Park 'N Fly-PS 930617 SOUTHWEST RESEARCH iNSTITUTE
5220CULEBRAROAO · POSTOFFICt=DRAWI=R28510 · SAN ANTONIO. TEXAS. USA 78228-0510 I t210~684-$Ill · TELEX 244846
CHEMISTRY AND CHEMICAL ENGINEERING DIVlSllDN
DEPARTMENT OF FlEE TECHNOLOGY
FAX (2101 522-3377
June 17, 1993
Mr. Boris Gremont
Sun Ports International. Incorporated
8510 Sovereign Road
Dallas. Texas 75247
Subject: Flamespread Classification of Shadesure Cloth
Dear Mr. Gremont,
This comSrms your request of June 15, 1993. for additional information regarding the flamespreact
testing of the material you have identified as "Shadesum Cloth".
Testing was conducted using the procedures specified in ASTM E84-91a on April 7, 1993, u~der
SwRI Projec~ No. 01-5215-384. For this test. a flamespmad index (FSI) of 10 and a smoke
developed index (SDI) of 30 was obtained.
TI~ major building codes in the United Smms (U.B.C., BOCA and SBCCI) provide for a flame
spread classification system:
CLASS FLAMESPREAD INDEX
I 25
II 75
III 200
These classifications have also bcen rcferrcd to as A, B, and C. The smoke developed index (SDD
must be less than 450 for pm(lucts intended for use in interior finish appiica~ons.
[ hope this satisfies your request. If you have any questions, ptcase contact me at (210) 522-3632.