Park Meadow-LR 851217Maxim Engineers Inc. 2342 Fabens Geotechnical P.O, Bbx 59902 Materials Testing Dallas. Texas 75229 Con~l iIt~nf~ (~)! ~) 2'!7 7575 Moisture/Density Relations of Soil REVISED COPY (12/17/85) - PROJ DISTRIBUTION m m CHANGE Report Date To Project Test Procedure Method 12/17/85 S, mp~e D~te 11/08/85 Coppell Municipal Utility District c/o Pierce-Lunsford Associates, Inc. *Park Meadow II - Coppell, Texas ASTM D 698 A Resulm Rammer Type ........................ Preparation Procedure .............. Haterial Description ................ Unified Soil Classification ......... Liquid Limit Plastic Limit Plastic Index Percent Passing No. 200 Sieve ...... Maximum Dry Density ................ Optimum Moisture ................... ee®eele®eeeeeeeeeeeeee ®l®ee®eeeeeeee®ee~eee® Mechanical Moi st Dark gray and reddish brown clay intermixed with some limestone fragments and calcareous nodules CL 41 17 24 68 102.7 lbs./cu, ft. 20.2 percent '3155-411026 Technician: C.B. Coppell Municipal Utility District, c/o Pierce-Lunsford Associates, Inc. - Hawkins *Coppell Municipal Utility District, c/o Pierce-Lunsford Associates, Inc. - *Craig Goodpastor Ginn, Inc. - Steve Pennington American Developers & Contractors - Glenn Hemphill Wiseco Land Development - Tom Wise Jeff Maxim Englncere, Inc.