Oakbend Addn-CS 910523 (2)DATE:
FROM:
COPPELL PUBLIC WORKS
BY: En~ineering
May 23, 1991
Larry Davis, Construction Inspector
Howard Pafford, Water Utilities Superintendent
Oakbend Addition/Punch list
As you are aware, Utilities personnel have performed a final
walkthrough on the above referenced subdivision and have found that
all deficient punchlist items have been corrected. However, as we
have previously discussed there is a problem with the way that some
of the water service meter setters were installed. This meter
setter has been equipped with a separate inline dual check and in
reviewing the detail for acceptance of this device, I had requested
that the inline check be connected to the setter with a 3/4" close
(all thread) bronze nipple. This would allow the entire length of
the device to fit within the meter box. Based on the comments from
field personnel, longer bronze nipples were used in some of the
installations.
I have spoken with Derek Earle of Centex and he stated that he
would correct this problem by having the nipples changed out (if
necessary) at the time the plumber installs the plumbing for each
house being built in the subdivision. Therefore, I have asked Mr.
Earle to submit a letter stating that this would take place.
If you have any questions regarding this matter, please advise.
HLP/mp
cc: Steven G. Goram, Director of Public Works
OAKPUNCH. HLP