Park West CC(3)-LR 991115 (2)1341 West Mocki,~gblrd Lane · Dallas, Texas 7S247 - 972.647.6700- www. txLcom November 15, 1999 McFadden & Miller, Inc. P.o. Box 5988~ 'Dallas, TX 75229 Attn= Mr. Jon Jacobsen RE: Darrell Flood Warehouse 4600 Airline Drive 0045 0046 0047 The attached concrete mix designs utilizing the appropriate ASTM C-3~ or A~TM C-3~0 aggregate are proposed for u~e on Lh~ ~tbove referenced project for ready-mixed concrete to be furnished by TXI. To ensure that the correct mix is delivered to yo~r ~roject, please order by the mix design number which appears mn the upper left hand corner of'the mix design. Texas Industries certifies that the above mix de'signs, when ordered by specifie~ d~slgn ±dentiuy, and delivereu Dy TXI, will meet.or exceed the zndzcated design strength at the.designated age when testc~ in accordance with the applicable.and current ASTM Standards C 31, C 39, C 78, C 172, C 293, applicable prov%s~on~ of C 94, and evaluated in accordance wzth applicable .provzszons of ACI Building Code. TXI would like to be included on your mailing list to receive all test reports. ASTM C 94 entitles a manufacturer to receive copies cf all test reports when strength of concrete is used as a basis for acceptance. Please contact us if you have any .q~.estions or require any additional infommation. Pi==~ nut~£y TXI of approval of the proposed mix designs prior to their use. Failure to notify us prior to first placement ohull constitute acceptance. To ensure that the proper mix designs are ordered, please send a copy of ~h~ l~tt~r, aft. a~ approval, to the above referenced ~roject to be used by the person ordering the concrete for th~s ]ob. SincereLy, TXI Op~z'ations, LP Cus:omer Service Representative Mix #: 0045 Description: 4,50SK ADMIX Strength: 3000 psi @ 28 Days 1 "CS PIERS, GRADE BEAMS Maximum Coarse Aggregate: 1" - #4 CRUSHED STONE Maximum Water/Cement Ratio: 7.11 gal/~ack or 0,631 lbs/lb Cement/Cementitious Content: 4,50 sacks (per cubic yard) AdmiXture: ASTM C-494 Type A or D MATERIAL QUANTITIES PER 1.0 CUBIC YARD AT S.S.D 423 lbs. ASTM C 150 TYPE I CEMENT 1840 lbs. 1" - #4 CRUSHED STONE 1501 lbs. CONCK~T~ SA.ND 267 lbs. or 32.0 Gallons of Water 2.0 to 4.0 oz/cwt of A~TM C-494,Ty~e A Placement Slump: 4.00 + or - 1.00 ~ncnes Mix #: 0046 Description: 5.00SK ADMIX Strength: 3500 psi @ 28 Days 1 "CS PANELS Maximum Coarse Aggregate: I" - ~4 CRUSHED STON~ Maximum Water/Cement Ra=io~ 6.~0 gal/sack or 0.568 ibm/lb Cement/Cementitious Content: 5.00 sacks (per cubic yard) Maximum Placement Slump= ~.00 inches Admixture: ASTM C-494 Type A or D MATERIAL QUANTITIES PER 1.0 CUBIC YARD AT S.S.D 470 lbs, ASTM C 150 TYPE I CEMENT 1.840 lbs. 1" - #4 CRUS~ED STONE 1462 IDs, CONCRET~ SAND 267 lbs. or 32.0 Gallons of Water 2.0 tO 4.00Z/CWt of A~TM C-494 Type A Placement Slump: 4.00 + or - 1.00 inches Mix #: 0047 Description: 5.50SK ADMIX Strength: 4000 psi @ 28 Days 1 "CS SLABS Maximum Coarse Aggregate: 1" - $4 CRUS}{ED STONE Maximum Water/Cement Ratio: 5.82 gal/mack or 