iiEPORT OF ROOFIN( NSPECTION Date of Service: 05/15/2000 Client No.: 85229000 Client: Transwestern Property Company Atto: James Gaspar ~ard 12221 Merit Drive,//450 Dallas TX 75251 Report No.: 0012893 Project No.: 94991457 Project: Coppell Commerce Center 1234 Lakeshore (Bldg. B) Coppell, Texas Report Date 06/27/2000 Services: Roofing inspection. On this date, an HBC Engineering representative arrived at the above referenced jobsite as scheduled for roofing inspection. Representatives from HEC Roofing, Johns/Manville, O'Brien & Associates, Butler Construction and HBC Engineering met to discuss the upcoming roof application for Buildings A and B. The following items were discussed. The system will be constructed with a johns/Manville four ply system, aggregate ballast, 1-inch perlite (mechanically attached), four plies of fiberglass felts and a modified SBS flashing. The roof is required to have a 1-60 wind up lift rating. However, the specifications do require that the fastener quantity be increased by 1.5 in the corners. The additional two plies of fiberglass flets will be required at all vertical flashing areas. The seam laps at the verti=al flashing and top edge areas will require a 6-inch webbing with roof cement (three course). Scuppers are to be 2 inches below the drain ring. HBC cautioned that this has been a problem with tilt wall panels, in placement. The contractor advised that corrections would be made if warranted. The curbs will be constructed in the field and will be constructed of wood. 99SS This report is exclusively for the useof Ihe client indicated ab°ye and shall n°t be repr°duccd except in M ~ ~ ~ ~ ~ ~ ~ ~ Pale 1 of 2 © O ~.: 0012893 7o 10. Per HEC, due to supply problems with asphalt, a letter has been submitted to Johns/Manville to pre-approve an additional asphalt brand to insure that the contractor has the material needed to complete the project. Tentative start up date is Monday, May 22, 2000. The contractor will be on the jobsite at approximately 6:30 a.m. daily and will work approximately 9 to 9.5 hours daily. Saturday's will be utilized only if weather has halted work during the week. Estimated days to dry-in are 19 working days on Building A and 11 days on Building B. HBC will be responsible for random spot checks. Johns/ Manville will inspect the system twice during applic~iton. HBC did receive a copy of the approved submittals on this date. NOTE: REVISED project number from 94991456 to 94991457 and project name from Coppell Commerce Center, 1221 S. Beltline (Bldg. A), Coppell, Texas to Coppell Commerce Center, 1234 Lakeshore (Bldg. B), Coppell, Texas on 06/26/00. Technician Time: 4 hours - J. Halverson/Williams Tedinichn: Terry L. Smith p~Mrt Distributioa: (I) T, uswestern Propoty Company (1) O'Bt~ & Associate~ (i) Todmisml~, Inc. (!) Butler Cot~'ucti~ (1) Cit~ of Coppcll (l) Ci~ of Vice President Paae 2 o~2