Loading...
Parks Coppell ABQ-CS 921207 ~;'~g~-~. T£..~aS 75~!? " .... =' ' ...... ' '~':,~ ,~.~ '"~,~vL',~':*"~',a~uL:u'~^~'"'~--: c--%.--.~.,. :~_. December 7. 1992 Mr. Mike Dowdev Dan M. Dowdey & Associates 16250 Dallas Parkway, Suite 100 Dallas, Texas 75248-2684 RE: Mill Creek Estates ; Dear .',,Ir. Dowdev: The City of Coppell has received and reviewed the referenced plans and has the following comments to offer: 1) Need to show curve information on all paving plan sheets, i. e. radius. 2.) On Firelight Way, a wheelchair access across median should be provided. Follow A.D.A. requirements. 3) Need to show location of screening wall and sidewalks along Parkway Blvd. 4) Show proposed development, streets and lots, on Overall Drainage Area Map. 5) Detail all channel profiles and sections. Also, show erosion control protection on slope and pilot channel. 6) A 8" proposed water line on Sheet 2 of Storm Sewer Plans is shown to be inside the 24" minimum clearance requirement. If minimum clearance cannot be met, a concrete encasement must be provided. Address all other utility crossings having the same situation. 7) In profile view of storm sewer plans, show all the proposed wye sizes. 8) On Sheet 5 of storm sewer plans, show how Line "I" will be connected to existing 18" RCP, i.e. show detail. 9) Show all proposed drainage easements on grading plans. There are various other minor comments throughout these plans. Once all comments have been addressed, the revised set of plans should be resubmitted to the City for review. If you should have any questions concerning these comments, please feel free to contact me at .','our convenience. Sincerely, Michael A. Martin E.I.T.