0.DI~ lbs/lb Cement/Cementitiou~ Content: 5,50 sacks (per cubic yard) Mawiml,m Wla~me~.t Slumpe E.0O inches Admixture: ASTM C-494 Type A or D MATERIAL QUANTITIES PER i.0 CUBIC YARD AT S.S.D 5~7 lbs. ASTM C 150 TYPE I CEMENT 1840 lbs. l" - #4 CRUSHED STONE 1422 lbs. CONCF~ETE SAND 267 lbs. or 32.0 Gallons of Water 2,0 to 4.0 oz/cw~ of ASTM C-~4 Type A Placement Slump: 4.00 + or - 1.00 inches Mix #: 9643 Description: 5.50SK TYPE A ADMIX/AEA Strength: 4000 psi @ 28 Days 1" CS PAVING Maximum Coarse Aggregate: 1" - $4 CRUSHED STONE Maximum Water/Cement Ratio~ 5.d4 gal/sack or 0.499 l~s/lb Cement/Cementitious Content: 5.50 sacks (per cubic yard) Air EntraininN Agent: AS~M Admixture: ASTM C-494 MATERIAL QUANTITIES PER 1.0 CUBIC YARD AT S.S.D 517 lbs. ASTM C 150 TYPE I CEMENT £840 lbs. ~" - $4 ~KUS~ED STONE 1312 lbs. CONCRETE SAND 258 lbs. or 31.0 Gallons u£ waL~r 2.0 to 4,0 oz/cwt of ASTM C-494 Type A Specified Air Content: 3.0% 6.0% placement ~lump: 4.00 + or - 1.00 inches PUMPING NO'r~.'~ / E/~UQMM~.'NDA'I'£QNS 1. $" minimum dlmm~LNz' lln~ w£th no reduction to smaller lines. 2. Keep rubbor ho~c to a~solute m£nlmum length and plan pipe with as few 90 de~ree angles as possible. ~a'mplmm f~ slump and ~tren~th te~t~ should be taken ~ discharge end of hose for strength guarantee to be valid. 4. To prime DumP.lin~a, a minimum of 8.0 sack grout sho~ld hm used for lubrication. In the case of strength concrete, equivalent strength grout should be used if the qrout remains in the placement. 5. Pump mixes are based on minimum cement content pumped at ground level. AS pump line increases in.l~ngth or height and/or layout configuration changes, addl~/onal cement may be required to a~ur~ stren~tl~ ~ld pu~p'~13zli~y at additional cost to the contractor. 6. TXI cannot COntrol, and lo thoroforo not rcsponmlble for excessive loss of entrained air content when loss occurs as hose. To ensure minimum air loss when pumpins, maintain a continuous flow of concrete through the entire length of pipe and do not subjec~ concrete to free fall. 7. The term "pumpable concrete" refers to concrete which is capable o~ being transported throush an appar'atus which forces concrete to the placing posxtion through a pipeline or hose as long as the recommendations indicated above are followed. The term "pumpable concrete" does not relate to concrete proportioncd in a particular m~%er or cu~L~ini~ a specific type of product. Unless otherwise indicated, when the concrete temperature at point of placement exceeds 90 degrees ~hr~nh~4t, TXI will guarantee the strength performance of the mix design(s) herein submitted up to a maximum placement temperature of 100 degrees Fahrenheit u~ing an ASTM C 494 T~.e.D retarding water-reducer, as long as the concrete is placed wzthzn 75 minutes from batch time. Unless o~herwise indicated, strength o~ plain concrete guaranteed up to a maximum placement temperature of 85 degrees Fahrenheit.. We are enclosing all available back up data for thc referenced mix design(s). If the strength information is not.available, or ~m 4nmuff~.cient, confirm~tlon tests may have to be conducted by your laboratory. Strength of lightweight mix designs v~lid provided s~renGth specimens are cured mn accordance wlth ASTM Test Method ~ 567, as referenced in section 8.1 of ASTM Specification C 330. 