Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Northlake 635(5)-LR000218
REPORT OF DRILLED BELLED PIERS Project: Coppell Commerce Center Report No.: 0004760 1234 Lakeshore (Bldg. B), Coppell, Texas Dm o~S,rvic,: 02/18/00 Projact no.: 94991457 Tachniclan: R. Montgomery F'aae: Page 1 of 2 Pier Identification J/11 J/10 J/9 J/8 F/2 E/2 D/2 C/2 B/2 B/3 C/3 Pier Diameter (in.) 24 24 24 24 24 24 24 24. 24 24 24 Bell Diameter (in.) 54 54 54 54 54 54 54 54 54 54 54 " Top of Pier Elevation (it) 99.00 99.00 99.00 99.00 99.00 99.00 99.00 99.00 99.00 99.00 99.00 Req. Depth from Exlet. Grade (it) 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 Initial C;,p~,, of Pier fi',o~-n Ex;&~ng Grade (it) 18.00 18.50 18.50 18.58 19.83 18.92 18.58 18.75 18.00 19.00 18.33 Final I~._.;,:_.', of Pier fro,~ Grade (it) 18.58 18.58 18.75 18.67 19.92 18.92 18.58 18.75 18.00 19.00 18.58 Depth from Top of Concrete (It) 18.00 17.83 18.00 17.92 19.16 18.16 18.08 18.33 17.58 18.25 17.83 Condition of Bottom (wet o; dry) Dry Dry Dry Dry Dry Dry Dry Dry Dry Dry Dry Plumb Within Tolerance (yes or no) Yes Yes Yes Yes Yes Yes yes Yes Yes Yes Yes cesing Diameter (in) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A C,a d Depth (it) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Number of Vertical Barn les') 6 6 6 6 6 6 6 6 6 6 6 Reinforcin~l Bar Size (~ 6 6 6 6 6 6 6 6 6 6 6 ~ of Vertical B~r~ (ft.) 17.50 17.33 17.50 17.58 18.67 17.67 17.50 17.83 17.00 18.0 17.33 TimoDrfllingwasCompleted 11:43a.m. 11:32a.m. 11:23a.m. ~11:10e.m 12:50p.m. 1:00p.m. 1:20p.m. 2:40p.m. 2:18p.m., 3:25p.m. 3:35p.m. Time Concrete wee Placed, 1:48 p.m. 1:10 p.m. 1:05 p.m. 1:00 p.m. 2:10 p.m. 2:05 p.m. 2:00 p.m. 2:46 p.m. 3:30 p.m. 3:40 p.m. 3:38 p.m. I I , REPORT OF DRILLED BELLED PIERS Project: Project No.: Coppell Commerce Center 1234 Lakeshore (Bldg. B), Coppell, Texas 94991457 R. port .o.: 0004760 o.t. of Ser~c.: 02/18/00 Technician: R. Montgomery P,,ge: 2of2 , Pier Identification D/3 F_/3 F/3 Pier Diameter (in.) 24 24 24 Bell Diameter (in.) 54 54 54 Top of Pier Elevation (ft) 99.0 99.0 99.0 Req. Depth from Exist. Grade (ft} 18.0 18.0 18.0 ;nl~al ~,p;.;i of Pier from Exi~§ng Grade {ft) 18.33 18.16 18.33 Final Depth of Pier ;roi-;, Ex;~;;,,g Grade (ft) 18.42 18.33 18.33 Depth from Top of Concrete (It) 17.83 17.67 17.42 Condition of Bottom (wet or dry) Dry Dry Dry Plumb Within Tolerance (ye~ or,no) Yes Yes Yes Ca~ing Diameter (in) N/A N/A NIA C.eed Depth (ft) N/A N/A N/A Number of Vertical Barn (ea.) 6 6 6 Reinfoming Bar Size (#) 6 6 6 Length of Vertical Barn (fL) 17.33 17.00 17,00 Time Drilling, ~ Completed, , 2:45 p.m. 1:158 p.m. 1:38 p.m. Time Concrete w~ Pl~aed 3:00 p.m. 2:33 p.m. 2:21 p.m.