i..':::. ...... YeS N~:: Roofing Materials As Specified: X Roof Sketch Attached: X Labels Attached: X Debris Removed from Roof Surface: X Material Sheet Attached: X Crickets Installed this Date: X Materials Stored as Required: X Deck Inspected this Date: X Non Conforming Materials Noted: × Photograph's taken this Date: X Pull Test and/or Adhesion Test Performed: X Attachments: J t ' '':~'' ..... Specified Temperatures..: .-:.:.:~ .......... . ..- -.::i~ ..... :~i.:. %:. ':- Asphal Kettle Temperature:J 500° J +/- 25 F JApplication (EVT): I 4500 I +/- 25 Actual ......... ?:' ..'.' .... :'i ..... ':" "' .: ..... Temperatures ..... Asphalt / Pitch Kettle Temperature: / TimeType III AsphaltJlO:30amI Temp' IApplicati°'n (EVT):520° Time J Temp. Distribution: (1) The Industrial Group/ Submitted by: Mr. John Walsh (1) Gromatzky Dupree & Associates/ REED ENGINEERING GROUP, INC. Mr. Bennett Foster (1) Westcliffe, Inc./Mr. Charlie Johnson Original Signed By (1) The Industrial Group/ Mr. Mac McClure Keith E. Atkins (1) Campbell Associates/ KENcav Mr. Randy Pliler (1) Bear Creek Construction/ Mr. Brian Holdgate (1) Mr. Hank Metzger 2424'-STUTZ DR. * SUITi: 400 · DALLAS. TX 75235 · TEL [2~4] 3.~'0' 5600' · FAX [214] 35'~)"~-019 ........ GEOTECHNICAL AND ! ~ I~l r-1 U F=~ ENVIRONMENTAL CONSULTANTS j REPORT OF BUILT-UP ROOFING OBSERVATION 121 Business Park - Buildings B-D 601,651,701 and 751 Canyon Drive Coppell, Texas REPORTED TO: The Industrial Group REPORT NO. 157 P.O. Box 802047 REPORT DATE: 02-09-00 Dallas, Texas 75380-2047 REG PROJECT NO. 5607 ATTN: Mr. John Welsh DATE OBSERVED: 02-03-00 TECHNICIAN: T. Belew PAGE: 1 of 1 ! Oenei;a[Cbntracto~; IWestcliffe, Inc. lwe'ath~i;'Conditi~ns:.J Clear IRoofing C~ntractor:lU & G Roofing ITemperatu~e'Range:.: J 37°/70° I Location -~ Work: I Bldg 4-Line A to F from 10 to 20 Bldg 5-Line A to F from 1 to 11 I OPerati°nsObserved: I Bldg 4-application of a flood coat of hot asphalt covered with gravel ballast. Bldg 5-preparation for gravel ballast. Items Ol$~erved: -:. ....... Yes ..No' Items Observed: .... ':-~:-:~..: Yes .N.o Roofing Materials As Specified: X Roof Sketch Attached: X Labels Attached: X Debris Removed from Roof Surface: X Material Sheet Attached: X Crickets Installed this Date: X Materials Stored as Required: X Deck Inspected this Date: X Non Conforming Materials Noted: X Photograph's taken this Date: X Pull Test and/or Adhesion Test Performed: X Attachments: X Asphai~Kettle Temperature:I 500° I +/- 25 F IApplication (EVT): I 4500 I +/-2s F Asphalt/PitchKettleTemperature: J Time Temp. IApplication(EVT): I Time ITemp. Type III Asphalt~10:35am 520c ~ Type III Asphalt 11:00am 475° Comments: Buildings 4 and 5 had Iow spots which held water, building 4 on south end and building 5 on the east and west end of building. Distribution: (1) The Industrial Group/ Submitted by: Mr. John Walsh (1) Gromatzky Dupree & Associates/ REED ENGINEERING GROUP, INC. Mr. Bennett Foster (1) Westcliffe, inc./Mr. Charlie Johnson Original Signed By (1) The Industrial Group/ Mr. Mac McClure (1) Campbell Associates/ Keith E. Atkins Mr. Randy Pliler KNcav (1) Bear Creek Construction/ Mr. Brian Holdgate (1) Mr. Hank Metzger 2424 STUTZ DR. · SUITE 400 · DALLAS. TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019 '- GEOTECHNICAL AND r~ R r-1 I I ~ ENVIRONI~ENTAL CONSULTANTS REPORT OF BUILT-UP ROOFING OBSERVATION 121 Business Park - Buildings B-D 601,651,701 and 751 Canyon Drive Coppell, Texas REPORTED TO: The Industrial Group REPORT NO. 156 P.O. Box 802047 REPORT DATE: 02-09-00 Dallas, Texas 75380-2047 REG PROJECT NO. 5607 A-I-tN: Mr. John Walsh DATE OBSERVED: 02-02-00 TECHNICIAN: T. Belew PAGE: 1 of 1 ]Genera!.:Contracto'r:tWestcliffe, Inc. IWeather Conditions:-: J Clear I Roofing.Contractor: I M & G Roofing ITemperature Rang~.,'... I 35°/58° I L°cati°n~of Work: "'l Bldg 5-Line A to F from 1 to 11 Bldg 4-Line A to F from 10 to 20 J OperatiOns"Observed: I Bldg 5-detail work and preparation of roof for gravel ballast. Bldg 4-application of a flood coat of hot asphalt covered with gravel ballast. Roofing Materials As Specified: X Roof Sketch Attached: X Labels Attached: X Debris Removed from Roof Surface: X Material Sheet Attached: X Crickets Installed this Date: X Materials Stored as Required: X Deck Inspected this Date: X Non Conforming Materials Noted: X Photograph's taken this Date: X Pull Test and/or Adhesion Test Performed: X Attachments: X Asphalt Kettle Temperature:! 500° I +/- 25 F IApplication (EVT): I 450° I +/- 25 F Asphalt / Pitch Kettle Temperature:I Time Temp. IApplication (EVT): I Time I Temp. Type III AsphaltJ2:00 pmI 525° I Type III Asphalt 2:30 pm 465° Distribution: (1) The Industrial Group/ Submitted by: Mr. John Walsh (1) Gromatzky Dupree & Associates/ REED ENGINEERING GROUP, INC. Mr. Bennett Foster (1) VVestcliffe, Inc./Mr. Charlie Johnson Original Signed By (1) The Industrial Group/ Mr. Mac McClure Keith E. Atkins (1) Campbell Associates/ KEA/cav Mr. Randy Pliler (1) Bear Creek Construction/ Mr. Brian Holdgate (1) Mr. Hank Metzger 2424 STUTZ DR. · SUITE 400 · DALLAS. TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019--