3000 i o¢/15/99 04/26/99 04/22/99 ; 0%/22/99 31 ~ o413819~ 10 04/2~/9~ 41 2~ 04/~/9~ 42 04/29/99 z~ 20 04/30/~ 21 04/30/~9 Ub/U'//~ 23 00/07/9~ n~/~/~ 0?/0?/99 43 30 O?/Z6/~ 47 *** Avereges *** Ambient concrete ~1~ (~n) Day ........ Cumul&tive Movi~j $9 64 5,50 N/A ~400 4160 4290 4290 220 51 60 6,~0 N/A 3740 37~0 D720 396~ 396~ 40 ?2 75 6.00 N/A 31~0 34~0 332~ 3805 364~ ~o 70 75 S.25 N/A 3;10 3400 3505 3745 3517 2~0 69 74 ~,50 N/A 3910 ~2~0 4080 3802 3637 340 78 81 5.00 N/A 3220 ~170 3195 3714 3~93 76 96 5.25 N/A 3060 3220 ~Z¢0 3643 3472 160 81 84 S,~0 N/A 4760 ~$20 4690 ~75~ ]675 240 76 79 4,00 N/A 4590 4690 4640 384? 41S7 AO0 89 ~ ~.35 ~/A 5060 ~/~u e~2b ~45 4~52 84 8~ 6.25 N/A 3~40 38~0 3845 393~ 4470 10 ~3 9~ ~,;0 ~/~ ~080 &~30 4&05 ~50 4292 ~o 63 58 6.00 N/A 41~0 3980 4075 3959 4009 190 70 $9 ~,00 N/A 4320 4220 427n ~q~ 415o ~oo 78 60 6.00 N/A 4430 4500 44~ 4002 4203 70 00 61 5,75 N/A ~230 4510 4370 4022 ~217. 280 70 SO 6,~5 N/A 4Z80 3900 4000 4035 4~05 200 75 62 6.00 M/A 4~80 4000 ~140 4031 4197 280 91 64 5,25 N/A 4930 4730 4630 4069 4350 200 Uu ~ ~,0O N/A 4020 3~60 3990 4065 ~320 60 79 93 ~,~0 N/A 4260 4160 42~0 4~72 43~3 100 75 ao 5.00 N/A %0%0 ~99o ~o15 40~ %ol~ hu 75 84 3.~0 N/A 4240 4120 4180 4074 4135 120 T~ ~ 4.00 N/A 4140 %~O ~l~B ~0T~ 98 ae S.00 N/A 2920 3110 302~ 4038 37~3 190 94 80 5,00 N/A 3530 3040 3285 4011 90 93 5,00 N/A 4~20 4200 ¢210 4018 3503 220 92 90 4.00 N/A 3520 3430 347S 4000 3657 90 7G 74 5,20 COMN~ENTARY OF ~TATIST~,~AL EVALUATIQ~ OF CONCRETE DEEI~N RE~LT~ Mix Num: 0045 Strength= 3000 psi ~ 28 Days Paragraph 5.5 oX ACI 318-~ provides that as data becomes available during construction, Lhu a~l~o~lt by which (F'cr) mus~ exceed the specified value of (P'c) may bc reduced, provld=d: (a) 30 or m~w~ te~t re~ult~ are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated i~ ~ccn~d. ance with Section 5.3.1.1, or (b) 15 to 29 test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard devla~on calculated in accordance wit~ Section 5.3.1.2. Th? required average.compressive strength has been ca%culated using a standard devmat=on calculutod ~n accordance wzth ACI 318-89 Section B.3.1.1 or Section 5.3.1.2 and is the larger value of these calculafi4o~m: F'cr = F'c = 3000 = 3664 F'cr ~ F'c = 3000 = 3654 + 1.34(SD) + 1.34( 495.2) + 2.33(SD) - 5b0 + 2.33( 495.2) - 500 ~UMMARY OF STATISTICAL ANALYSIS 28 Day Teat Data Number of Tests .......................... 30 Maximum Value ............................ 4925 p~i Minimum Value ............................ 3015 ps%. Range .................................... 1910 Average Strength ......................... 4000 psi ~a~dard Deviation ....................... 