Park West CC(3)-LR000308GEOTECHNICALAND ~ F:=I I'-I I I F=a ENVIRONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Daryl Flood Warehouse Airline Road at Enterprise Road Coppell, Texas REPORTED TO: Daryl Flood Warehouse-Movers, Inc. 2009 Country Club Drive Carrollton, Texas 75006 ATTN: Mr. Daryl Flood REPORT NO. 58 REG PROJECT NO. 6080 SAMPLE DATE: 03-08-00 TECHNICIAN: L, Walton CONTRACTOR: McFadden & Miller, Inc. Location of Sample Set Number I Location 1 Slab Leave Out: 65'N, 55'W of SE Bldg. Corner J Quantity Represented 10/40 Design Information Source of Concrete TXI Mix Identification 47 Specified Strength p.s.i. 4000 Test Results Set Cylinder J No. ID Date Tested Age @ Total Load Test lbs. Compressive J Average Strength Strength p.s.i.I p.s.i. 3811 03-15-00 7 3811 04-05-00 28 3811 04-05-00 28 3811 Hold 98430 3480 Cylinder Data Set Cylinder Time of N1. ID Slump Sample 3811 5,00 10:30 AM Concrete Air Ticket Air Temp. Temp. Entrainment Number 70 68 N/A 1527531 Distribution: (1) Daryl Flood Warehouse-Movers, Inc./ Mr. Daryl Flood (1) McFadden & Miller, Inc./ Mr. Jon Jacobson (1) Meinhardt & Quintana/ Mr. David Meinhardt (1) Halff Associates/Mr. Patrick Acker (1) City of Coppell/Mr. Larry Davis (1) City of Coppell/Mr. Lee Stone (1) Bihner Engineering/Mr. Yubo Chen Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Keith Atkins KEA/rt 2424 STUTZ DR. · SUITE 400 - DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019 GEOTECHNICAL AND G J==J I--I LJ F:~ ENVIRONHENTAL CONSULTANTS REPORTED TO: CONCRETE CYLINDER TEST REPORT Daryl Flood Warehouse Airline Road at Enterprise Road Coppell, Texas Daryl Flood Warehouse-Movers, Inc. 2009 Country Club Drive Carrollton, Texas 75006 ATTN: Mr. Daryl Flood REPORT NO. 58 REG PROJECT NO. 6080 SAMPLE DATE: 03-08-00 TECHNICIAN: L. Walton CONTRACTOR: McFadden & Miller, Inc. Location of Sample Set Number J Location Slab Leave Out: 65'N, 55'W of SE Bldg. Corner J Quantity Represented 10/40 Design Information Source of Concrete J TXI Mix Identification J 47 Specified Strength p.s.i. 4000 Test Results Set Cylinder I No. ID Date Tested 1 3811 03-15-00 3811 04-05-00 3811 04-05-00 3811 Hold J Age @ Total Load Test lbs. Compressive J Average Strength Strength p.s.i.J p.s.i. 7 98430 3480 28 140070 4950 28 147810 5230 5O9O Cylinder Data Set Cylinder I J Timeof I Concrete N1. ID Slump Sample Air Temp. Temp. 3811 5.00 10:30 AM 70 68 JAir Ticket Entrainment Number N/A 1527531 Distribution: (1) Daryl Flood Warehouse-Movers, Inc./ Mr. Daryl Flood (1) McFadden & Miller, Inc./ Mr. Jon Jacobson (1) Meinhardt & Quintana/ Mr. David Meinhardt (1) Halff Associates/Mr. Patrick Acker (1) City of Coppell/Mr. Larry Davis (1) City of Coppell/Mr. Lee Stone (1) Bihner Engineering/Mr. Yubo Chen Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Keith Atkins KENrt 2424 STUTZ DR. * SUITE 400 · DALLAS, TX 75235 * TEL [214] 350 5600 · FAX [214] 350 0019 CONTRA CT INSPECTION SER VICE, Inc. 4305 Glenwood Ct. Granbury, TX 76049 (817) 246-8096 FAX (817) 246-5889 REPORT OF STRUCTURAL STEEL INSPECTION Project: CHent: Daryl Flood Warehouse Coppell, Texas Reed Engineering Group 2424 Stutz, Suite 400 Report No: 16727-0 Attention: Keith Atkins Date of Service: 03-08-00 Dallas, TX 75235 Page 1 of ! REPORT OF INSPECTION Drawings utilized: Structural Prints/SJI/AISC Locations/item inspected: Grids A - J/! - 7 Grids A-J/l- 13 (anchor bolts) Discrepancies/comments: Inspection was conducted on the above referenced project in areas noted above with results as follows: 1) Areas A through B/l-7, not complete at this time. 2) Area B-J/l-7 bearing of joist and girders comply. 3) Bridging installtion and welds comply - Area B-J/l-7. 4) Perimeter angle complies B J/l-1. *5) Anchor bolts non-compliant for tensioning A-J/I-13. 6) Installation teflon slide pads comply to Detail S42-03. Note - Water in some leave outs. *Discrepancies. Technician Contract ins~ecti;n ~ervice This report is for the exclusive use of our client and shall not be modffied or reproduced without written approval from said client