Parkview Addition-CS 990605TECHNOLOGIES INC
CLIENT:
PROJECT:
REPORT OF
CONCRETE COMPRESSIVE STRENGTH
ABCON CONSTRUCTION
Attn: Rusty Whitaker PAGE 1 OF 1
1045 E. HWY 121
Lewisville, TX 75057 PROJECT NO.: 9710310
REPORT NO.: 147349
Pavement Renovation -Coppel! DATE OF SERVICE: 5/08/99
Texas, Various AUTHORIZATION: Rusty
285 ALEX '~ REPORT DATE: 6/05/99
Maxim Technologies Inc.
2575 Lone Star Drive
Dallas, Texas 75222
Telephone: (214) 631-2700
FAX: (214) 920-1891
SERVICES: Sample concrete at location of placement, perform required field tests,
prepare and test concrete compressive strength specimens.
CONTRACTOR: ABCON CONTRUCTION
CONCRETE SUPPLIER: Custom Crete
PLANT: 1
SPECIFICATION REQUIREMENTS
STRENGTH: 3000psi @ 28 DAYS
SLUMP: 4"-5" AIR:
METHOD OF TEST
SAMPLING: ASTM C-172
MOLDING & CURING: ASTM C31
SLUMP: A~TM C143
TEMPERATURE: AS '1'~ C1064
AIR CONTENT: ASTM C231
UNIT WEIGHT: N/A
CAPPING/PADS: ASTM C123
TESTING: ASTM C39
1
1
1
CYLINDER
MARKED
SET NO.
1
2
3
3%-6%
PROJECT DATA
CLASS OF CONCRETE: 4
DATE OF PLACEMENT: 5/08/99
TIME SAMPLED: 07:40AM BY: Yefim Palchik,
TEMPERATURE (DegF) - AIR: 55 CONCRETE: 70
TRUCK NO: 362 TICKET NO: 170941
MEASURED SLUMP {in.): 4.00
AIR CONTENT(%): 3.1 UNIT WEIGHT(pcf): NA
LOCATION OF PLACEMENT:
Sidewalk at 285 alex, north portion
REPORT OF TESTS
CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS
DATE AGE
TESTED {days)
5/15/99 7
6/05/99 28
6/05/99 28
MAXIMUM COMPRESSIVE
DIAMETER AREA LOAD STRENGTH
(in.) {sq.in.) {lbs, force) (psi) FRACTURE TYPE
6.00 28.27 130180 4600 UNBONDED CAP
6.00 28.27 131090 4640 UN-BONDED,CAP
6.00 28.27 137860 4880 UNBONDED CAP
MSCE
REMARKS
1 4 HOLD
Technician: Yefim Palchik, MSCE
Senior Consultant
Report Distribution:
{1) ABCON CONSTRUCTION
(1) City of Copfletl
Started: 06:00AM Stopped: 08:30AM
MAXIM TECHNOLOGIES INC.
Our letters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced except in
full without the approval of the testing laboratory. The use of our name must receive our written approval. Our letters am3 reports
1001 PH apply only to the sample tested and/or inspected, and are not indicative of the quantities of apparently identical or similar products.