495 psi Required Average.Strength to satisfy minimum Drobabmllty conditions of ACI 318-89 Section 5.3.2,1 ............... 3664 psi Design excess beyond code requirements... 336 N/.ItNtmbe~z 00%8 06/04/99 5 o6/o~/9~ ? o6/o~/99 o6/o~/~ ~/u~/~ o~/o9/~ ~/~/9~ o6/14/99 20 ~ 06/26/;~ 23 061~t9~ ~/~7/~ ~; nK/~/*~ 2? o6!~819~ 2~ ~ o6/2~/99 30 07/0~/~ Number Ambient ConcreCe Slum,(tn) 35 90 6~ 4.00 12 91 70 31 7~ 96 5.00 41 85 92 5.00 3~ 83 87 S.00 31 78 82 4,?~ 35 80 92 4.75 ~b ~ 6~ 4,50 ~5 64 ~2 $.00 31 80 87 4.25 22 95 90 $,00 35 78 72 5.00 $$ ?9 73 5.50 35 ?B 73 5.00 31 74 94 6.50 31 ?2 96 6.00 88 82 6,00 ~8 ~0 8S 4.00 ~2 . 87 g4 $,00 ~8 70 92 5.25 ~ 7q R~ 4.R~ 38 98 66 S,00 18 82 90 5.00 18 79 85 4.50 12 90 90 4.00 of Air PSI 1 ~8~ 2 ~I Avg 'AVerage A-.,-g of 3 N/A 6250 5000 5625 $626 1250 N/A 5170 ~210 5190 5187 5189 40 N/A 4520 4710 4615 5044 4650 190 N/A 4!90 4260 ~225 48~0 4679 N/A &~20 4740 4~80 4863 4540 N/A 5440 5360 5400 4940 4802 80 N/A 5260 ;350 5305 4986 5162 90 N/A 5450 5290 5]?0 $028 5]58 160 N/A 8330 5290 531o 5o5~ 5328 ~/A 5000 'S$30 g26'5 ~07~ ~3~ 530 N/A 4190 t120 4156 4999 4910 70 ~/A ce~o ~76o 47.5 So2~ 4e2e G0 N/A 4380 5290 ¢825 S0o~ 5052 Bgo N/A 4840 6090 5465 $038 S025 1250 N/A 6070 5010 55~0 5067 5277 1060 N/A 4520 4680 4600 S0~l 5202 160 N/A 4340 4560 44~0 S010 ~063 220 N/A 5710 55%0 5625 5041 4892 ~0 N/A 5~;0 ~630 5690 5072 5255 ~0 ~/A ~U ~£U ~UU bUbU b~Ub 'IUU ~/A 4790 ~060 4995 5045 5072 270 N/A 4~00 4SOO 49&~ ~033 49~9 310 N/A 5620 4~00 4960 $030 4877 1320 N/A 5360 5020 5190 50e! 547~ 340 N/A 4G80 5220 S0SO $080 5S03 340 ~/A 5~3o 62~o s2Bo 5087 5173 lo0 N/A 3990 3980 3975 5050 &76~ 10 81 86 5,00 C~~_R¥..O~. STATTSTICAL.EVALUATION OF CONCRETE D~SI~N R~LTE Mix Num: 0046 Strength: 3500 psi ~ 28 Day~ Paragraph 5.5 of ACI 318-95 provides that as data becomes available during con~tru¢~ion, thc amount by which (F'cr) must exceed the specified value of (F'c) may be reduced, prov£dcd: (a) 30 or more test results are ava~h~ and ayahs.ge of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1,1, or (b) lb to 29 test results are available and aVerage o~ test results exceeds that required by Section 5.3.2.1, using = ~L~nd~'d d~vi~Lluu c~luul~&~d in ~u~u~'d~n~u with Section 5.3.1.2. The required average,compressive strength 'has been calculated using a standard devzat~on calculated in accordance with ACI 318-89 Section ~.3.1.1 or Section 5.3.1.2 and is the larger value of these calculations: ~ 3500 = 4191 F'cr ~ ~ 3500 + 1.34(SD) + 1.3%( 515.5) + 2.33(SD) - 500 + 2.33( 515.5) - 500 SUMMARY OF STATISTICAL ANALYSIS 28 Day Test Data Number of Tests ....... 30 Maximum V~lue ............................ 6270 psi Minimum Value ............................ 3975 ps% Range .................................... ~9~ p~ Average Strength ......................... 5050 psi ~tan~ard Deviation ....................... 516 Dsi Required Average Strength to satisfy minimum probability conditions of ACI 318-89 Section 5.3.2.1 ............... 4201 psi Design excess beyond code requirements... 