Loading...
Oakbend Addn-CS 890921 CITY OF COPPELL PLANNING & ENGINEERING DEPARTMENT DATE: September 21, 1989 RE: Case #ZC-523 LOCATION: STAFF REPORT FJL Near the southeast corner of State Road and Thweatt Road. APPLICANT: Mr. Jerry Lacy, Trustee Represented by Nathan Maier Engineers SURROUNDING LAND USE & ZONING: North - Single family structure, Light Industrial zoning East - Future Single family, Retail, Multi-family-2, and Planned Development Single family-9 zoning South - Vacant, Light Industrial & Single family zoning West - Vacant, Light Industrial zoning TRANSPORTATION: Freeport Parkway as proposed on the Comprehensive Thoroughfare Plan (see attached map), connects south of Coppell Road, and would join the existing Freeport Parkway Boulevard (near Bethel Road). The applicant has requested consideration of a re-alignment of Freeport Parkway, which would allow Freeport to use a reverse curve alignment to State Road, then follow State Road to Sandy Lake Road, and then curve to the northwest to the existing planned interchange with S.H. 121 Freeway. Another transportation factor to consider is State Road. In its present condition, State Road is considered as a sub-standard roadway at this time. Existing pavement is a 2-lane asphalt road, with numerous potholes along the entire length of the roadway. State Road must be improved prior to any future development. HISTORY: Property has been zoned Light Industrial prior to 1972. SIIMMARY: Applicant is requesting approval of a zoning change from Light Industrial to Single family-7 to allow for the development of single family structures. Staff recommends denial based on the following information. 1) 2) 3) ~.,adequate Bufferin§: Due to ~.~ surrounding zoning of the subject tract, (see above), if the zoning is changed to (LI) Light Industrial, each respective zone (SF-7 & LI) would be faced with the dilemma of being an inappropriate neighbor. Each use is entitled to be protected from threats to its security from the introduction of other uses. Allowing residences to enter industrial zones would not only encourage subdivisions that would make difficult the assembly of land for industrial development, but could also create a potential for complaints that would discourage industrial development. Airport Noise: This parcel boundary borders Airport Noise Zone A and Airport Noise Zone B. Aircraft landing at DFW Airport are active along this area, which would cause future homeowners to be subjected to aircraft noise. Substandard Roadways: Thweatt Road and State Road are both considered as 2-lane asphalt roadways. The impact of Oak Bend Addition to this area, would cause a greater burden on these roadways. ATTACHMENTS: l) 2) 3) Zoning exhibit District regulations Thoroughfare map ZC523STF I I I ! · --Ir I I I ! LI I I I I I I I I I I I I I I I I I I I I ! I MF-1 LI I I I _ )(R)- LI / / C 2F-9 \j) MF-2 C C --111 NATHAN D. MAIER CONSULTING ENGINEERS, INC. September 13, 1989 Ms. Taryon Bowman City of Coppell 255 Parkway Blvd. Coppell, Texas 75019 Re: Oakbend Addition NDM No.: 89-5-72 Dear Taryon: We propose the following minimum regulations for the zoning ordinance relating to the above described property. NORMAL ~F-7 REGULATION PROPOSED REGULATION Two-story/35 feet Two-story/35 feet 30 feet 30 feet TYPE OF REGULATION Maximum Building Height Minimum Front Yard Minimum Side Yard Interior Lots Corner Lots - Section 13 Comer Lots - Section 31 Minimum Rear Yard Minimum Lot Area Minimum Lot Width Minimum Lot Depth Minimum Dwelling Size Maximum Lot Coverage Maximum Off-street Parking Exterior Construction 8 feet 8 feet 15 feet 15 feet 30 feet 15 feet 20 feet 20 feet 7,O00 SF 7,600 SF 65 feet 66.5 feet 100 feet 115 feet 1,200 SF 1,600 SF 2 spaces 2 spaces 8O% 8O% These regulations require a variance to section 31 of the zoning ordinance, which required a 30-foot sideyard for comer lots. We also request the following variances from the subdivision ordinance: 1. No alleys behind creek lots. 2. Open ditches allowed along State Street and Thweat Road until each is improved. Our average lot size for this project will be 11,500 square feet. Thank you for your assistance. Sincerely, NATHAN D. MAIER CONS~LTIN~ ENGINEERS, INC. Mike Daniel, P.E., R.P.S. CMD/rdp Three NorthPark/8800 N. Central Expwy./Suite 300/Daila,, Texaa 75231/(214) 73~-4741