Loading...
Park West CC(3)-LR000405GEOTECHNICAL AND G F:=J r-i LJ F=~ ENVIRONMENTAL CONSULTANTS REPORTED TO: CONCRETE CYLINDER TEST REPORT Daryl Flood Warehouse Airline Road at Enterprise Road Coppell, Texas Daryl Flood Warehouse-Movers, Inc. 2009 Country Club Drive Carrollton, Texas 75006 ATTN: Mr. Daryl Flood REPORT NO. 65 REG PROJECT NO. 6080 SAMPLE DATE: 04-05-00 TECHNICIAN: L. Walton CONTRACTOR: McFadden & Miller, Inc. Location of Sample Set Number J Location 1 Paving: 2 Paving: 3 Paving: 4 Paving: 85'N, 10'E of the SE Bldg. corner 160'N, 35'E of the SE Bldg. corner 185'N, 45'E of the SE Bldg. corner 80'S, 165'E of the NE Bldg. corner J Quantity Represented 30~420 120~420 220/420 320~420 Design Information Source of ConcreteI TXI Mix Identification 9643 Specified Strength p.s.i. 4O0O Test Results Set Cylinder I No. ID Date Tested Age @ Test 4588 04-12-00 7 4588 05-03-00 28 4588 05-03-00 28 4588 Hold H 2 4589 04-12-O0 7 4589 05-03-00 28 4589 05-03-00 28 4589 Hold H 4590 04-12-00 7 4590 05-03-00 28 4590 05-03-00 28 4590 Hold H 4591 04-12-00 7 4591 05-03-00 28 4591 05-03-00 28 4591 Hold H J Total Load Compressive lbs. Strength p.s.i. 104660 3700 103340 3660 106250 3760 1O466O 37OO Average Strength p.s.i. 2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019 Cylinder Data Set Cylinder I Timeof I No. ID Slump Sample Air Temp. 1 4588 5.0 7:40AM 43 2 4589 4.5 8:45AM 53 3 4590 5.5 10:50AM 69 4 4591 5.0 11:40AM 70 ConcreteI Air I Ticket Temp. Entrainment Number 63 5.3 1546812 63 5.5 1546979 68 5.7 1547192 67 5.6 1547384 Distribution: (1) Daryl Flood Warehouse-Movers, Inc./ Mr. Daryl Flood (1) McFadden & Miller, Inc./ Mr. Jon Jacobson (1) Meinhardt & Quintana/ Mr. David Meinhardt (1) Halff Associates/Mr. Patrick Acker (1) City of Coppell/Mr. Larry Davis (1) City of Coppell/Mr. Lee Stone (1) Bihner Engineering/Mr. Yubo Chen Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Keith Atkins kENrt CONTRA CT INSPECTION SER vICE, Inc. 4305 Glenwood Ct. Granbury, TX 76049 (817) 246-8096 FAX (817) 246-5889 REPORT OF STRUCTURAL STEEL INSPECTION Report No: 17073-0 Attention: Keith Atkins Date of Service: 04-05-00 Project: Daryl Flood Warehouse Coppell, Texas Client: Reed Engineering Group 2424 Stutz, Suite 400 Dallas, TX 75235 Pa e ! of 1 REPORT OF INSPECTION Drawings utilized: Structural Prints/SJUAISC Locations/item inspected: Grids A - J/1 - I3 Discrepancies/comments: Structural steel inspection: 1.) Anchor bolts now comply in area E - J/! - 8. 2.) Bottom chords of girders have been welded where required. 3.) Joist tails tied in as required. Technician ~ntract Inspection Service This report is for the exclusive use of our client and shall not be modified or reproduced without written approval from said client GEOTECHNICAL AND ENVIRONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Daryl Flood Warehouse Airline Road at Enterprise Road Coppell, Texas REPORTED TO: Daryl Flood Warehouse-Movers, Inc. 2009 Country Club Drive Carrollton, Texas 75006 A'FI'N: Mr. Daryl Flood REPORT NO. 65 REG PROJECT NO. 6080 SAMPLE DATE: 04-05-00 TECHNICIAN: L. Walton CONTRACTOR: McFadden & Miller, Inc. Location of Sample ISet Number ILocation 1 Paving: 85'N, IO'E of the SE Bldg. corner 2 Paving: 160'N, 35'E of the SE Bldg. corner 3 Paving: 185'N, 45'E of the SE Bldg. corner 4 Paving: 80'S, 165'E of the NE Bldg. corner Quantity Represented 30/420 120/420 220/420 320/420 Design Information Source of Concrete I Mix Identification TXI 9643 Specified Strength p.s.i. 4OOO Test Results ISet I CylinderI Age(~ Total Load N . I ID Date Tested Test lbs. ~ 4588 04-12-00 7 104660 3700 4588 05-03-00 28 127220 4500 4588 05-03-00 28 126990 4490 4588 Hold H Compressive I Average Strength p.s.i. Strength p.s.i. 2 4589 04-12-00 7 103340 3660 4589 05-03-00 28 126640 4480 4589 05-03-00 28 126480 4470 4589 Hold H 3 4590 04-12-00 7 106250 3760 4590 05-03-00 28 136100 4810 4590 05-03-00 28 133220 4710 4590 Hold H 4 4591 04-12-00 7 104660 3700 4591 05-03-00 28 135900 4810 4591 05-03-00 28 132280 4680 4591 Hold H 4500 4480 4760 475O 2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · ~AX [214] 350 0019 Cylinder Data Set Cylinder No. ID 2 3 4 Slump Sample Air Temp. Temp. Entrainment Number 4588 5.0 7:40AM 43 63 5.3 1546812 4589 4.5 8:45AM 53 63 5.5 1546979 4590 5.5 10:50AM 69 68 5.7 1547192 4591 5.0 11:40AM 70 67 5.(~ 1547384 Distribution: (1) Daryl Flood Warehouse-Movers, Inc./ Mr. Daryl Flood (1) McFadden & Miller, Inc./ Mr. Jon Jacobson (1) Meinhardt & Quintana/ Mr. David Meinhardt (1) Halff Associates/Mr. Patrick Acker (1) City of Coppell/Mr. Larry Davis (1) City of Coppell/Mr. Lee Stone (1) Bihner Engineering/Mr. Yubo Chen Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Keith Atkins KEA/rt