849 psi A 11/15/99 1 02/10/99 40 3 02/i0/99 40 4 02/Z0/9~ 40 5 02/1~/99 40 7 02/~5/99 40 9 02/15/99 40 10 02/15/99 40 1£ 02/&6/~ 40 12 02/16/99 40 14 02/16/99 40 17 04/13/99 19 04/29/99 12 ~o o5/o7/~9 2! 05/07/99 ~2 05/07/g9 2~ 05/07/99 25 06/03/99 40 27 0~/o9/9~ 40 2~ 0e/i6/9~ 43 29 06/18/99 43 30 06/I~/9~ 43 t~anren~el~) ~lacemenu Percenu ......... 2~ ~ ........ Cumu~a~lv~ ~ten~ Concrete SlX(in) o~ ~r PSI i PSI 2 ~I Avg Av~age A,~ of 3 66 74 5,75 ~/A 4~40 4a20 4~.0 4.80 220 64 93 5.50 ~/A ~940 4~90 40;~ 4998 4898 150 67 72 5,25 ~/A S02G 4710 4~65 ~890 4893 70 66 5,50 N/A 6190 6370 6~60 5168 5270 69 68 6.00 N/A 5460 ~990 5015 5243 55~7 55 60 ~,50 N/A 5~90 5250 5410 5266 5968 320 62 61 5.50 N/A 4170 4220 419~ S133 5073 50 6S 65 5.50 N/A 4~O &~U 4~bu blU2 G~2 53 62 5.75 N/A S2E0 5550 5405 5133 4820 290 ~0 ~ 5.00 ~/A 4G~O ~770 ~7~0 D096 ~gP0 O0 57 64 5.50 N/A 4790 45~0 4650 5059 492~ 280 ;$ g3 ~.so ~/A a~o ~9n ~ann ~nns 4~ ~n ;0 62 5,00 N/A 4B50 ~560 4555 ~gTG 4535 10 70 3.00 N/A 4420 &~0 ~495 4~44 4463 ~ 70 6,00 N/A 4650 5010 4830 4937 4627 75 70 6.00 ~A ~650 5010 48~0 49~0 4719 360 88 84 S.00 N/A ~370 52~0 5320 4910 ~767 59 66 3,S0 N/A 5840 4590 5315 49~5 4895 1250 76 8! 4 00 N/A 4200 &lT0 4189 4890 4907 30 bu ,sb ~ uu ~/~ ~10 ~=o ~o 4aa3 ~e~ 5S 65 S,00 N/A 4500 3960 4230 483~ 4235 G0 0~ ~.00 N/~ s600 ;~90 gg~ 4g~o 4~ ~0 89 82 5.00 ~/A ~670 5480 5575 4897 5150 190 qR R4 6.00 N/A 5030 5170 5100 4908 5440 140 75 85 5.o0 N/A 4420 ¢530 449~ 4889 5050 i10 ~ ~9 6,75 ~/~ 46G0 ~80 4520 4876 4698 280 B1 88 ?,00 N/A 4600 %6C0 ~600 4866 4~2 74 88 6.75 N/A 4710 ~890 4800 4864 4640 180 COMM~.~NT~V OF STATISTIO~AL EVALUATION OF CONCRETE Mix Num~ 0047 Strength: 4000 psi · 28 Days Paragraph 5.5 of ACI 318-95 p~'ovid~ ~haL ~ daL~ become~ available durin~ construction, the amount by which (F'cr) must exceed the specified value of (F'c) may be reduced, provided: (a) ~O or more test results are available and average of test results exceeds that required by ~ectiOn 5.3.2.1, using a ~tandard deviation calculatea ~n accordance with Section 5.3.1.1, or (b) 15 to 2~ tes~ results are available and average of ues~ results exceeds that required by Section 5.3.2.1, using ~ ~L~d~'d deviation calculated in accordance with Section 5.3.1.2. The required average compressive strength has ~een calculated u~in~ a s~and~rd deviation calculated in accordance w~o ACI 318-89 Section 5.3.1.1 or Section 5.3.1.2 and is the larger value of these calculations: F'cr = F'c = 4000 = 4695 F'cr = F'c = 4000 + !.34(SD) + 1.34( 2.33 (SD) - 5OO .33 < 518.3) - 500 SUMMAKY OF STATISTICAL ANA~Y~I~ 28 Day Test Data Number of Tests .......................... 30 Msximum Value ............................ 6280 poi Minimum Value ............................ 4!50 psi Range .................................... 21~0 p~i Average Strengt~ ......................... 4864 Standard Deviation ....................... 518 Required Avera~e.S~reng~h ~o satisfy minimum Drobabll~ty conditions O~ ACI 318-89 Section 5.3.2.1 .............. 4708 Design excess beyond code requirements... 156